The DOI matches its Crossref record.
Fault Tolerant Three-Phase AC Motor Drive Topologies: A Comparison of Features, Cost, and Limitations
Abstract
This paper compares the many fault tolerant three-phase ac motor drive topologies that have been proposed to provide output capacity for the inverter faults of switch short or open-circuits, phase-leg short-circuits, and single-phase open-circuits. Also included is a review of the respective control methods for fault tolerant inverters including two-phase and unipolar control methods. The output voltage and current space in terms of dq components is identified for each topology and fault. These quantities are then used to normalize the power capacity of each system during a fault to a standard inverter during normal operation. A silicon overrating cost factor is adopted as a metric to compare the relative switching device costs of the topologies compared to a standard three-phase inverter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 27
- 10.1109/28.297920 · DOI · Paper page
- 10.1109/PESC.1996.548786 · DOI
- 10.1109/PSEC.2002.1022381 · DOI
- 10.1109/28.511646 · DOI · Paper page
- 10.1109/28.315238 · DOI · Paper page
- 10.1109/TIA.1980.4503793 · DOI
- 10.1109/28.739017 · DOI · Paper page
- 10.1109/TPEL.2003.809351 · DOI · Paper page
- 10.1109/28.370271 · DOI
- 10.1109/ISPSD.1998.702679 · DOI
- 10.1109/IEMDC.2001.939291 · DOI
- 10.1109/28.54251 · DOI
- 10.1109/28.245714 · DOI · Paper page
- 10.1109/IAS.1993.299023 · DOI
- 10.1109/41.873223 · DOI · Paper page
- 10.1109/IAS.1993.298887 · DOI
- 10.1109/IAS.2000.882152 · DOI
- 10.1109/PESC.2001.954281 · DOI
- 10.1109/IEMDC.1997.604282 · DOI
- 10.1109/28.924770 · DOI
- Ribero, A strategy for improving reliability of motor drive systems using a four-leg three-phase converter, 1, 385
- 10.1109/TIA.1984.4504413 · DOI · Paper page
- 10.1093/oso/9780198564393.001.0001 · DOI · Paper page
- Mohan, 1995, Power Electronics: Converters, Applications and Design
- Stemmler, Configurations of high-power voltage source inverter drives, 7
- 10.1109/60.790893 · DOI
- 10.1109/28.968186 · DOI
Cited by
Transitioning to Physics-of-Failure as a Reliability Driver in Power Electronics
Wang, H., Liserre, M., Blaabjerg, F., de Place Rimmen, P., Jacobsen, J. B., Kvisgaard, T., & Landkildehus, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2290282 · Cited by 693
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“A detailed overview of fault-tolerant inverter topologies is presented in [307], [308].”
BackgroundFault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284
Metadata
- Authors
- Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2004-07
- Volume
- 19
- Issue
- 4
- Pages
- 1108-1116
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2131789431
- Cited by
- 724
- References
- 0
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault Tolerant Three-Phase AC Motor Drive Topologies: A Comparison of Features, Cost, and Limitations. https://app.cochat.ai/papers/10.1109/tpel.2004.830074
- The paper
- Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004). Fault Tolerant Three-Phase AC Motor Drive Topologies: A Comparison of Features, Cost, and Limitations. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2004.830074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.