Cited by 9Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignWireless Body Area Networks

An inductively powered CMOS multichannel bionic neural link for peripheral nerve function restoration

Ng, Kian Ann, Liu, Xu, Zhao, Jianming, Xuchuan, Li, Yen, Shih-Cheng, Je, Minkyu, Xu, Yong Ping, Tan, Ter Chyan·2012·2012 IEEE Asian Solid State Circuits Conference (A-SSCC)

Abstract

This paper describes a inductively powered multichannel bionic neural link (BNL) system-on-chip (SOC) for peripheral nerve function restoration. The BNL-SOC consists of 8 neural recording and 4 stimulation channels, and is implemented in a 0.35-μm CMOS technology. Full function of the BNL has been demonstrated with in-vivo animal experiments. The entire BNL SOC consumes 1.5mW and operates under a 3V supply with an external +/-9V multichannel stimulation output driver.

Integrity signals

Registry

Crossref · 10.1109/ipec.2012.6522655

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • It is common for multiple amplifier channels to share a single ADC or output driver in a time-multiplexed sequence.

    “For example, it is common for multiple amplifier channels to share a single ADC or output driver in a time-multiplexed sequence [1, 51, 73, 94].”
  • Recent works using the telescopic cascode OTA achieved consistently low NEF values below 2.6.

    “Recent works [94, 149], which used the telescopic cascode OTA, achieved consistently low NEF values below 2.6.”
  • Advances in IC design and fabrication now allow neural recording systems to include wireless telemetry for data and sometimes wireless power transfer.

    “With continuous improvements in IC design and fabrication technology, IC neural recording systems can be now integrated with wireless telemetry for data and, in some cases, wireless power transfer [67, 94].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ng, K. A., Liu, X., Zhao, J., Xuchuan, L., Yen, S.-C., Je, M., Xu, Y. P., & Tan, T. C.
Affiliations
  • National University of Singapore (SG)
  • Institute of Microelectronics (SG)
  • National University Hospital (SG)
Venue
2012 IEEE Asian Solid State Circuits Conference (A-SSCC)
Publisher
IEEE
Published
2012-12
Pages
181-184
OpenAlex
W2056248766
Cited by
9
References
4
Citations by year
2025: 1 · 2021: 1 · 2019: 1 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 1
FWCI
2.45
Type
conference paper
Language
en
Open access
closed
Locations
  • IEEE Asian Solid-State Circuits Conference (A-SSCC) (publishedVersion)
  • National University of Singapore (submittedVersion)
Funders
National University of Singapore
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
inductive power transfer, multichannel neural recording, neurostimulation, system-on-chip, CMOS integrated circuit, implantable neural interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review