Ultra short term analysis of heart rate variability for monitoring mental stress in mobile settings.
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the activity of autonomous nervous system (ANS) that may be related to mental stress. For mobile applications, short term ECG measurement may be used for HRV analysis since the conventional five minute long recordings might be inadequately long. Short term analysis of HRV features has been investigated mostly in ECG data from normal and cardiac patients. Thus, short term HRV features may not have any relevance on the assessment of acute mental stress. In this study, we obtained ultra short term HRV features from 24 subjects during baseline stage and Stroop color word test. We validated these HRV features by showing significant differences in HRV features existed between the two stages. Our results indicated that ultra short term analysis of heart rate and RR intervals within 10 s, RMSSD and PNN50 within 30 s, HF within 40 s, LF/HF, normalized LF, and normalized HF within 50 s could be reliably performed for monitoring mental stress in mobile settings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore recordings between 10 and 50 s, according to which HRV parameters are considered, have been proven to be reliable under certain conditions (Salahuddin et al., 2007).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Salahuddin et al., 2007
Citations
Cites
The PHQ-9: Validity of a brief depression severity measure
Kroenke, K., Spitzer, R. L., & Williams, J. B. W. (2001) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2001.016009606.x · Cited by 44,910
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 2×
“EART Rate Variability (HRV) has been traditionally calculated from five minute or 24 hour ECG recordings for the analysis of cardiac diseases [1].”
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277 · cited 1×
“Frequency domain features were calculated by Welch’s averaging method [23].”
MethodAnterior Cingulate Cortex, Error Detection, and the Online Monitoring of Performance
Carter, C. S., Braver, T. S., Barch, D. M., Botvinick, M. M., Noll, D., & Cohen, J. D. (1998) · Science · doi:10.1126/science.280.5364.747 · Cited by 3,273 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodPardo, J. V., Pardo, P. J., Janer, K. W., & Raichle, M. E. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.1.256 · Cited by 1,495 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodHuman cingulate cortex and autonomic control: converging neuroimaging and clinical evidence
Critchley, H. D., Mathias, C. J., Josephs, O., O’Doherty, J., Zanini, S., Dewar, B., Cipolotti, L., Shallice, T., & Dolan, R. J. (2003) · Brain · doi:10.1093/brain/awg216 · Cited by 1,201 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodThe effect of mental stress on heart rate variability and blood pressure during computer work
Hjortskov, N., Riss�n, D., Blangsted, A. K., Fallentin, N., Lundberg, U., & S�gaard, K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1055-z · Cited by 766 · cited 1×
“Mental stress increased sympathetic activity (low frequency HRV) and blood pressure [8] but decreased parasympathetic activity (high frequency HRV) [9, 10].”
BackgroundStressed or Stressed out: What Is the Difference?
McEwen, B. S. (2005) · Journal of Psychiatry and Neuroscience · doi:10.1139/jpn.0540 · Cited by 593 · cited 1×
“The concept of allostasis has been introduced to explain how adaptive processes maintain stability or homeostasis through the production of mediators such as stress hormone, neurotransmitter, and cytokines [7].”
BackgroundForebrain Pathways Mediating Stress-Induced Hormone Secretion
Van de Kar, L. D., & Blair, M. L. (1999) · Frontiers in Neuroendocrinology · doi:10.1006/frne.1998.0172 · Cited by 380 · cited 1×
“In response to stress, the brain activates the secretion of numerous hormones, including corticosterone/cortisol, catecholamine, prolactin, oxytocin, and renin, as a part of the survival mechanism [6].”
BackgroundThe reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307 · cited 1×
“HRV features sensitive to low frequency components of HRV had poor repeatability and cannot be estimated accurately from ECG segments shorter than 10 min [4].”
