CoChat

Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach

Mendes, A.M.S., Marques Cardoso, A.J. · 2003 · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272)
Cited by 213

The DOI matches its Crossref record.

Abstract

This paper introduces a new approach, based on the average motor supply current Park's vector monitoring, for diagnosing voltage source inverter faults in variable speed AC drives. Both simulation and laboratory tests results demonstrate the effectiveness of the proposed on-line diagnostic technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iemdc.1999.769220

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 7

  1. marques cardoso, 1997, Converter fault diagnosis in variable speed dc drives, by park's vector approach, IEEE International Symposium on Industrial Electronics, 2, 497, 10.1109/ISIE.1997.649000 · doi:10.1109/isie.1997.649000
  2. marques cardoso, 1996, semi-converter fault diagnosis in dc motor drives, by park's vector approach, Proceedings of 6th International Conference on Power Electronics and Variable Speed Drives, 93, 10.1049/cp:19960894 · DOI
  3. mendes, 1998, voltage source inverter fault diagnosis in variable speed ac drives, by park's vector approach, Seventh International Conference on Power Electronics and Variable Speed Drives (IEE Conf Publ No 456), 538, 10.1049/cp:19980607 · DOI · Paper page
  4. mendes, 1998, Fault Diagnosis in a Rectifier-Inverter System used for Speed Control of Three-Phase Induction Motors
  5. 10.1109/28.297920 · DOI · Paper page
  6. 10.1109/41.303793 · DOI
  7. 10.1109/41.605620 · DOI

Cited by

Metadata

Authors
Mendes, A. M. S., & Marques Cardoso, A. J.
Venue
IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272)
Publisher
IEEE
Published
2003-01-20
Pages
704-706
OpenAlex
W2165411814
Cited by
213
References
0
FWCI
5.92
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.