The DOI matches its Crossref record.
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Abstract
This paper represents an ongoing investigation of dexterous and natural control of upper extremity prostheses using the myoelectric signal. The scheme described within uses a hidden Markov model (HMM) to process four channels of myoelectric signal, with the task of discriminating six classes of limb movement. The HMM-based approach is shown to be capable of higher classification accuracy than previous methods based upon multilayer perceptrons. The method does not require segmentation of the myoelectric signal data, allowing a continuous stream of class decisions to be delivered to a prosthetic device. Due to the fact that the classifier learns the muscle activation patterns for each desired class for each individual, a natural control actuation results. The continuous decision stream allows complex sequences of manipulation involving multiple joints to be performed without interruption. The computational complexity of the HMM in its operational mode is low, making it suitable for a real-time implementation. The low computational overhead associated with training the HMM also enables the possibility of adaptive classifier training while in use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Self-citationMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Metadata
- Authors
- Chan, A. D. C., & Englehart, K. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-01
- Volume
- 52
- Issue
- 1
- Pages
- 121-124
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2149250980
- Cited by
- 343
- References
- 0
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models. https://app.cochat.ai/papers/10.1109/tbme.2004.836492
- The paper
- Chan, A. D. C., & Englehart, K. B. (2005). Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.836492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.