Magnetic resonance image synthesis through patch regression
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging (MRI) is widely used for analyzing human brain structure and function. MRI is extremely versatile and can produce different tissue contrasts as required by the study design. For reasons such as patient comfort, cost, and improving technology, certain tissue contrasts for a cohort analysis may not have been acquired during the imaging session. This missing pulse sequence hampers consistent neuroanatomy research. One possible solution is to synthesize the missing sequence. This paper proposes a data-driven approach to image synthesis, which provides equal, if not superior synthesis compared to the state-of-the-art, in addition to being an order of magnitude faster. The synthesis transformation is done on image patches by a trained bagged ensemble of regression trees. Validation was done by synthesizing T2-weighted contrasts from T1-weighted scans, for phantoms and real data. We also synthesized 3 Tesla T1-weighted magnetization prepared rapid gradient echo (MPRAGE) images from 1.5 Tesla MPRAGEs to demonstrate the generality of this approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marcus, D. S., Wang, T. H., Parker, J., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.9.1498 · Cited by 2,163
Cited by
Image Synthesis in Multi-Contrast MRI With Conditional Generative Adversarial Networks
Dar, S. U., Yurt, M., Karacan, L., Erdem, A., Erdem, E., & Cukur, T. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901750 · Cited by 608
Hi-Net: Hybrid-Fusion Network for Multi-Modal MR Image Synthesis
Zhou, T., Fu, H., Chen, G., Shen, J., & Shao, L. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2975344 · Cited by 399
Multimodal MR Synthesis via Modality-Invariant Latent Representation
Chartsias, A., Joyce, T., Giuffrida, M. V., & Tsaftaris, S. A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2764326 · Cited by 341
MRBrainS Challenge: Online Evaluation Framework for Brain Image Segmentation in 3T MRI Scans
Mendrik, A. M., Vincken, K. L., Kuijf, H. J., Breeuwer, M., Bouvy, W. H., de Bresser, J., Alansary, A., de Bruijne, M., Carass, A., El-Baz, A., et al. (2015) · Computational Intelligence and Neuroscience · doi:10.1155/2015/813696 · Cited by 261
Self-citationMissing MRI Pulse Sequence Synthesis Using Multi-Modal Generative Adversarial Network
Sharma, A., & Hamarneh, G. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2945521 · Cited by 254
Metadata
- Authors
- Jog, A., Roy, S., Carass, A., & Prince, J. L.
- Venue
- 2013 IEEE 10th International Symposium on Biomedical Imaging
- Publisher
- IEEE
- Published
- 2013-04
- Volume
- 2013
- Pages
- 350-353
- OpenAlex
- W1979775925
- Cited by
- 80
- References
- 1
- FWCI
- 19.18
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.