Ultra short term analysis of heart rate variability for monitoring mental stress in mobile settings.
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the activity of autonomous nervous system (ANS) that may be related to mental stress. For mobile applications, short term ECG measurement may be used for HRV analysis since the conventional five minute long recordings might be inadequately long. Short term analysis of HRV features has been investigated mostly in ECG data from normal and cardiac patients. Thus, short term HRV features may not have any relevance on the assessment of acute mental stress. In this study, we obtained ultra short term HRV features from 24 subjects during baseline stage and Stroop color word test. We validated these HRV features by showing significant differences in HRV features existed between the two stages. Our results indicated that ultra short term analysis of heart rate and RR intervals within 10 s, RMSSD and PNN50 within 30 s, HF within 40 s, LF/HF, normalized LF, and normalized HF within 50 s could be reliably performed for monitoring mental stress in mobile settings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore recordings between 10 and 50 s, according to which HRV parameters are considered, have been proven to be reliable under certain conditions (Salahuddin et al., 2007).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Salahuddin et al., 2007
Citations
Cites
The PHQ-9: Validity of a brief depression severity measure
Kroenke, K., Spitzer, R. L., & Williams, J. B. W. (2001) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2001.016009606.x · Cited by 44,910
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 2×
“EART Rate Variability (HRV) has been traditionally calculated from five minute or 24 hour ECG recordings for the analysis of cardiac diseases [1].”
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277 · cited 1×
“Frequency domain features were calculated by Welch’s averaging method [23].”
MethodAnterior Cingulate Cortex, Error Detection, and the Online Monitoring of Performance
Carter, C. S., Braver, T. S., Barch, D. M., Botvinick, M. M., Noll, D., & Cohen, J. D. (1998) · Science · doi:10.1126/science.280.5364.747 · Cited by 3,273 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodPardo, J. V., Pardo, P. J., Janer, K. W., & Raichle, M. E. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.1.256 · Cited by 1,495 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodHuman cingulate cortex and autonomic control: converging neuroimaging and clinical evidence
Critchley, H. D., Mathias, C. J., Josephs, O., O’Doherty, J., Zanini, S., Dewar, B., Cipolotti, L., Shallice, T., & Dolan, R. J. (2003) · Brain · doi:10.1093/brain/awg216 · Cited by 1,201 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodThe effect of mental stress on heart rate variability and blood pressure during computer work
Hjortskov, N., Riss�n, D., Blangsted, A. K., Fallentin, N., Lundberg, U., & S�gaard, K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1055-z · Cited by 766 · cited 1×
“Mental stress increased sympathetic activity (low frequency HRV) and blood pressure [8] but decreased parasympathetic activity (high frequency HRV) [9, 10].”
BackgroundStressed or Stressed out: What Is the Difference?
McEwen, B. S. (2005) · Journal of Psychiatry and Neuroscience · doi:10.1139/jpn.0540 · Cited by 593 · cited 1×
“The concept of allostasis has been introduced to explain how adaptive processes maintain stability or homeostasis through the production of mediators such as stress hormone, neurotransmitter, and cytokines [7].”
BackgroundForebrain Pathways Mediating Stress-Induced Hormone Secretion
Van de Kar, L. D., & Blair, M. L. (1999) · Frontiers in Neuroendocrinology · doi:10.1006/frne.1998.0172 · Cited by 380 · cited 1×
“In response to stress, the brain activates the secretion of numerous hormones, including corticosterone/cortisol, catecholamine, prolactin, oxytocin, and renin, as a part of the survival mechanism [6].”
BackgroundThe reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307 · cited 1×
“HRV features sensitive to low frequency components of HRV had poor repeatability and cannot be estimated accurately from ECG segments shorter than 10 min [4].”
Method
Research works printed but not linked: 2
- bayevsky, 2002, HRV Analysis under the usage of different electrocardiography systems (Methodical recommendations)
- s?is?ka, 2002, The Stroop Colour-Word Test in Psychology and Biomedicine, Acta Univ Palacki Olomuc Gymn, 32, 45
Cited by
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
“(30) obtained 5 min of resting ECG data from 24 healthy students and noted”
BackgroundInfluentialLaborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
“Furthermore recordings between 10 and 50 s, according to which HRV parameters are considered, have been proven to be reliable under certain conditions (Salahuddin et al., 2007).”
BackgroundReview on Psychological Stress Detection Using Biosignals
Giannakakis, G., Grigoriadis, D., Giannakaki, K., Simantiraki, O., Roniotis, A., & Tsiknakis, M. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2019.2927337 · Cited by 764
“Various studies have used this method to induce stress [44, 64, 90, 109, 116, 133, 151, 154, 186, 187, 189, 192, 205, 209, 216, 238].”
