Mental workload classification using heart rate metrics
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The ability of different short-term heart rate variability metrics to classify the level of mental workload (MWL) in 140 s segments was studied. Electrocardiographic data and event related potentials (ERPs), calculated from electroencephalographic data, were collected from 13 healthy subjects during the performance of a computerised cognitive multitask test with different task load levels. The amplitude of the P300 component of the ERPs was used as an objective measure of MWL. Receiver operating characteristics analysis (ROC) showed that the time domain metric of average interbeat interval length was the best-performing metric in terms of classification ability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962 · cited 2×
“No optimal metric has been presented so far [5].”
BackgroundMethodOn the utility of P3 amplitude as a measure of processing capacity
Kok, A. (2001) · Psychophysiology · doi:10.1017/s0048577201990559 · Cited by 1,766 · cited 1×
“The ERP P300 component amplitude has been found to decrease with an increase in mental workload [8].”
BackgroundThe many metrics of cardiac chronotropy: A pragmatic primer and a brief comparison of metrics
Allen, J. J. B., Chambers, A. S., & Towers, D. N. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2006.08.005 · Cited by 491 · cited 1×
“Several heart rate variability (HRV) metrics have been presented, that provide different information on cardiac chronotropy [4].”
Background
Cited by
Measuring mental workload using physiological measures: A systematic review
Charles, R. L., & Nixon, J. (2019) · Applied Ergonomics · doi:10.1016/j.apergo.2018.08.028 · Cited by 704
The Psychometrics of Mental Workload: Multiple Measures Are Sensitive but Divergent
Matthews, G., Reinerman-Jones, L. E., Barber, D. J., & Abich, J. (2015) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720814539505 · Cited by 265
Monitoring of mental workload levels during an everyday life office-work scenario
Cinaz, B., Arnrich, B., La Marca, R., & Tröster, G. (2013) · Personal and Ubiquitous Computing · doi:10.1007/s00779-011-0466-1 · Cited by 235
“[10] investigated the ability of short-term HRV metrics to discriminate between low and high level of mental workload.”
BackgroundHuman Mental Workload: A Survey and a Novel Inclusive Definition
Longo, L., Wickens, C. D., Hancock, G., & Hancock, P. A. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.883321 · Cited by 222
“The most commonly used electrocardiac and cardiovascular measures are heart rate (HR), hear rate variability (HRV), and blood pressure (BP) (Meshkati, 1988; Henelius et al., 2009).”
Kesedzic, I., Sarlija, M., Bozek, J., Popovic, S., & Cosic, K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3038032 · Cited by 29
Metadata
- Authors
- Henelius, A., Hirvonen, K., Holm, A., Korpela, J., & Muller, K.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 1836-1839
- OpenAlex
- W2151687179
- Cited by
- 70
- References
- 3
- FWCI
- 10.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.