The DOI matches its Crossref record.
Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach
Abstract
This paper introduces a new approach, based on the average motor supply current Park's vector monitoring, for diagnosing voltage source inverter faults in variable speed AC drives. Both simulation and laboratory tests results demonstrate the effectiveness of the proposed on-line diagnostic technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 7
- marques cardoso, 1997, Converter fault diagnosis in variable speed dc drives, by park's vector approach, IEEE International Symposium on Industrial Electronics, 2, 497, 10.1109/ISIE.1997.649000 · doi:10.1109/isie.1997.649000
- marques cardoso, 1996, semi-converter fault diagnosis in dc motor drives, by park's vector approach, Proceedings of 6th International Conference on Power Electronics and Variable Speed Drives, 93, 10.1049/cp:19960894 · DOI
- mendes, 1998, voltage source inverter fault diagnosis in variable speed ac drives, by park's vector approach, Seventh International Conference on Power Electronics and Variable Speed Drives (IEE Conf Publ No 456), 538, 10.1049/cp:19980607 · DOI
- mendes, 1998, Fault Diagnosis in a Rectifier-Inverter System used for Speed Control of Three-Phase Induction Motors
- 10.1109/28.297920 · DOI · Paper page
- 10.1109/41.303793 · DOI
- 10.1109/41.605620 · DOI
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [249] the motor supply current PVA is proposed for the VSI short-circuit and open switch fault diagnosis in variable speed AC drives.”
BackgroundMethodFault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
Metadata
- Authors
- Mendes, A. M. S., & Marques Cardoso, A. J.
- Venue
- IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272)
- Publisher
- IEEE
- Published
- 2003-01-20
- Pages
- 704-706
- OpenAlex
- W2165411814
- Cited by
- 213
- References
- 0
- FWCI
- 5.92
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach. https://app.cochat.ai/papers/10.1109/iemdc.1999.769220
- The paper
- Mendes, A. M. S., & Marques Cardoso, A. J. (2003). Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach. IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272). https://doi.org/10.1109/iemdc.1999.769220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.