Detection Threshold and Mechanical Impedance of the Hand in a Pen-Hold Posture
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We report position and force detection thresholds for sinusoidal waveforms in the frequency range 10-500 Hz delivered through a stylus. The participants were required to hold the stylus in a way similar to that of holding the stylus of a force-feedback device. A minishaker moved the stylus along its length so that the majority of vibrations were presented tangentially to the skin of the hand. The measured position thresholds decreased initially with an increasing stimulus frequency and formed a U-shaped curve in the high frequency region. The thresholds of high frequency vibrations were lower than those reported previously for vibrations that were perpendicular to the skin, but were similar to the thresholds reported earlier using vibrations that were tangential to the skin. A similar force threshold curve was obtained using a force sensor attached to one end of the stylus. Mechanical impedance of the skin derived from velocity estimates and force measurements indicated that the skin and tissues in the hand holding the stylus can be modeled with mass-, damper- and spring-like elements. A comparison of the mechanical impedance from the present study with those reported previously showed similar results for vibrations delivered in the tangential and normal directions to the skin
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937 · cited 10×
“Our results are compared to those reported in [6] and [8].”
BackgroundResultInfluentialDetection of Vibration Transmitted Through an Object Grasped in the Hand
Brisben, A. J., Hsiao, S. S., & Johnson, K. O. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1548 · Cited by 259 · cited 9×
“Our results are compared to those reported in [6] and [8].”
BackgroundResultInfluential
Cited by
TeslaTouch: electrovibration for touch surfaces
Bau, O., Poupyrev, I., Israr, A., & Harrison, C. (2010) · Proceedings of the 23nd annual ACM symposium on User interface software and technology · doi:10.1145/1866029.1866074 · Cited by 664
Self-citationPerceptual space and adjective rating of sinusoidal vibrations perceived via mobile device
Hwang, I., & Choi, S. (2010) · 2010 IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444692 · Cited by 54
“We also carefully calibrated the rela tionship between input voltage amplitude and output vibration am plitude for each frequency, following the calibration procedure s in [ 11 ].”
Self-citationMechanical Vibration Influences the Perception of Electrovibration
Ryu, S., Pyo, D., Lim, S.-C., & Kwon, D.-S. (2018) · Scientific Reports · doi:10.1038/s41598-018-22865-x · Cited by 31
Metadata
- Authors
- Israr, A., Choi, S., & Tan, H.
- Venue
- 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2006-10
- Pages
- 472-477
- OpenAlex
- W2069735249
- Cited by
- 65
- References
- 2
- FWCI
- 6.86
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.