Issues in the haptic display of tool use
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Our group is interested in using haptic display for training tool use. Applications include training doctors to use tools during surgery, and training astronauts to use tools during EVA. This paper describes some of the challenges of creating realistic haptic perceptions of tool use. Many of these challenges stem from the importance of unilateral constraints during tool use. Unilateral constraints occur whenever rigid bodies collide, resisting the interpenetration of the bodies, but not holding the bodies together. To identify unilateral constraints, a tool/environment simulation must perform collision detection. To respond properly to a collision, the simulation must estimate the forces that ensue, and integrate the equations of motion. All of these computations must occur in real time, and the simulation as a whole must be stable (to ensure the user's safety). Approaches to these problems are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1987 american control conference
(1987) · IEEE Control Systems Magazine · doi:10.1109/mcs.1987.1105260 · Cited by 1,402
Factors affecting the Z-Width of a haptic display
Colgate, J. E., & Brown, J. M. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351077 · Cited by 635
Self-citationPassivity of a class of sampled-data systems: Application to haptic interfaces
Colgate, J. E., & Schenkel, G. G. (1997) · Journal of Robotic Systems · doi:10.1002/(sici)1097-4563(199701)14:1<37::aid-rob4>3.0.co;2-v · Cited by 490
Self-citationFeeling and seeing: issues in force display
Minsky, M., Ming, O.-Y., Steele, O., Brooks, F. P., & Behensky, M. (1990) · Proceedings of the 1990 symposium on Interactive 3D graphics - SI3D '90 · doi:10.1145/91385.91451 · Cited by 397
A modeling system based on dynamic constraints
Barzel, R., & Barr, A. H. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378509 · Cited by 309
Salcudean, S. E., & Vlaar, T. D. (1997) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2801204 · Cited by 178
Perceptual decomposition of virtual haptic surfaces
Rosenberg, L. B., & Adelstein, B. D. (1993) · doi:10.1109/vrais.1993.378264 · Cited by 92
Cited by
Time-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
Stable haptic interaction with virtual environments
Adams, R. J., & Hannaford, B. (1999) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.768179 · Cited by 646
Haptics in virtual environments: Taxonomy, research status, and challenges
Srinivasan, M. A., & Basdogan, C. (1997) · Computers & Graphics · doi:10.1016/s0097-8493(97)00030-7 · Cited by 559
Haptic rendering: introductory concepts
Salisbury, K., Conti, F., & Barbagli, F. (2004) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2004.1274058 · Cited by 463
STRANDS: Interactive Simulation of Thin Solids using Cosserat Models
Pai, D. K. (2002) · Computer Graphics Forum · doi:10.1111/1467-8659.00594 · Cited by 317
Fast Continuous Collision Detection between Rigid Bodies
Redon, S., Kheddary, A., & Coquillart, S. (2002) · Computer Graphics Forum · doi:10.1111/1467-8659.00587 · Cited by 266
Haptics in Robot-Assisted Surgery: Challenges and Benefits
Enayati, N., De Momi, E., & Ferrigno, G. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2538080 · Cited by 252
“[61] and Zilles and Salisbury [62].”
Haptic Palpation for Medical Simulation in Virtual Environments
Ullrich, S., & Kuhlen, T. (2012) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2012.46 · Cited by 196
“Our approach is loosely related to virtual coupling [11] and the god-object proxy [45] and works as follows.”
MethodControl law design for haptic interfaces to virtual reality
Adams, R. J., & Hannaford, B. (2002) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.974333 · Cited by 172
“The use of an artificial coupling between the haptic display and the virtual environment was first proposed by Colgate et. al. [ 10 ].”
Large-Scale Experimental Verification of Semiactive Control through Real-Time Hybrid Simulation
Christenson, R., Lin, Y. Z., Emmons, A., & Bass, B. (2008) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2008)134:4(522 · Cited by 168
The design and testing of a force feedback dental simulator
Thomas, G., Johnson, L., Dow, S., & Stanford, C. (2001) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00089-4 · Cited by 73
“An example of such a solution might be the Phantom (SensAble Technologies), which provides forces along the x, y, and z axes as well as passive degrees of freedom for roll, pitch and yaw.”
BackgroundInfluentialEvaluation of a Virtual Reality Percutaneous Nephrolithotomy (PCNL) Surgical Simulator
Sainsbury, B., Łącki, M., Shahait, M., Goldenberg, M., Baghdadi, A., Cavuoto, L., Ren, J., Green, M., Lee, J., Averch, T. D., et al. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2019.00145 · Cited by 37
“Since the haptic devices are intrinsically unstable, the simulation uses a virtual coupling to aid in stabilization of the simulated interactions (Colgate et al., 1995; Colgate and Schenkel, 1997).”
Background
Metadata
- Authors
- Colgate, J. E., Stanley, M. C., & Brown, J. M.
- Venue
- Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots
- Publisher
- IEEE Comput. Soc. Press
- Published
- 2002-11-19
- Volume
- 3
- Pages
- 140-145
- OpenAlex
- W2144415816
- Cited by
- 404
- References
- 7
- FWCI
- 42.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.