MethodIsolation of Specific Interference Processing in the Stroop Task: PET Activation Studies
Taylor, S. F., Kornblum, S., Lauber, E. J., Minoshima, S., & Koeppe, R. A. (1997) · NeuroImage · doi:10.1006/nimg.1997.0285 · Cited by 279 · cited 3×
“However, the subjects strongly tend to identify the color that the word names instead of identifying the color of the word [11].”
BackgroundMethodMatthews, S. C., Paulus, M. P., Simmons, A. N., Nelesen, R. A., & Dimsdale, J. E. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.005 · Cited by 265 · cited 2×
“In addition, it was also widely used in various neurological studies [ 11-15 , 25].”
BackgroundMethodRenaud, P., & Blondin, J.-P. (1997) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00049-4 · Cited by 211 · cited 1×
“Thus, the Stroop test has been utilized as a psychological or cognitive stressor that induced emotional responses, heightened autonomic reactivity [16], and increased heart rate and natural killer cell numbers [17].”
MethodMATTHEWS, S. (2004) · NeuroImage · doi:10.1016/s1053-8119(04)00149-1 · Cited by 211
Fensli, R., Gunnarson, E., & Gundersen, T. (2005) · 18th IEEE Symposium on Computer-Based Medical Systems (CBMS'05) · doi:10.1109/cbms.2005.22 · Cited by 192 · cited 1×
“heart monitoring system for high risk cardiac patients [18-20].”
BackgroundReliability and accuracy of heart rate variability metrics versus ECG segment duration
McNames, J., & Aboy, M. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0097-2 · Cited by 141 · cited 2×
“The mean heart rate was more reproducible and could be more accurately estimated from very short segments (less than 1 min) than any of other HRV features [3].”
BackgroundMiddlekauff, H. R., Nguyen, A. H., Negrao, C. E., Nitzsche, E. U., Hoh, C. K., Natterson, B. A., Hamilton, M. A., Fonarow, G. C., Hage, A., & Moriguchi, J. D. (1997) · Circulation · doi:10.1161/01.cir.96.6.1835 · Cited by 101 · cited 1×
“Mental stress increased sympathetic activity (low frequency HRV) and blood pressure [8] but decreased parasympathetic activity (high frequency HRV) [9, 10].”
BackgroundBenschop, R. J., Geenen, R., Mills, P. J., Naliboff, B. D., Kiecolt-Glaser, J. K., Herbert, T. B., van der Pompe, G., Miller, G. E., Matthews, K. A., Godaert, G. L. R., et al. (1998) · Psychosomatic Medicine · doi:10.1097/00006842-199805000-00015 · Cited by 95 · cited 1×
“Thus, the Stroop test has been utilized as a psychological or cognitive stressor that induced emotional responses, heightened autonomic reactivity [16], and increased heart rate and natural killer cell numbers [17].”
MethodAccuracy of ultra-short heart rate variability measures
Thong, T., Li, K., McNames, J., Aboy, M., & Goldstein, B. (2004) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1280405 · Cited by 88 · cited 1×
“Previous studies reported that features that effectively high pass filter the RR interval series were more reliable and could be more accurately estimated from very short segments [2, 3].”
BackgroundPush‐out stress for fibre posts luted using different adhesive strategies
Mazzoni, A., Marchesi, G., Cadenaro, M., Mazzotti, G., Lenarda, R. D., Ferrari, M., & Breschi, L. (2009) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2009.00656.x · Cited by 87
Personal Heart Monitoring and Rehabilitation System using Smart Phones
Leijdekkers, P., & Gay, V. (2006) · 2006 International Conference on Mobile Business · doi:10.1109/icmb.2006.39 · Cited by 69 · cited 1×
“heart monitoring system for high risk cardiac patients [18-20].”
