Automated assessment of endometrium from transvaginal ultrasound using Deep Learned Snake
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Endometrium assessment via thickness measurement is commonly performed in routine gynecological ultrasound examination for assessing the reproductive health of patients undergoing fertility related treatments and endometrium cancer screening in women with post-menopausal bleeding. This paper introduces a fully automated technique for endometrium thickness measurement from three-dimensional transvaginal ultrasound (TVUS) images. The algorithm combines the robustness of deep neural networks with the more interpretable level set method for segmentation. We propose a hybrid variational curve propagation model which embeds a deep-learned endometrium probability map in the segmentation energy functional. This solution provides approximately 30% performance improvement over a contemporary supervised learning method on a database of 59 TVUS images and the thickness measurement is found to be within ±2mm of the manual measurement in 87% of the cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Cited by
Deep Learning in Medical Ultrasound Analysis: A Review
Liu, S., Wang, Y., Yang, X., Lei, B., Liu, L., Li, S. X., Ni, D., & Wang, T. (2019) · Engineering · doi:10.1016/j.eng.2018.11.020 · Cited by 798
Introduction to artificial intelligence in ultrasound imaging in obstetrics and gynecology
Drukker, L., Noble, J. A., & Papageorghiou, A. T. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22122 · Cited by 240
“In obstetric and gynecological ultrasound, promising workload-changing advancements include automatic detection of standard planes and quality assurance in fetal ultrasound 43–45 , detection of endometrial thickness in gynecology 46 and automatic classification of ovarian cysts (Table 1).”
BackgroundAutomatic Measurement of Endometrial Thickness From Transvaginal Ultrasound Images
Liu, Y., Zhou, Q., Peng, B., Jiang, J., Fang, L., Weng, W., Wang, W., Wang, S., & Zhu, X. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.853845 · Cited by 23
Wang, X., Bao, N., Xin, X., Tan, J., Li, H., Zhou, S., & Liu, H. (2022) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-1155 · Cited by 20
Metadata
- Authors
- Singhal, N., Mukherjee, S., & Perrey, C.
- Venue
- 2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017)
- Publisher
- IEEE
- Published
- 2017-04
- Pages
- 283-286
- OpenAlex
- W2644685669
- Cited by
- 21
- References
- 1
- FWCI
- 0.57
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated assessment of endometrium from transvaginal ultrasound using Deep Learned Snake. https://app.cochat.ai/papers/10.1109/isbi.2017.7950520
- The paper
- Singhal, N., Mukherjee, S., & Perrey, C. (2017). Automated assessment of endometrium from transvaginal ultrasound using Deep Learned Snake. 2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017). https://doi.org/10.1109/isbi.2017.7950520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.