Characterization of gait abnormalities in Parkinson's disease using a wireless inertial sensor system
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Gait analysis is important in diagnosing and evaluating certain neurological diseases such as Parkinson's disease (PD). In this paper, we show the ability of our wireless inertial sensor system to characterize gait abnormalities in PD. We obtain physical features of pitch, roll, and yaw rotations of the foot during walking, use principal component analysis (PCA) to select features, and use the support vector machine (SVM) method to create a classification model. In the binary classification task of detecting the presence of PD by distinguishing between PD and control subjects, the model performs with over 93% sensitivity and specificity, and 97.7% precision. Using a cost-sensitive learner to reflect the different costs associated with misclassifying PD and control subjects, performance of 100% specificity and precision is achieved, while maintaining sensitivity of close to 89%. In the multi-class classification task of characterizing parkinsonian gait by distinguishing among PD with significant gait disturbance, PD with no significant gait disturbance, and control subjects, 91.7% class recall for control subjects is achieved and the model performs with 84.6% precision for PD subjects with significant gait disturbance. The features selected for this classification task indicate the features of gait that are principal in discriminating gait abnormalities due to PD compared to a normal gait. These results demonstrate the ability of our wireless inertial sensor system to successfully detect the presence of PD based on physical features of gait and to identify the specific features that characterize parkinsonian gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“In Parkinson’s disease (PD), SVM has been used to estimate the severity of tremor, bradykinesia, and dyskinesia [ 1 ].”
Method
Cited by
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Machine Learning for the Diagnosis of Parkinson's Disease: A Review of Literature
Mei, J., Desrosiers, C., & Frasnelli, J. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.633752 · Cited by 401
On-Shoe Wearable Sensors for Gait and Turning Assessment of Patients With Parkinson's Disease
Mariani, B., Jiménez, M. C., Vingerhoets, F. J. G., & Aminian, K. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2227317 · Cited by 278
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
Caramia, C., Torricelli, D., Schmid, M., Munoz-Gonzalez, A., Gonzalez-Vargas, J., Grandas, F., & Pons, J. L. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2865218 · Cited by 243
Metadata
- Authors
- Tien, I., Glaser, S. D., & Aminoff, M. J.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 3353-3356
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2002206292
- Cited by
- 60
- References
- 1
- FWCI
- 12.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of gait abnormalities in Parkinson's disease using a wireless inertial sensor system. https://app.cochat.ai/papers/10.1109/iembs.2010.5627904
- The paper
- Tien, I., Glaser, S. D., & Aminoff, M. J. (2010). Characterization of gait abnormalities in Parkinson's disease using a wireless inertial sensor system. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.