Cited by 77Non-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting MaterialsHemodynamic Monitoring and Therapy

Wearable, Cuff-less PPG-Based Blood Pressure Monitor with Novel Height Sensor

Shaltis, Phillip A., Reisner, Andrew, Asada, H. Harry·2006·2006 International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

A truly wearable non-invasive blood pressure (NIBP) sensor--light-weight, compact, unobstrusive, and essentially unnoticeable to the patient--could revolutionize healthcare delivered beyond the traditional walls of medical facilities, offering new ways to care for patients in their everyday surroundings. This paper presents results from our work towards the development of a self-contained, wearable blood pressure sensor. A PPG-based approach to blood pressure monitoring is presented. The design enables significant miniaturization of traditional oscillometric devices without the need for occlusive circumferential pressures. It will be shown how natural raising and lowering of the arm replaces the need for bulky actuators. Additionally, a dual-accelerometer height sensor that is tetherless is proposed and supported by experimental results.

Integrity signals

Registry

Crossref · 10.1109/iembs.2006.260027

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The PPG blood pressure sensor integrated a novel height sensor based on two MEMS accelerometers for measuring the hydrostatic pressure offset of the PPG sensor relative to the heart.

    “The sensor integrated a novel height sensor based on two MEMS accelerometers for measuring the hydrostatic pressure offset of the PPG sensor relative to the heart.”
  • The mean arterial blood pressure was derived from the PPG sensor output amplitude by taking into account the height of the sensor relative to the heart.

    “The mean arterial blood pressure was derived from the PPG sensor output amplitude by taking into account the height of the sensor relative to the heart.”
  • A self-contained wearable cuff-less photoplethysmographic (PPG) based blood pressure monitor was subsequently developed by the same research group.

    “A self-contained wearable cuff-less photoplethysmographic (PPG) based blood pressure monitor was subsequently developed by the same research group [23].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Shaltis, P. A., Reisner, A., & Asada, H. H.
Affiliations
  • Massachusetts Institute of Technology (US)
  • Massachusetts General Hospital (US)
Venue
2006 International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2006-08
Volume
2006
Pages
908-911
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2147533602
Cited by
77
References
6
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 1 · 2022: 6 · 2021: 1 · 2020: 3 · 2019: 7 · 2018: 4 · 2017: 7 · 2016: 6 · 2015: 5 · 2014: 5 · 2013: 5 · 2012: 6
FWCI
6.05
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
cuffless blood pressure measurement, photoplethysmography, wearable sensors, non-invasive blood pressure
MeSH terms
Acceleration, Blood Pressure Determination, Body Height, Clothing, Equipment Design, Humans, Sensitivity and Specificity, Transducers, Reproducibility of Results, Photoplethysmography, Monitoring, Ambulatory, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review