Cited by 22Neurological disorders and treatmentsEEG and Brain-Computer InterfacesDirection-of-Arrival Estimation Techniques

Application of a null-beamformer to source localisation in MEG data of deep brain stimulation

Mohseni, Hamid R, Kringelbach, Morten L, Smith, Penny Probert, Green, Alexander L, Parsons, Christine E, Young, Katherine S, Brittain, John-Stuart, Hyam, Jonathan A +3 more·2010·2010 Annual International Conference of the IEEE Engineering in Medicine and Biology

Abstract

In this paper, we present an analysis of magnetoencephalography (MEG) signals from a patient with whole-body chronic pain in order to investigate changes in neural activity induced by DBS. The patient is one of the few cases treated using DBS of the anterior cingulate cortex (ACC). Using MEG to reconstruct the neural activity of interest is challenging because of interference to the signal from the DBS device. We demonstrate that a null-beamformer can be used to localise neural activity despite artefacts caused by the presence of DBS electrodes and stimulus pulses. We subsequently verified the accuracy of our source localisation by correlating the predicted DBS electrode positions with their actual positions, previously identified using anatomical imaging. We also demonstrated increased activity in pain-related regions including the pre-supplementary motor area, brainstem periaqueductal gray and medial prefrontal areas when the patient was in pain compared to when the patient experienced pain relief.

Integrity signals

Registry

Crossref · 10.1109/iembs.2010.5627325

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • DBS of the anterior cingulate cortex in chronic pain produced stimulation-specific relief of symptoms accompanied by diffuse functional connectivity changes in the pre-supplementary motor area, brainstem periaqueductal gray matter, rostral anterior cingulate, and medial prefrontal areas.

    “DBS of the anterior cingulate cortex in chronic pain produced stimulation-specific relief of symptoms that was accompanied by diffuse functional connectivity changes in the pre-supplementary motor area, brainstem periaqueductal gray matter, rostral anterior cingulate, and medial prefrontal areas.70”
  • Stimulating the anterior cingulate cortex can be an effective DBS target for a range of conditions, including depression and OCD.

    “which can be an effective DBS target for a range of conditions, including depression and obsessivecompulsive disorder.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Mohseni, H. R., Kringelbach, M. L., Smith, P. P., Green, A. L., Parsons, C. E., Young, K. S., Brittain, J.-S., Hyam, J. A., Schweder, P. M., Stein, J. F., & Aziz, T. Z.
Affiliations
  • John Radcliffe Hospital (GB)
  • University of Oxford (GB)
Venue
2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
Publisher
IEEE
Published
2010-08
Volume
2010
Pages
4120-4123
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2080920443
Cited by
22
References
1
Citations by year
2021: 1 · 2020: 1 · 2019: 4 · 2018: 1 · 2015: 4 · 2014: 2 · 2013: 4 · 2012: 4
FWCI
23.74
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
Funders
Wellcome Trust (WT 088877/Z/09/Z)
Topics
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
Keywords
source localization, magnetoencephalography, deep brain stimulation, anterior cingulate cortex, chronic pain, pre-supplementary motor area, periaqueductal gray, medial prefrontal cortex, analgesia
MeSH terms
Electrodes, Humans, Male, Middle Aged, Magnetoencephalography, Deep Brain Stimulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review