BackgroundMethodHeart Rate Variability in Psychology: A Review of HRV Indices and an Analysis Tutorial
Pham, T., Lau, Z. J., Chen, S. H. A., & Makowski, D. (2021) · Sensors · doi:10.3390/s21123998 · Cited by 480
“Its statistical robustness makes it well-suited for short-term time windows [30,33,49].”
BackgroundShort-term emotion assessment in a recall paradigm
Chanel, G., Kierkels, J. J. M., Soleymani, M., & Pun, T. (2009) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2009.03.005 · Cited by 367
“In (Salahuddin et al., 2007) the authors analyzed the usability of heart rate variability on different time periods and concluded that 50 s of signals are necessary to accurately monitor mental stress in real settings.”
BackgroundGunes, H., & Schuller, B. (2013) · Image and Vision Computing · doi:10.1016/j.imavis.2012.06.016 · Cited by 360
“prediction accuracy requires longer-term monitoring [33,34].”
Baek, H. J., Cho, C.-H., Cho, J., & Woo, J.-M. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0104 · Cited by 315
“…standard deviation (SD) of successive NN interval differences (SDSD), and RMSSD had the best performance for ultra-short-term HRV. Salahuddin et al. 13 determined minimum data length required for reliable HRV parameters using ultra-short-term segments randomly sampled from 24-h Holter monitoring…”
InfluentialSelf-citationEmotion representation, analysis and synthesis in continuous space: A survey
Gunes, H., Schuller, B., Pantic, M., & Cowie, R. (2011) · Face and Gesture 2011 · doi:10.1109/fg.2011.5771357 · Cited by 322
“, [42]), while on the other hand obtaining a reliable prediction accuracy requires long(er)-term monitoring [76], [77].”
BackgroundA Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
Shaffer, F., Meehan, Z. M., & Zerr, C. L. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594880 · Cited by 248
Activity-Aware Mental Stress Detection Using Physiological Sensors
Sun, F.-T., Kuo, C., Cheng, H.-T., Buthpitiya, S., Collins, P., & Griss, M. (2012) · Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-642-29336-8_12 · Cited by 292
Reliability of Ultra‐Short ECG Indices for Heart Rate Variability
Nussinovitch, U., Elishkevitz, K. P., Katz, K., Nussinovitch, M., Segev, S., Volovitz, B., & Nussinovitch, N. (2011) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00417.x · Cited by 249
Esco, M. R., & Flatt, A. A. (2014) · PubMed Central · Cited by 372
Castaldo, R., Montesinos, L., Melillo, P., James, C., & Pecchia, L. (2019) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-019-0742-y · Cited by 246
“Unfortunately, this study has been used to support the majority of works related to mental stress detection using ultra-short HRV features [31].”
BackgroundMethodResultInfluentialElectrocardiogram-Based Emotion Recognition Systems and Their Applications in Healthcare—A Review
Hasnul, M. A., Aziz, N. A. A., Alelyani, S., Mohana, M., & Aziz, A. A. (2021) · Sensors · doi:10.3390/s21155015 · Cited by 212
“This feature is represented in the unit of milliseconds (ms) for a standard short-term recording of 5 min [93], and 60 to 240 s for ultra-short term recordings [94,95].”
BackgroundStress Detection Using Wearable Physiological and Sociometric Sensors
Mozos, O. M., Sandulescu, V., Andrews, S., Ellis, D., Bellotto, N., Dobrescu, R., & Ferrandez, J. M. (2017) · International Journal of Neural Systems · doi:10.1142/s0129065716500416 · Cited by 208
“An emerging research topic inside QoLTs includes their potential application to stress and stress-realted illnesses [43,58,63,68,77].”
Li, K. H. C., White, F. A., Tipoe, T., Liu, T., Wong, M. C. S., Jesuthasan, A., Baranchuk, A. M., Tse, G., & Yan, B. P. (2019) · JMIR mhealth and uhealth · doi:10.2196/11606 · Cited by 202
“In addition, mobile phones have also been used in stress classification via the use of night-time HRV data and as a monitoring tool for mental stress in different psychological settings [84,85].”
BackgroundMethodHeart rate variability metrics for fine-grained stress level assessment
Pereira, T., Almeida, P. R., Cunha, J. P. S., & Aguiar, A. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.06.018 · Cited by 175
Activity-Aware Mental Stress Detection Using Physiological Sensors
Sun, F.-T., Kuo, C., Cheng, H.-T., Buthpitiya, S., Collins, P., & Griss, M. (2012) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-642-29336-8_16 · Cited by 154
“First, the HRV features that we used in this study can distinguish between stressed and baseline segments using 60-second windows [23].”
