The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Shoulder and Elbow Joint Angle Tracking With Inertial Sensors
Abstract
Wearable inertial systems have recently been used to track human movement in and outside of the laboratory. Continuous monitoring of human movement can provide valuable information relevant to individuals' level of physical activity and functional ability. Traditionally, orientation has been calculated by integrating the angular velocity from gyroscopes. However, a small drift in the measured velocity leads to increasing integration error over time. To compensate that drift, complementary data from accelerometers are normally fused into tracking systems using the Kalman or extended Kalman filter. In this study, we combine kinematic models designed for control of robotic arms with state-space methods to continuously estimate the angles of human shoulder and elbow using two wearable inertial measurement units. We use the unscented Kalman filter to implement the nonlinear state-space inertial tracker. Shoulder and elbow joint angles obtained from 8 subjects using our inertial tracker were compared to the angles obtained from an optical-tracking reference system. On average, there was an RMS angle error of less than 8° for all shoulder and elbow angles. The average correlation coefficient for all movement tasks among all subjects was r ≥ 0.95 . This agreement between our inertial tracker and the optical reference system was obtained for both regular and fast-speed movement of the arm. The same method can be used to track movement of other joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
An Overview of Existing Methods and Recent Advances in Sequential Monte Carlo
Cappe, O., Godsill, S. J., & Moulines, E. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.893250 · Cited by 1,009
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Yun, X., & Bachmann, E. R. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886270 · Cited by 569
Motion tracking: no silver bullet, but a respectable arsenal
Welch, G., & Foxlin, E. (2002) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2002.1046626 · Cited by 535
Wearable Robots: Biomechatronic Exoskeletons
(2008) · Wiley eBooks · doi:10.1002/9780470987667 · Cited by 517
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356
Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Roetenberg, D., Slycke, P. J., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889184 · Cited by 334
Xiaoping, Y., Bachmann, E. R., & McGhee, R. B. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.911646 · Cited by 320
Cited by
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329
Continuous Monitoring of Turning in Patients with Movement Disability
El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L. (2013) · Sensors · doi:10.3390/s140100356 · Cited by 258
Self-citationWearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
Metadata
- Authors
- El-Gohary, M., & McNames, J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-09
- Volume
- 59
- Issue
- 9
- Pages
- 2635-2641
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1968740942
- Cited by
- 264
- References
- 24
- FWCI
- 21.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shoulder and Elbow Joint Angle Tracking With Inertial Sensors. https://app.cochat.ai/papers/10.1109/tbme.2012.2208750
- The paper
- El-Gohary, M., & McNames, J. (2012). Shoulder and Elbow Joint Angle Tracking With Inertial Sensors. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2208750
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.