Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach
The DOI matches its Crossref record.
Abstract
This paper introduces a new approach, based on the average motor supply current Park's vector monitoring, for diagnosing voltage source inverter faults in variable speed AC drives. Both simulation and laboratory tests results demonstrate the effectiveness of the proposed on-line diagnostic technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 7
- marques cardoso, 1997, Converter fault diagnosis in variable speed dc drives, by park's vector approach, IEEE International Symposium on Industrial Electronics, 2, 497, 10.1109/ISIE.1997.649000 · doi:10.1109/isie.1997.649000
- marques cardoso, 1996, semi-converter fault diagnosis in dc motor drives, by park's vector approach, Proceedings of 6th International Conference on Power Electronics and Variable Speed Drives, 93, 10.1049/cp:19960894 · DOI
- mendes, 1998, voltage source inverter fault diagnosis in variable speed ac drives, by park's vector approach, Seventh International Conference on Power Electronics and Variable Speed Drives (IEE Conf Publ No 456), 538, 10.1049/cp:19980607 · DOI · Paper page
- mendes, 1998, Fault Diagnosis in a Rectifier-Inverter System used for Speed Control of Three-Phase Induction Motors
- 10.1109/28.297920 · DOI · Paper page
- 10.1109/41.303793 · DOI
- 10.1109/41.605620 · DOI
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
“9) Average Current Park’s Vector Approach [ 3 ]: In this method, the fault occurrence is related to the average current Park’s Vector modulus.”
BackgroundMethodInfluentialFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [249] the motor supply current PVA is proposed for the VSI short-circuit and open switch fault diagnosis in variable speed AC drives.”
BackgroundMethodFault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Self-citationOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Self-citationJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 264
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212
“The use of currents average values calculation was successfully applied to the Park’s Vector approach [20], presenting however problems regarding the tuning effort, load dependency, and generation of false alarm issues.”
MethodFreire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167
“The average current Park’s vector approach was introduced in [5].”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. (2008) · 2008 IEEE Industry Applications Society Annual Meeting · doi:10.1109/08ias.2008.349 · Cited by 160
“1) Park’s Vector Method [3] In this method, open-circuit fault detection and defect transistor localization are accomplished by calculating the position of the current trajectory’s midpoint, which is the mean value of the ac current space vector over one period.”
MethodInfluentialA hybrid diagnosis method for inverter open-circuit faults in PMSM drives
Zhang, Z., Luo, G., Zhang, Z., & Tao, X. (2020) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2020.00023 · Cited by 39
“Among them, signal analysis method was the first broadly applied method [4] [5] [6].”
Method
Metadata
- Authors
- Mendes, A. M. S., & Marques Cardoso, A. J.
- Venue
- IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272)
- Publisher
- IEEE
- Published
- 2003-01-20
- Pages
- 704-706
- OpenAlex
- W2165411814
- Cited by
- 213
- References
- 0
- FWCI
- 5.92
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.