MethodPecchia, L., Castaldo, R., Montesinos, L., & Melillo, P. (2018) · Healthcare Technology Letters · doi:10.1049/htl.2017.0090 · Cited by 135
“Flatt, 2013 [34] RMSSD 55 control 25 † referred to the literature [20, 35]”
BackgroundResultInfluentialDelmastro, F., Martino, F. D., & Dolciotti, C. (2020) · IEEE Access · doi:10.1109/access.2020.2985301 · Cited by 112
“available frames and to allow the extraction of meaningful stress-related HRV features even in short-time windows [70].”
BackgroundFlatt, A. A., & Esco, M. R. (2013) · Journal of Human Kinetics · doi:10.2478/hukin-2013-0071 · Cited by 115
He, J., Li, K., Liao, X., Zhang, P., & Jiang, N. (2019) · IEEE Access · doi:10.1109/access.2019.2907076 · Cited by 114
“As the validity of HRV features with super-short (10 s) windows is still controversial for different statistical methods and stress protocols in literatures [29], [30], SD2, SDNN and pQ were chosen for their good performance with ultrashort windows (usually in minutes) [10].”
BackgroundMultilevel mental stress detection using ultra-short pulse rate variability series
Zubair, M., & Yoon, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101736 · Cited by 114
Detection of mental stress due to oral academic examination via ultra-short-term HRV analysis
Castaldo, R., Xu, W., Melillo, P., Pecchia, L., Santamaria, L., & James, C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591557 · Cited by 103
Comparison of heart rate variability measures for mental stress detection
Boonnithi, S., & Phongsuphap, S. (2011) · Computing in cardiology · Cited by 100
The reality of virtual reality
Schöne, B., Kisker, J., Lange, L., Gruber, T., Sylvester, S., & Osinsky, R. (2023) · Frontiers in Psychology · doi:10.3389/fpsyg.2023.1093014 · Cited by 113
“HRV is conventionally determined beginning at 5 min intervals, especially with respect to the diagnosis of cardiovascular disease (Salahuddin et al., 2007).”
Classification of Drivers' Workload Using Physiological Signals in Conditional Automation
Meteier, Q., Capallera, M., Ruffieux, S., Angelini, L., Khaled, O. A., Mugellini, E., Widmer, M., & Sonderegger, A. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.596038 · Cited by 97
Individuals’ Stress Assessment Using Human-Smartphone Interaction Analysis
Ciman, M., & Wac, K. (2016) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2592504 · Cited by 95
“The development of mobile wearable devices enables to acquire these values, thus, it is possible to continuously monitor psycho-physiological parameters of individuals without affecting their life; letting practitioners being able to constantly monitoring their patients with objective data [11], [12], [13], without re…”
BackgroundMultimodal information improves the rapid detection of mental fatigue
Laurent, F., Valderrama, M., Besserve, M., Guillard, M., Lachaux, J.-P., Martinerie, J. M., & Florence, G. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.007 · Cited by 86
“In a previous study [30], both time-domain (e.”
Zeng, Z., Huang, Z., Leng, K., Han, W., Niu, H., Yu, Y., Ling, Q., Liu, J., Wu, Z., & Zang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02451 · Cited by 78
Golgouneh, A., & Tarvirdizadeh, B. (2019) · Neural Computing and Applications · doi:10.1007/s00521-019-04278-7 · Cited by 83
“Before introducing the extracted features, first we will name these characteristics: • P1: Systolic amplitude [57] • P2: Diastolic amplitude [57] • TP1: Crest time (width of the wave from the beginning of the pulse to the systolic peak) [57] • TP2: Dicrotic wave time (width of the wave from the beginning of the pulse…”
MethodInfluentialMental Stress Assessment Using Ultra Short Term HRV Analysis Based on Non-Linear Method
Lee, S., Hwang, H. B., Park, S., Kim, S., Ha, J. H., Jang, Y., Hwang, S. J., Park, H.-K., Lee, J., & Kim, I. Y. (2022) · Biosensors · doi:10.3390/bios12070465 · Cited by 99
“As HRV analysis of data spanning less than 5 min becomes important in several healthcare applications, ultra-short-term HRV analysis has been actively studied in previous studies of HRV stress assessment using various methods included in mental arithmetic tasks [28], examination stress [11,32], and the Stroop color-wo…”
MethodTowards context-sensitive collaborative media recommender system
Alhamid, M. F., Rawashdeh, M., Osman, H. A., Hossain, M. S., & Saddik, A. E. (2014) · Multimedia Tools and Applications · doi:10.1007/s11042-014-2236-3 · Cited by 73
“Therefore, for the physiological context detection, we simply use the short term analysis of the heart rate variability proposed by [30] to determine if there is the potential of the user being in an elevated stress state, a neutral state, or a relaxed state, as in Fig.”
