Abstract
With the evolution of m-Health, an increasing number of biomedical sensors will be worn on or implanted in an individual in the future for the monitoring, diagnosis, and treatment of diseases. For the optimization of resources, it is therefore necessary to investigate how to interconnect these sensors in a wireless body area network, wherein security of private data transmission is always a major concern. This paper proposes a novel solution to tackle the problem of entity authentication in body area sensor network (BASN) for m-Health. Physiological signals detected by biomedical sensors have dual functions: (1) for a specific medical application, and (2) for sensors in the same BASN to recognize each other by biometrics. A feasibility study of proposed entity authentication scheme was carried out on 12 healthy individuals, each with 2 channels of photoplethysmogram (PPG) captured simultaneously at different parts of the body. The beat-to-beat heartbeat interval is used as a biometric characteristic to generate identity of the individual. The results of statistical analysis suggest that it is a possible biometric feature for the entity authentication of BASN.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Self-citation
Cited by
Wireless sensor networks for healthcare: A survey
Alemdar, H., & Ersoy, C. (2010) · Computer Networks · doi:10.1016/j.comnet.2010.05.003 · Cited by 1,427
A novel biometrics method to secure wireless body area sensor networks for telemedicine and m-health
Poon, C. C. Y., Zhang, Y.-T., & Bao, S.-D. (2006) · IEEE Communications Magazine · doi:10.1109/mcom.2006.1632652 · Cited by 570
Self-citationWearable and implantable wireless sensor network solutions for healthcare monitoring
Darwish, A., & Hassanien, A. E. (2011) · Sensors · doi:10.3390/s110605561 · Cited by 556
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
Secure stochastic ECG signals based on gaussian mixture model for e-healthcare systems
Wang, W., Wang, H., Hempel, M., Peng, D., Sharif, H., & Chen, H.-H. (2011) · IEEE Systems Journal · doi:10.1109/jsyst.2011.2165597 · Cited by 45
Metadata
- Authors
- Bao, S.-D., Zhang, Y.-T., & Shen, L.-F.
- Venue
- 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
- Publisher
- IEEE
- Published
- 2005
- Volume
- 2005
- Pages
- 2455-2458
- OpenAlex
- W2097689067
- Cited by
- 172
- References
- 1
- FWCI
- 17.86
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiological Signal Based Entity Authentication for Body Area Sensor Networks and Mobile Healthcare Systems. https://app.cochat.ai/papers/10.1109/iembs.2005.1616965
- The paper
- Bao, S.-D., Zhang, Y.-T., & Shen, L.-F. (2005). Physiological Signal Based Entity Authentication for Body Area Sensor Networks and Mobile Healthcare Systems. 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference. https://doi.org/10.1109/iembs.2005.1616965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.