Enhanced EMG signal processing for simultaneous and proportional myoelectric control
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new signal processing scheme is presented for extracting neural control information from the multi-channel surface electromyographic signal (sEMG). The extracted information can be used to proportionally control a multi-degree of freedom (DOF) prosthesis. Four time-domain (TD) features were extracted from the multi-channel sEMG during a series of anisotonic, isometric wrist contractions, which involved simultaneous activations of the three DOF of the wrist. The forces produced at the three wrist DOFs during these contractions were also collected using a customized force sensor. The extracted features and the recorded force signals, as input/target pairs, were then used to train a multilayer perceptron (MLP) neural network. A five-fold cross-validation training/testing method was applied. The resulting performance is a significant improvement over a previously proposed sEMG processing method for the proportional, multi-DOF myoelectric control task.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“mean absolute value (MAV), zero-crossings, slope signs changes (turns) and waveform length contain important control information [8].”
BackgroundMethodSelf-citationA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 1×
“In the current study, the TD feature set was extracted from the multi-channel surface EMG using the standard method [8], [9].”
MethodSelf-citationTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“Recently, the revolutionary targeted muscle reinnervation (TMR) procedure greatly addressed this issue [1], [2].”
Background
Cited by
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Self-citationMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Self-citation
Metadata
- Authors
- Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K., Farina, D., & Parker, P.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 4335-4338
- OpenAlex
- W2126566562
- Cited by
- 52
- References
- 3
- FWCI
- 9.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced EMG signal processing for simultaneous and proportional myoelectric control. https://app.cochat.ai/papers/10.1109/iembs.2009.5332745
- The paper
- Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K., Farina, D., & Parker, P. (2009). Enhanced EMG signal processing for simultaneous and proportional myoelectric control. 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2009.5332745
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.