BackgroundMethodEsco, M. R., Williford, H. N., Flatt, A. A., Freeborn, T. J., & Nakamura, F. Y. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3759-x · Cited by 78
Deep ECG-Respiration Network (DeepER Net) for Recognizing Mental Stress
Seo, W., Kim, N., Kim, S., Lee, C., & Park, S. (2019) · Sensors · doi:10.3390/s19133021 · Cited by 72
“These are typical tasks that have been used to induce stress in previous studies [12,15,17].”
MethodQuality Assessment of Ambulatory ECG Using Wavelet Entropy of the HRV Signal
Orphanidou, C., & Drobnjak, I. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2615316 · Cited by 76
“While the standard recommendation for obtaining reliable HRV measurements has been set at a minimum of 5 min [11], studies have shown that HF components can be satisfactorily analyzed in window sizes as small as 20 s [13].”
BackgroundRADIANT: Better rPPG estimation using signal embeddings and Transformer
Gupta, A. K., Kumar, R., Birla, L., & Gupta, P. (2023) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv56688.2023.00495 · Cited by 88
“Since, it avoids any contact between sensors and skin, it can be used in applications where contact-based PPG methods cannot be used such as, drowsy driver detection [53], deepfake detection [25, 54], face anti-spoofing [4, 5], micro-expression recognition [16], micro-expression spotting [20, 17], lie detection [59] a…”
MethodAhmad, A. H., & Zakaria, R. (2015) · Europe PMC (PubMed Central) · Cited by 108
Szakonyi, B., Vassányi, I., Schumacher, E., & Kósa, I. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00911-6 · Cited by 67
“Such devices are chest belts [13, 22, 33] or ECG-infused clothing [19], wrist bracelets or activity trackers [9, 10, 20, 27], or other portable ECG devices [13, 21].”
BackgroundUltra‐short heart rate variability recording reliability: The effect of controlled paced breathing
Melo, H. M., Martins, T. C., Nascimento, L. M., Hoeller, A. A., Walz, R., & Takase, E. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12565 · Cited by 67
Heart rate variability indices for very short-term (30 beat) analysis. Part 1: survey and toolbox
Smith, A.-L., Owen, H., & Reynolds, K. J. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9471-4 · Cited by 76
Chin, M. S., & Kales, S. N. (2019) · Stress and Health · doi:10.1002/smi.2887 · Cited by 67
Effect of Landscape Microclimates on Thermal Comfort and Physiological Wellbeing
Liu, B., Lian, Z., & Brown, R. D. (2019) · Sustainability · doi:10.3390/su11195387 · Cited by 66
“In the experience period, we used ultra-short-term (3 min) sampling to measure HRV [42,43].”
MethodIs Ultra-Short-Term Heart Rate Variability Valid in Non-static Conditions?
Kim, J. W., Seok, H. S., & Shin, H. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.596060 · Cited by 68
Estimation of Mental Distress from Photoplethysmography
Zangróniz, R., Martínez‐Rodrigo, A., López, M. T., Pastor, J. M., & Fernández‐Caballero, A. (2018) · Applied Sciences · doi:10.3390/app8010069 · Cited by 64
“Thus, temporal features like MENN or SENN have resulted statistically significant in the same context of stress when using ultra-short term analysis of HRV [31].”
BackgroundInfluentialCuffless Deep Learning-Based Blood Pressure Estimation for Smart Wristwatches
Song, K., Chung, K.-Y., & Chang, J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2947103 · Cited by 58
“Since the PPG signal and ECG signal of 20 s are the data size validly enabling to use the feature vector, which is confirmed in the literature [26]–[29], we recorded the two signals for 20 s.”
MethodHeart rate variability indices for very short-term (30 beat) analysis. Part 2: validation
Smith, A.-L., Owen, H., & Reynolds, K. J. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9473-2 · Cited by 62
Flexible and Printed PPG Sensors for Estimation of Drowsiness
Ryu, G., You, J., Kostianovskii, V., Lee, E.-B., Kim, Y., Park, C., & Noh, Y. (2018) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2018.2833477 · Cited by 59
“Although the window segment sizes (10–80 s) are much shorter than those commonly used in the HRV analysis (300 s) [40]–[43], a recent study found that meaningful HRV features could be extracted from short window segments (<60 s) [44].”
