An international intercomparison of THz time-domain spectrometers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The paper will present the results of an international multi-lab study comparing results obtained by THz time-domain spectroscopy on a set of standard materials. Measurements of refractive indices and absorption coefficients reported by participants are collated and analyzed in relation to types of system used and the measurement technique. Best practice guidelines are recommended. The obtained data on optical constants of the materials studied are used to arrive at the best estimated values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Research works printed but not linked: 7
- jin, 2006, J Korean Phys Soc, 49, 513
- 10.1063/1.3549120 · DOI · Paper page
- 10.1364/AO.12.000398 · DOI · Paper page
- peters, 1998, Far infrared absorption of Czochralski germanium and silicon, SPIE, 3424, 277-786x/98
- 10.1088/0022-3727/10/4/015 · DOI
- 10.1364/AO.47.003254 · DOI · Paper page
- d'angelo, 2014, Opt Exp, 22, 12477
Cited by
Terahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410
Phase Retrieval in Terahertz Time-Domain Measurements: a 'how to' Tutorial
Jepsen, P. U. (2019) · Journal of Infrared, Millimeter and Terahertz Waves · doi:10.1007/s10762-019-00578-0 · Cited by 114
Metrology State-of-the-Art and Challenges in Broadband Phase-Sensitive Terahertz Measurements
Naftaly, M., Clarke, R. G., Humphreys, D. A., & Ridler, N. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2644108 · Cited by 49
Self-citationLin, H., Burton, O. J., Engelbrecht, S., Tybussek, K.-H., Fischer, B. M., & Hofmann, S. (2020) · Applied Physics Letters · doi:10.1063/1.5135644 · Cited by 31
“The slight discrepancy may be due to sample surface related imperfections, leading to scattering losses and measurement using a focused beam as opposed to a collimated beam [25].”
BackgroundThe dotTHz Project: A Standard Data Format for Terahertz Time-Domain Data
Lee, J., Leung, C. K., Ma, M., Ward-Berry, J., Santitewagun, S., & Zeitler, J. A. (2023) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-023-00947-w · Cited by 28
Metadata
- Authors
- Naftaly, M.
- Venue
- 2016 41st International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz)
- Publisher
- IEEE
- Published
- 2016-09
- Pages
- 1-2
- OpenAlex
- W2566795605
- Cited by
- 25
- References
- 1
- FWCI
- 4.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An international intercomparison of THz time-domain spectrometers. https://app.cochat.ai/papers/10.1109/irmmw-thz.2016.7758763
- The paper
- Naftaly, M. (2016). An international intercomparison of THz time-domain spectrometers. 2016 41st International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz). https://doi.org/10.1109/irmmw-thz.2016.7758763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.