The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design and functional evaluation of an epidermal strain sensing system for hand tracking
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Prior wearable finger-sensing work shows that meander-pattern strain gauges can separately capture MCP and PIP joint angles using multiple sensing zones on a single, thin, skin-conforming substrate [44].”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kuwazuru, O., Saothong, J., & Yoshikawa, N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.001 · Cited by 90
Research works printed but not linked: 19
- michaud, 0, Soft Flexion Sensors Integrating Stretchable Metal Conductors on a Silicone Substrate for Smart Glove Applications, 2015 IEEE International Conference on Micro Electro Mechanical Systems, 760
- 10.1109/ICRA.2015.7139544 · DOI
- 10.1002/adfm.201200498 · DOI · Paper page
- 10.1109/IROS.2011.6094701 · DOI · Paper page
- 10.1109/IROS.2014.6943125 · DOI
- 10.1002/adma.201506234 · DOI · Paper page
- 10.4067/S0717-95022010000300015 · DOI · Paper page
- 10.1055/s-0031-1271804 · doi:10.1055/s-0031-1271804
- 10.1007/978-0-387-30877-7_12 · doi:10.1007/978-0-387-30877-7_12
- 10.1109/BIBMW.2010.5703907 · DOI
- park, 2009, Development of wireless data glove for unrestricted upper-extremity rehabilitation system, 2009 ICCAS-SICE, 790
- 10.1109/IROS.2015.7353690 · DOI
- 10.1002/adfm.201504755 · DOI · Paper page
- 10.1016/j.robot.2014.08.014 · DOI · Paper page
- 10.1017/S0263574714002288 · DOI
- 10.1016/j.medengphy.2006.11.010 · DOI · Paper page
- 10.1016/j.bspc.2007.09.001 · DOI · Paper page
- 10.1002/adfm.201404365 · DOI · Paper page
- 10.1109/TBME.2007.908087 · DOI
Cited by
A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System
Oppenheim, T., Schlegel, H., Xie, P. Y., Khokhar, Z., & Khanna, P. (2026) · Sensors · doi:10.3390/s26154795
Metadata
- Authors
- Michaud, H. O., Dejace, L., de Mulatier, S., & Lacour, S. P.
- Venue
- 2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)
- Publisher
- IEEE
- Published
- 2016-10
- Pages
- 3186-3191
- Cited by
- 13
- References
- 1
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and functional evaluation of an epidermal strain sensing system for hand tracking. https://app.cochat.ai/papers/10.1109/iros.2016.7759492
- The paper
- Michaud, H. O., Dejace, L., de Mulatier, S., & Lacour, S. P. (2016). Design and functional evaluation of an epidermal strain sensing system for hand tracking. 2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). https://doi.org/10.1109/iros.2016.7759492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.