MethodMcDonald, A. D., Sasangohar, F., Jatav, A., & Rao, A. H. (2019) · IISE Transactions on Healthcare Systems Engineering · doi:10.1080/24725579.2019.1583703 · Cited by 49
“The overlap was selected based on prior analyses (Salahuddin et al ., 2007), and was intended to reduce the correlation between features in successive windows.”
MethodPhysiological Signal Analysis and Classification of Stress from Virtual Reality Video Game
Ishaque, S., Rueda, A., Nguyen, B., Khan, N., & Krishnan, S. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176110 · Cited by 62
“Salahuddin and other scientists have shown that HRV of ECG can be used to discriminate mental stress stage [9].”
BackgroundShi, K., Steigleder, T., Schellenberger, S., Michler, F., Malessa, A., Lurz, F., Rohleder, N., Ostgathe, C., Weigel, R., & Koelpin, A. (2021) · Scientific Reports · doi:10.1038/s41598-021-81101-1 · Cited by 61
“Although the standard window length of short-time HRV measurements is five minutes, researchers have shown that the calculation of valid HRV parameters is possible for shorter windows 3,32,33 .”
BackgroundPeralta, E., Lázaro, J. M., Bailón, R., Marozas, V., & Gil, E. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab009b · Cited by 61
“…HRV and PRV indices were calculated in short segments with a length in the range of 1–2 min due to the nature of the study (McNames et al 2006, Salahuddin et al 2007, Baek et al 2015, Pecchia et al 2018); stationarity is assumed and a valid segment is considered to be one where there are no…”
MethodMartinez, G. J., Grover, T., Mattingly, S. M., Mark, G. J., D’Mello, S. K., Aledavood, T., Akbar, F., Robles-Granda, P., & Striegel, A. (2022) · JMIR Human Factors · doi:10.2196/33754 · Cited by 61
Kim, D., Seo, Y., Cho, J., & Cho, C.-H. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649244 · Cited by 54
“Fourteen HRV metrics were calculated from the heartbeat interval data of PPG sensors using our previously developed software [16, 17, 18]: mean heart rate (Mean HR), mean heartbeat intervals (Mean RR), standard deviation of the RR-intervals between normal beats (SDNN), coefficient of variation (CV), root mean square o…”
BackgroundMethodSelf-citationExploring Dynamic Difficulty Adjustment Methods for Video Games
Fisher, N., & Kulshreshth, A. K. (2024) · Virtual Worlds · doi:10.3390/virtualworlds3020012 · Cited by 49
“…such as functional near-infrared spectroscopy (fNIRS) to assess task demand [22] and heart rate variability (HRV) for stress detection, linking higher heart rates with increased stress levels [3–5, 23] to The effectiveness of DDA, particularly when grounded in Flow Theory, has been debated.”
BackgroundToward soft real-time stress detection using wrist-worn devices for human workspaces
Khowaja, S. A., Prabono, A. G., Setiawan, F., Yahya, B. N., & Lee, S. (2020) · Soft Computing · doi:10.1007/s00500-020-05338-0 · Cited by 60
“Similarly, in Salahuddin et al. (2007), the Stroop test (Stroop 1935) was used to tempt the emotion and an ECG sensor was employed for recording the stress state.”
MethodOskooei, A., Chau, S., Weiß, J., Sridhar, A., Martínez, M. R., & Michel, B. (2020) · Studies in computational intelligence · doi:10.1007/978-3-030-53352-6_9 · Cited by 54
Stuyck, H., Costa, L. D., Cleeremans, A., & den Bussche, E. V. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2022.10.003 · Cited by 53
Mental fatigue detection using a wearable commodity device and machine learning
Goumopoulos, C., & Potha, N. (2022) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-021-03674-z · Cited by 51
“The length of the time window is determined by features such as the low frequency components which are not reliable for shorter than 5 min time windows (Salahuddin et al. 2007).”
BackgroundFontes, L., Machado, P., Vinkemeier, D., Yahaya, S. W., Bird, J. J., & Ihianle, I. K. (2024) · Sensors · doi:10.3390/s24041096 · Cited by 56
“One approach is measuring HRV using wearable devices such as smartwatches, fitness trackers, and chest straps, allowing continuous and long-term monitoring of stress levels [16,17,20,23,26].”
