The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Power assist control for walking aid with HAL-3 based on EMG and impedance adjustment around knee joint
Abstract
This paper describes the power assist control for walking aid based on EMG and impedance adjustment with HAL-3 we have developed. Virtual torque derived from EMG is adopted as a basic control method, and the motion assist control as to operator's intention can be realized by this method. And we suggest the impedance adjustment around knee joint for more effective power assist control. Experiments for simple motion and walking motion were performed to verify the proposed approach, with impedance parameters found by RLS (recursive least square) method. The evaluation of assisted motion was done by a calculation based on EMG in nearly proportion to the operator's muscle force. The results showed the amplitudes of EMG were reduced significantly, the operator was able to swing the leg lighter by reducing the inertia around knee, and the strain of knee in foot-grounding could be alleviated by adding the stiffness to joint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
EMG-based Prototype Powered Assistive System for Walking Aid
Okamura, J. (1999) · Medical Entomology and Zoology · Cited by 60
Cited by
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Self-citationIntention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Self-citationPower assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381
Self-citationReview of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Metadata
- Authors
- Lee, S., & Sankai, Y.
- Venue
- IEEE/RSJ International Conference on Intelligent Robots and System
- Publisher
- IEEE
- Published
- 2003-06-25
- Volume
- 2
- Pages
- 1499-1504
- OpenAlex
- W2104536749
- Cited by
- 291
- References
- 3
- FWCI
- 13.36
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.