BackgroundDetection of Acute Stress by Heart Rate Variability Using a Prototype Mobile ECG Sensor
Salahuddin, L. B., & Kim, D. (2006) · International Conference on Hybrid Information Technology (ICHIT) · doi:10.1109/ichit.2006.253646 · Cited by 64
Self-citationDetection of Acute Stress by Heart Rate Variability Using a Prototype Mobile ECG Sensor
Salahuddin, L. B., & Kim, D. (2006) · doi:10.1109/ichit.2006.117 · Cited by 49 · cited 5×
“Detection of R peaks was performed in each 10 min segment to generate RR interval records using our previously developed algorithm [21].”
MethodInfluentialSelf-citationDevelopment and Evaluation of a Bluetooth EKG Monitoring Sensor
Proulx, J., Clifford, R., Sorensen, S. D., Lee, D.-J., & Archibald, J. K. (2006) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2006.74 · Cited by 48 · cited 1×
“heart monitoring system for high risk cardiac patients [18-20].”
BackgroundSalahuddin, L. B., Jeong, M. G., & Kim, D. (2007) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/health.2007.381639 · Cited by 29
Self-citationReliability and accuracy of heart rate variability metrics versus ECG segment duration
McNames, J., Thong, T., & Goldstein, B. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279574 · Cited by 18
Bob, P., Šusta, M., Procházková-Večeřová, A., Kukleta, M., Pavlat, J., Jagla, F., & Raboch, J. (2006) · Physiological Research · doi:10.33549/physiolres.930000.55.s1.107 · Cited by 12 · cited 1×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
Method
Research works printed but not linked: 2
- bayevsky, 2002, HRV Analysis under the usage of different electrocardiography systems (Methodical recommendations)
- s?is?ka, 2002, The Stroop Colour-Word Test in Psychology and Biomedicine, Acta Univ Palacki Olomuc Gymn, 32, 45
Cited by
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
“(30) obtained 5 min of resting ECG data from 24 healthy students and noted”
BackgroundInfluentialLaborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
“Furthermore recordings between 10 and 50 s, according to which HRV parameters are considered, have been proven to be reliable under certain conditions (Salahuddin et al., 2007).”
BackgroundReview on Psychological Stress Detection Using Biosignals
Giannakakis, G., Grigoriadis, D., Giannakaki, K., Simantiraki, O., Roniotis, A., & Tsiknakis, M. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2019.2927337 · Cited by 764
“Various studies have used this method to induce stress [44, 64, 90, 109, 116, 133, 151, 154, 186, 187, 189, 192, 205, 209, 216, 238].”
BackgroundMethodHeart Rate Variability in Psychology: A Review of HRV Indices and an Analysis Tutorial
Pham, T., Lau, Z. J., Chen, S. H. A., & Makowski, D. (2021) · Sensors · doi:10.3390/s21123998 · Cited by 480
“Its statistical robustness makes it well-suited for short-term time windows [30,33,49].”
BackgroundShort-term emotion assessment in a recall paradigm
Chanel, G., Kierkels, J. J. M., Soleymani, M., & Pun, T. (2009) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2009.03.005 · Cited by 367
“In (Salahuddin et al., 2007) the authors analyzed the usability of heart rate variability on different time periods and concluded that 50 s of signals are necessary to accurately monitor mental stress in real settings.”
Background
Metadata
- Authors
- Salahuddin, L., Cho, J., Jeong, M. G., & Kim, D.
- Affiliations
- Samsung Electronics (South Korea) (KR)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 4656-4659
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2162033213
- Cited by
- 374
- References
- 27
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 34 · 2023: 35 · 2022: 42 · 2021: 35 · 2020: 24 · 2019: 40 · 2018: 26 · 2017: 17 · 2016: 13 · 2015: 10 · 2014: 9 · 2013: 13 · 2012: 6
- FWCI
- 10.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Samsung
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, psychological stress, mobile health monitoring, Stroop task, RR interval, RMSSD, pNN50, autonomic nervous system, stress measurement
- MeSH terms
- Autonomic Nervous System, Electrocardiography, Heart Rate, Humans, Monitoring, Physiologic, Stress, Psychological, Time Factors, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.