The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A Toolbox for Easily Calibrating Omnidirectional Cameras
Open accessAbstract
In this paper, we present a novel technique for calibrating central omnidirectional cameras. The proposed procedure is very fast and completely automatic, as the user is only asked to collect a few images of a checker board, and click on its corner points. In contrast with previous approaches, this technique does not use any specific model of the omnidirectional sensor. It only assumes that the imaging function can be described by a Taylor series expansion whose coefficients are estimated by solving a four-step least-squares linear minimization problem, followed by a non-linear refinement based on the maximum likelihood criterion. To validate the proposed technique, and evaluate its performance, we apply the calibration on both simulated and real data. Moreover, we show the calibration accuracy by projecting the color information of a calibrated camera on real 3D points extracted by a 3D sick laser range finder. Finally, we provide a Toolbox which implements the proposed calibration procedure
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Flexible Technique for Accurate Omnidirectional Camera Calibration and Structure from Motion
Scaramuzza, D., Martinelli, A., & Siegwart, R. (2006) · Fourth IEEE International Conference on Computer Vision Systems (ICVS'06) · doi:10.1109/icvs.2006.3 · Cited by 417
Self-citationA theory of catadioptric image formation
Baker, S., & Nayar, S. K. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710698 · Cited by 377
Ego-motion and omnidirectional cameras
Gluckman, J., & Nayar, S. K. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710838 · Cited by 210
Paracatadioptric camera calibration
Geyer, C., & Daniilidis, K. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.1000241 · Cited by 197
Geometric properties of central catadioptric line images and their application in calibration
Barreto, J. P., & Araujo, H. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.163 · Cited by 180
EKF-based 3D SLAM for structured environment reconstruction
Weingarten, J., & Siegwart, R. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545285 · Cited by 167
Self-citationAutocalibration & 3D reconstruction with non-central catadioptric cameras
Micusik, B., & Pajdla, T. (2004) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2004.1315014 · Cited by 96
Cited by
A Survey of Autonomous Driving: Common Practices and Emerging Technologies
Yurtsever, E., Lambert, J., Carballo, A., & Takeda, K. (2020) · IEEE Access · doi:10.1109/access.2020.2983149 · Cited by 1,889
“These are however difficult to intrinsically calibrate; the spherical images are highly distorted and the camera model used must account for mirror reflections or fisheye lens distortions, depending on the camera model producing the panoramic images [139], [140].”
1 year, 1000 km: The Oxford RobotCar dataset
Maddern, W., Pascoe, G., Linegar, C., & Newman, P. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916679498 · Cited by 1,632
Automatic camera and range sensor calibration using a single shot
Geiger, A., Moosmann, F., Car, O., & Schuster, B. (2012) · 2012 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2012.6224570 · Cited by 647
Computer Vision for Autonomous Vehicles: Problems, Datasets and State of the Art
Janai, J., Güney, F., Behl, A., & Geiger, A. (2020) · Foundations and Trends® in Computer Graphics and Vision · doi:10.1561/0600000079 · Cited by 643
A Deep Learning-based Radar and Camera Sensor Fusion Architecture for Object Detection
Nobis, F., Geisslinger, M., Weber, M., Betz, J., & Lienkamp, M. (2019) · 2019 Sensor Data Fusion: Trends, Solutions, Applications (SDF) · doi:10.1109/sdf.2019.8916629 · Cited by 335
M2DGR: A Multi-Sensor and Multi-Scenario SLAM Dataset for Ground Robots
Yin, J., Li, A., Li, T., Yu, W., & Zou, D. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3138527 · Cited by 299
Martinelli, A. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2160468 · Cited by 279
Self-citationReal-time monocular visual odometry for on-road vehicles with 1-point RANSAC
Scaramuzza, D., Fraundorfer, F., & Siegwart, R. (2009) · 2009 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2009.5152255 · Cited by 279
Self-citationMetasurface-driven full-space structured light for three-dimensional imaging
Kim, G., Kim, Y., Yun, J., Moon, S.-W., Kim, S., Kim, J., Park, J., Badloe, T., Kim, I., & Rho, J. (2022) · Nature Communications · doi:10.1038/s41467-022-32117-2 · Cited by 253
Omnidirectional 3D reconstruction in augmented Manhattan worlds
Schonbein, M., & Geiger, A. (2014) · 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2014.6942637 · Cited by 63
An Enhanced Unified Camera Model
Khomutenko, B., Garcia, G., & Martinet, P. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2015.2502921 · Cited by 58
“Equivalence between the unified model and the captured ray-based model as well as the pinhole model was shown in [4].”
Method
Metadata
- Authors
- Scaramuzza, D., Martinelli, A., & Siegwart, R.
- Venue
- 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2006-10
- Pages
- 5695-5701
- OpenAlex
- W3145547920
- Cited by
- 510
- References
- 7
- FWCI
- 4.24
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.