CoChat

An improved quaternion-based Kalman filter for real-time tracking of rigid body orientation

Xiaoping Yun, Lizarraga, M., Bachmann, E.R., McGhee, R.B. · 2004 · Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453)
Cited by 100

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This paper presents an improved Kalman filter for real-time tracking of human body motions. An earlier version of the filter was presented at IROS 2001. Since then, the filter has been substantially improved. Real-time tracking of rigid body orientation is accomplished using the MARG (magnetic, angular rate, and gravity) sensors. A MARG sensor measures the three-dimensional local magnetic field, three-dimensional angular rate, and three-dimensional acceleration. A Kalman filter is designed to process measurements provided by the MARG sensors, and to produce real-time orientation represented in quaternions. There are many design decisions as related to choice of state vectors, output equations, process model, etc. The filter design presented in this paper utilizes the Gauss-Newton method for parameter optimization in conjunction with Kalman filtering. The use of the Gauss-Newton method, particularly the reduced-order implementation introduced in the paper, significantly simplifies the Kalman filter design, and reduces computational requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iros.2003.1248787

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Yun, X., Lizarraga, M., Bachmann, E. R., & McGhee, R. B.
Venue
Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453)
Publisher
IEEE
Published
2004-03-30
Volume
2
Pages
1074-1079
OpenAlex
W2152607034
Cited by
100
References
3
FWCI
8.46
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.