BackgroundMethodBrisinda, D., Venuti, A., Cataldi, C., Efremov, K., Intorno, E., & Fenici, R. (2014) · Journal of Police and Criminal Psychology · doi:10.1007/s11896-014-9142-5 · Cited by 49
“Further technological development foresees the inclusion of solid-state real-time HRV evaluation and data transmission capable of web-based remote monitoring (Salahuddin et al. 2007; Salahuddin & Kim, 2006).”
BackgroundMethodInfluentialLi, X., Zhu, W., Sui, X., Zhang, A., Chi, L., & Lv, L. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2021.810577 · Cited by 51
“4Hz) domains have found to be associated with stress exposure (26, 27).”
BackgroundSchaaff, K., & Adam, M. T. P. (2013) · International Conference on Affective Computing and Intelligent Interaction and workshops · doi:10.1109/acii.2013.66 · Cited by 55
“While most of these studies dealt with the accuracy and reliability of ultra-short term HRV measures [15]–[17], other studies investigated how far ultra-short term measures can be used to detect mental stress [18], [19].”
BackgroundResultImproving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep
Wang, J., Han, J., Nguyen, V. T., Guo, L., & Guo, C. C. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00249 · Cited by 48
“Previous work has found that test-retest reliability can be improved by removing volumes or subjects with excessive motion, and regressing out motion related artifacts (Schwarz and McGonigle, 2011; Guo et al., 2012; Zuo et al., 2012b; Gorgolewski et al., 2013; Yan et al., 2013; Du et al., 2015).”
BackgroundPrediction of Occupation Stress by Implementing Convolutional Neural Network Techniques
Dalal, S., & Khalaf, O. I. (2021) · Journal of Cases on Information Technology · doi:10.4018/jcit.20210701.oa3 · Cited by 46
Chand, T., Li, M., Jamalabadi, H., Wagner, G., Lord, A., Alizadeh, S., Danyeli, L. V., Herrmann, L., Walter, M., & Şen, Z. D. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00645 · Cited by 45
Gehrke, E. K., Noquez, A., Ranke, P. L., & Myers, M. P. (2018) · Journal of Military Veteran and Family Health · doi:10.3138/jmvfh.2017-0015 · Cited by 43
Landreani, F., Faini, A., Martín-Yebra, A., Morri, M., Parati, G., & Caiani, E. G. (2019) · Sensors · doi:10.3390/s19173729 · Cited by 43
“Accordingly, our aim was to test the feasibility of detecting changes in the ANS state provoked by a mental task by using the beat-to-beat series from short recordings ( 1 min) extracted by a mobile phone m-ACC signal.”
BackgroundInfluentialChen, Y., Lu, W.-A., Pagaduan, J. C., & Kuo, C. (2020) · JMIR mhealth and uhealth · doi:10.2196/18761 · Cited by 45
“Additionally, the RMSSD is recognized as a sensitive parameter to detect autonomic adaptations in response to mental stress [8,35,36] and psychophysiological strain after exercise as well as recovery status during the training period [10,37].”
BackgroundLeaderboard Positions and Stress—Experimental Investigations into an Element of Gamification
Schlömmer, M., Spieß, T., & Schlögl, S. (2021) · Sustainability · doi:10.3390/su13126608 · Cited by 42
“They found that with 10 s RMSSD and with 20 s pNN50, HF and LF HF conclusions about acute psychological stress can be drawn ([40], p.”
BackgroundMOMBAT: Heart rate monitoring from face video using pulse modeling and Bayesian tracking
Gupta, P., Bhowmick, B., & Pal, A. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103813 · Cited by 41
Jungmann, M., Vencatachellum, S., Ryckeghem, D. M. L. V., & Vögele, C. (2018) · JMIR Formative Research · doi:10.2196/10257 · Cited by 45
“rMSSD has been found to be the most reliable metric for ultrashort-term heart rate variability analysis, especially for 10-second intervals under resting conditions [76-80].”
BackgroundA novel multi-kernel 1D convolutional neural network for stress recognition from ECG
Giannakakis, G. A., Trivizakis, E., Tsiknakis, M., & Marias, K. (2019) · International Conference on Affective Computing and Intelligent Interaction Workshops and Demos (ACIIW) · doi:10.1109/aciiw.2019.8925020 · Cited by 40
“Thus, several scientific approaches and methods have been developed for automatic stress recognition based on behavioural patterns [1], facial cues [2], upper body movements [3, 4], biosignals (electroencephalography (EEG) [5], ECG [6], electrodermal activity (EDA) [7]) or multimodal approaches [8, 9].”
