CoChat

17.5 A 0.8mm3 Ultrasonic Implantable Wireless Neural Recording System With Linear AM Backscattering

Ghanbari, Mohammad Meraj, Piech, David K., Shen, Konlin, Alamouti, Sina Faraji, Yalcin, Cem, Johnson, Benjamin C., Carmena, Jose M., Maharbiz, Michel M., Muller, Rikky · 2019 · 2019 IEEE International Solid- State Circuits Conference - (ISSCC)
Cited by 42

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Miniaturization of implantable neural recording systems to micron-scale volumes will enable minimally invasive implantation and alleviate cortical scarring, gliosis, and resulting signal degradation. Ultrasound (US) power transmission has been demonstrated to have high efficiency and low tissue attenuation for mm-scale implants at depth in tissue [1, 2, 3], but has not been demonstrated with precision recording circuitry. We present an US implantable wireless neural recording system scaled to 0.8mm3, verified to safely operate at 5cm depth with state of the art neural recording performance an average circuit power dissipation of 13μW, and 28.8μW including power conversion efficiency. Sub-mm scale is achieved through single-link power and communication on a single piezocrystal (Lead Zirconate Titanate, PZT) utilizing linear analog backscattering, small die area, and eliminating all other off-chip components.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/isscc.2019.8662295

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 42

Metadata

Authors
Ghanbari, M. M., Piech, D. K., Shen, K., Alamouti, S. F., Yalcin, C., Johnson, B. C., Carmena, J. M., Maharbiz, M. M., & Muller, R.
Venue
2019 IEEE International Solid- State Circuits Conference - (ISSCC)
Publisher
IEEE
Published
2019-02
Pages
284-286
ISSN
0193-6530 (ISSN-L)
OpenAlex
W2922423338
Cited by
42
References
1
FWCI
24.30
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 17.5 A 0.8mm3 Ultrasonic Implantable Wireless Neural Recording System With Linear AM Backscattering. https://app.cochat.ai/papers/10.1109/isscc.2019.8662295
The paper
Ghanbari, M. M., Piech, D. K., Shen, K., Alamouti, S. F., Yalcin, C., Johnson, B. C., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2019). 17.5 A 0.8mm3 Ultrasonic Implantable Wireless Neural Recording System With Linear AM Backscattering. 2019 IEEE International Solid- State Circuits Conference - (ISSCC). https://doi.org/10.1109/isscc.2019.8662295

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.