IGBT behavior during desat detection and short circuit fault protection
The DOI matches its Crossref record.
Abstract
A common fault condition in motor drive applications involves an IGBT turning on into a short-circuit. If the only impedance is the cable inductance to a shorted motor winding, the current through the device ramps up very rapidly until it saturates, forcing the IGBT voltage to rise to the DC clamp. After fault detection, depending on the point at which the fast turn-off pulse is applied, very different levels of hole current can flow under the n/sup +/ source region, making this an important factor in the successful containment of the fault current. We present experimental observations showing that IGBT failure under short-circuit conditions is dependent on where the turn-off pulse is applied. The physics of this behavior is explained using numerical mixed-mode simulations. A practical two step gate waveform is studied for avoidance of device failure under short-circuit conditions, and is experimentally demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
“8) Protection by Two-Step Gate Pulse [ 32 ]: In hard switched fault, the device current ramps up very rapidly until it saturates, forcing the IGBT voltage to rise to the dc clamp.”
MethodWelchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
“A standard Vce desaturation-based fault detection is used for the IGBT short-circuit fault detection [17].”
MethodInvestigations of 600-V GaN HEMT and GaN Diode for Power Converter Applications
Mitova, R., Ghosh, R., Mhaskar, U., Klikic, D., Wang, M.-X., & Dentella, A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2286639 · Cited by 221
“A converter is subjected to different types of short-circuit failure [38], where the devices carry large current for a short duration before the gate driver detects it and stops the gating pulses [35].”
BackgroundResultInfluential
Metadata
- Authors
- Bhalla, A., Shekhawat, S., Gladish, J., Yedinak, J., & Dolny, G.
- Venue
- Proceedings of the 10th International Symposium on Power Semiconductor Devices and ICs. ISPSD'98 (IEEE Cat. No.98CH36212)
- Publisher
- Inst. Electr. Eng. Japan
- Published
- 2002-11-27
- Pages
- 245-248
- ISSN
- 1063-6854 (ISSN-L)
- OpenAlex
- W2170884280
- Cited by
- 36
- References
- 0
- FWCI
- 0.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.