BackgroundShi, L., Zhang, Y., Wang, Z., Cheng, X., & Yan, H. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108187 · Cited by 38
Orofacial electromyographic correlates of induced verbal rumination
Nalborczyk, L., Perrone-Bertolotti, M., Baeyens, C., Grandchamp, R., Polosan, M., Spinelli, E., Koster, E. H. W., & Lœvenbruck, H. (2017) · Biological Psychology · doi:10.1016/j.biopsycho.2017.04.013 · Cited by 32
Zeng, C., Zhang, J., Su, Y., Li, S., Wang, Z., Li, Q., & Wang, W. (2024) · Sensors · doi:10.3390/s24134316 · Cited by 39
“For instance, standard short-term HRV assessments involve 5 min electrocardiogram (ECG) recordings, but some markers can be detected based on 1–2 min segments [11].”
BackgroundAssociation of Autonomic Nervous System and EEG Scalp Potential During Playing 2D Grand Turismo 5
Subhani, A. R., Xia, L., & Malik, A. S. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346700 · Cited by 41
Is There an Optimal Autonomic State for Enhanced Flow and Executive Task Performance?
Chin, M. S., & Kales, S. N. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.01716 · Cited by 38
Continuous monitoring of stress on smartphone using heart rate variability
Mayya, S., Jilla, V., Tiwari, V. N., Nayak, M. M., & Narayanan, R. (2015) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2015.7367627 · Cited by 35
“[6] that ultra-short term analysis of HRV within 1 minute duration could be performed to detect stress in mobile settings.”
BackgroundValente, A., Lopes, D. S., Nunes, N., & Esteves, A. (2022) · IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr51125.2022.00034 · Cited by 37
“[17] was followed and a window of 60 seconds was chosen for analysis of time and frequency domain features such as heart rate heart rate (HR), RMSSD and heart rate variability (HRV).”
MethodHow Reliable Are Ultra-Short-Term HRV Measurements during Cognitively Demanding Tasks?
Bernardes, A., Couceiro, R., Medeiros, J., Henriques, J. M. O., Teixeira, C., Simões, M. A., Duraes, J. A., Barbosa, R., Madeira, H., & Carvalho, P. (2022) · Sensors · doi:10.3390/s22176528 · Cited by 35
“In summary, 21 male subjects, ranging from 19 to 40 years, with a median of 22 years, were selected for the experiments after the screening process.”
MethodJiao, Y., Wang, X., Liu, C., Du, G., Zhao, L., Dong, H., Zhao, S., & Liu, Y. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104145 · Cited by 35
Nardelli, M., Greco, A., Bolea, J., Valenza, G., Scilingo, E. P., & Bailón, R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2694999 · Cited by 39
“conditions, such as mental stress [11], [13], [14] or emotional arousal [15], [16].”
BackgroundHirten, R. P., Danieletto, M., Tomalin, L. E., Choi, K. H., Zweig, M., Golden, E., Kaur, S., Helmus, D. S., Biello, A., Pyzik, R., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/31295 · Cited by 35
“Ultrashort term analyses of HRV can be reliably performed to monitor mental health [17].”
BackgroundHybrid SVM classification technique to detect mental stress in human beings using ECG signals
Vanitha, L., & Suresh, G. (2013) · International Conference on Advanced Computing and Communication Systems (ICACCS) · doi:10.1109/icaccs.2013.6938735 · Cited by 32
“Many studies have investigated abnormalities in ANS functioning associated with stress, with HRV as one of the measures shown to be affected (Salahuddin et al., 2007).”
BackgroundValidity of spectral analysis based on heart rate variability from 1‐minute or less ECG recordings
Takahashi, N., Kuriyama, A., Kanazawa, H., Takahashi, Y., & Nakayama, T. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13138 · Cited by 32
A method to quantify autonomic nervous system function in healthy, able-bodied individuals
Debnath, S., Levy, T. J., Bellehsen, M. H., Schwartz, R. M., Barnaby, D. P., Zanos, S. P., Volpe, B. T., & Zanos, T. P. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00075-7 · Cited by 33
“For HRV, we calculated the RMSSD feature for the three tests with intervals longer than 60 seconds, since this HRV measure requires 60 seconds of activity to be calculated accurately (Salahuddin et al., 2007; Baek et al., 2015); heart rate, mean arterial pressure, pupil dilation and EDA measurements were averaged for…”
BackgroundMethodInfluentialLima, R., Chirico, A., Varandas, R. S. P., Gamboa, H. F. S., Gaggioli, A., & Badia, S. B. I. (2024) · Virtual Reality · doi:10.1007/s10055-024-00989-y · Cited by 36
“However, according to recent studies, it is possible to compute ultra-short-term HRV measurements in mobile settings (Salahuddin et al. 2007; Schaaff and Adam 2013).”
