A cubic-millimeter energy-autonomous wireless intraocular pressure monitor
Abstract
Glaucoma is the leading cause of blindness, affecting 67 million people worldwide. The disease damages the optic nerve due to elevated intraocular pressure (IOP) and can cause complete vision loss if untreated. IOP is commonly assessed using a single tonometric measurement, which provides a limited view since IOP fluctuates with circadian rhythms and physical activity. Continuous measurement can be achieved with an implanted monitor to improve treatment regiments, assess patient compliance to medication schedules, and prevent unnecessary vision loss. The most suitable implantation location is the anterior chamber of the eye, which is surgically accessible and out of the field of vision. The desired IOP monitor (IOPM) volume is limited to 1.5mm3(0.5x1.5x2mm3) by the size of a self-healing incision, curvature of the cornea, and dilation of the pupil.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chen, L. Y., Tee, B. C. K., Chortos, A. L., Schwartz, G., Tse, V., J. Lipomi, D., Wong, H. S. P., McConnell, M. V., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms6028 · Cited by 541
A Portable 2-Transistor Picowatt Temperature-Compensated Voltage Reference Operating at 0.5 V
Seok, M., Kim, G., Blaauw, D., & Sylvester, D. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2206683 · Cited by 459
Self-citationRF power harvesting: a review on designing methodologies and applications
Tran, L.-G., Cha, H.-K., & Park, W.-T. (2017) · Micro and Nano Systems Letters · doi:10.1186/s40486-017-0051-0 · Cited by 293
Energy extraction from the biologic battery in the inner ear
Mercier, P. P., Lysaght, A. C., Bandyopadhyay, S., Chandrakasan, A. P., & Stankovic, K. M. (2012) · Nature Biotechnology · doi:10.1038/nbt.2394 · Cited by 217
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Metadata
- Authors
- Chen, G., Ghaed, H., Haque, R.-U., Wieckowski, M., Kim, Y., Kim, G., Fick, D., Kim, D., Seok, M., Wise, K., Blaauw, D., & Sylvester, D.
- Venue
- 2011 IEEE International Solid-State Circuits Conference
- Publisher
- IEEE
- Published
- 2011-02
- Pages
- 310-312
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W2010689540
- Cited by
- 208
- References
- 0
- FWCI
- 68.49
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A cubic-millimeter energy-autonomous wireless intraocular pressure monitor. https://app.cochat.ai/papers/10.1109/isscc.2011.5746332
- The paper
- Chen, G., Ghaed, H., Haque, R.-U., Wieckowski, M., Kim, Y., Kim, G., Fick, D., Kim, D., Seok, M., Wise, K., Blaauw, D., & Sylvester, D. (2011). A cubic-millimeter energy-autonomous wireless intraocular pressure monitor. 2011 IEEE International Solid-State Circuits Conference. https://doi.org/10.1109/isscc.2011.5746332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.