The DOI matches its Crossref record.
Cascaded H-bridge multilevel converter multistring topology for large scale photovoltaic systems
Open accessAbstract
Large scale grid connected photovoltaic (PV) energy conversion systems have reached the megawatt level. This imposes new challenges on existing grid interface converter topologies and opens new opportunities to be explored. In this paper a new medium voltage multilevel-multistring configuration is introduced based on a three-phase cascaded H-bridge (CHB) converter and multiple string dc-dc converters. The proposed configuration enables a large increase of the total capacity of the PV system, while improving power quality and efficiency. The converter structure is very flexible and modular since it decouples the grid converter from the PV string converter, which allows to accomplish independent control goals. The main challenge of the proposed configuration is to handle the inherent power imbalances that occur not only between the different cells of one phase of the converter but also between the three phases. The control strategy to deal with these imbalances is also introduced in this paper. Simulation results of a 7-level CHB for a multistring PV system are presented to validate the proposed topology and control method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Kouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197
Self-citationGrid-Connected Photovoltaic Generation Plants: Components and Operation
Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2264540 · Cited by 449
Self-citationAnalysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402
Hossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Metadata
- Authors
- Rivera, S., Kouro, S., Wu, B., Leon, J. I., Rodriguez, J., & Franquelo, L. G.
- Venue
- 2011 IEEE International Symposium on Industrial Electronics
- Publisher
- IEEE
- Published
- 2011-06
- Pages
- 1837-1844
- OpenAlex
- W2159388303
- Cited by
- 233
- References
- 0
- FWCI
- 23.49
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cascaded H-bridge multilevel converter multistring topology for large scale photovoltaic systems. https://app.cochat.ai/papers/10.1109/isie.2011.5984437
- The paper
- Rivera, S., Kouro, S., Wu, B., Leon, J. I., Rodriguez, J., & Franquelo, L. G. (2011). Cascaded H-bridge multilevel converter multistring topology for large scale photovoltaic systems. 2011 IEEE International Symposium on Industrial Electronics. https://doi.org/10.1109/isie.2011.5984437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.