Halamová, J., Koróniová, J., Kanovský, M., Túniyová, M. K., & Kupeli, N. (2019) · Research in Psychotherapy Psychopathology Process and Outcome · doi:10.4081/ripppo.2019.358 · Cited by 31
Volpes, G., Barà, C., Busacca, A., Stivala, S. S., Javorka, M., Faes, L., & Pernice, R. (2022) · Sensors · doi:10.3390/s22239149 · Cited by 33
Hemakom, A., Atiwiwat, D., & Israsena, P. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106379 · Cited by 28
Shi, L., Li, Y., Tao, L., Zhang, Y., Jiang, X., Yang, Z., Qi, X., & Qiu, J. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109678 · Cited by 27
Binsch, O., Oudejans, N., van der Kuil, M. N. A., Landman, A., Smeets, M. M. J., Leers, M. P. G., & Smit, A. S. (2022) · Multimedia Tools and Applications · doi:10.1007/s11042-022-14110-5 · Cited by 30
“However, since they also performed better in terms of direction changes, it could be that VR preparation increased cognitive arousal due to increased engagement in the surveillance scenario [55, 76, 84].”
BackgroundContinuous Analysis of Affect from Voice and Face
Güneş, H., Nicolaou, M. A., & Pantić, M. (2011) · Springer eBooks · doi:10.1007/978-0-85729-994-9_10 · Cited by 30
Neuro-Fuzzy Physiological Computing to Assess Stress Levels in Virtual Reality Therapy
Tartarisco, G., Carbonaro, N., Tonacci, A., Bernava, G. M., Arnao, A. A., Crifaci, G., Cipresso, P., Riva, G., Gaggioli, A., Rossi, D. D., et al. (2015) · Interacting with Computers · doi:10.1093/iwc/iwv010 · Cited by 29
Oh, J., Lee, H., & Park, H. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18179136 · Cited by 28
“Salahuddin et al., 2007 [58], Castaldo et al., 2019 [59], Baek et al., 2015 [60], and Marek Malik et al., 1996 [26], verified that standardized LF and HF are common parameters that have valid measures in the extremely short-term measurement of HRV values less than 5 min.”
BackgroundEffects of Changes in Environmental Color Chroma on Heart Rate Variability and Stress by Gender
Oh, J., & Park, H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19095711 · Cited by 28
“Salahuddin et al. (2007) [44], Castaldo et al. (2019) [41], Baek et al. (2015) [45], and Marek Malik et al. (1996) [46] verified that the low frequency (LF) and high frequency (HF) have been normalized.”
BackgroundMethodJiang, M., Mieronkoski, R., Rahmani, A. M., Hagelberg, N. M., Salanterä, S., & Liljeberg, P. (2017) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm.2017.8217798 · Cited by 26
Henry, E. H., Bougard, C., Bourdin, C., & Bringoux, L. (2023) · Transportation Research Part F Traffic Psychology and Behaviour · doi:10.1016/j.trf.2023.06.018 · Cited by 27
Bitemporal seizure spread and its effect on autonomic dysfunction
Page, T., & Rugg‐Gunn, F. J. (2018) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2018.03.016 · Cited by 26
“Seizures were excluded if either the duration of the unitemporal seizure activity or the bitemporal seizure activity was less than 30 seconds thereby providing more reliable data for HRV analysis [17,18] (mean unitemporal seizure duration = 68 seconds, SD = 35; mean bitemporal seizure duration = 79 seconds, SD = 24).”
Method
Metadata
- Authors
- Salahuddin, L., Cho, J., Jeong, M. G., & Kim, D.
- Affiliations
- Samsung Electronics (South Korea) (KR)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 4656-4659
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2162033213
- Cited by
- 374
- References
- 27
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 34 · 2023: 35 · 2022: 42 · 2021: 35 · 2020: 24 · 2019: 40 · 2018: 26 · 2017: 17 · 2016: 13 · 2015: 10 · 2014: 9 · 2013: 13 · 2012: 6
- FWCI
- 10.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Samsung
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, psychological stress, mobile health monitoring, Stroop task, RR interval, RMSSD, pNN50, autonomic nervous system, stress measurement
- MeSH terms
- Autonomic Nervous System, Electrocardiography, Heart Rate, Humans, Monitoring, Physiologic, Stress, Psychological, Time Factors, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.