The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Examining the adverse effects of limb position on pattern recognition based myoelectric control
Open accessAbstract
Pattern recognition of myoelectric signals for the control of prosthetic devices has been widely reported and debated. A large portion of the literature focuses on offline classification accuracy of pre-recorded signals. Historically, however, there has been a semantic gap between research findings and a clinically viable implementation. Recently, renewed focus on prosthetics research has pushed the field to provide more clinically relevant outcomes. One way to work towards this goal is to examine the differences between research and clinical results. The constrained nature in which offline training and test data is often collected compared to the dynamic nature of prosthetic use is just one example. In this work, we demonstrate that variations in limb position after training can have a substantial impact on the robustness of myoelectric pattern recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citation
Research works printed but not linked: 10
- 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- 10.1109/TBME.1982.324954 · DOI · Paper page
- 10.1001/jama.2009.116 · DOI · Paper page
- 10.1007/BF02523219 · DOI
- 10.1109/10.398638 · DOI
- 10.1109/TBME.2004.836492 · DOI · Paper page
- 10.1109/TBME.2005.856295 · DOI · Paper page
- 10.1109/IEMBS.2007.4353424 · DOI
- lock, 2005, Design and interactive assessment of continuous multifunction myoelectric control systems
- 10.1016/j.bspc.2007.11.005 · DOI · Paper page
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Self-citationResolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
Self-citationToward improved control of prosthetic fingers using surface electromyogram (EMG) signals
Khushaba, R. N., Kodagoda, S., Takruri, M., & Dissanayake, G. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.02.192 · Cited by 323
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 6337-6340
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2003345831
- Cited by
- 161
- References
- 1
- FWCI
- 24.34
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Examining the adverse effects of limb position on pattern recognition based myoelectric control. https://app.cochat.ai/papers/10.1109/iembs.2010.5627638
- The paper
- Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010). Examining the adverse effects of limb position on pattern recognition based myoelectric control. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.