Vibration monitoring of PM synchronous machine with partial demagnetization and inter-turn short circuit faults
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Monitoring permanent magnet synchronous machine (PMSM) faults including partial demagnetization, inter-turn short circuit is necessary for safety and reliable operation. This paper studies vibration acceleration to detect faults using both mode shape and vibration frequency information. For this purpose, Finite element analysis is used to calculate the radial force distribution applied on the stator teeth and mode shape of the PMSM. 2-dimensional Fast Fourier Transformation (FFT) is employed to extract the significant harmonic orders, which dominate the vibration. Simulation and experimental results indicate that featured low mode order and corresponding frequency component would appear under fault conditions. Simulation and experimental results are used to analyze the effectiveness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Self-citationDa, Y., Shi, X., & Krishnamurthy, M. (2011) · 2011 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2011.6043248 · Cited by 96 · cited 1×
“INTRODUCTION Vibration monitoring [1-6] as a non-intrusive approach, is extensively used for electric fault diagnosis of PMSM.”
BackgroundSelf-citation
Research works printed but not linked: 8
- 10.1049/ip-epa:20050253 · DOI
- 10.1109/TMAG.2010.2044582 · DOI
- 10.1109/TMAG.2005.847628 · DOI
- 10.1049/iet-epa.2010.0159 · DOI · Paper page
- 10.1109/IEMDC.2013.6556267 · doi:10.1109/iemdc.2013.6556267
- 10.1049/ip-b.1986.0022 · DOI · Paper page
- yang, 2012, A Flat linear generator with axial magnetized permanent magnets for backpack energy harvesting, IEEE Applied Power Electronics Conference (APEC), 380
- 10.1109/ECCE.2012.6342797 · DOI
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[99] Vibration FFT PDF, NINV, ON, NAOF SC, VM, MS”
BackgroundMethodFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Improved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
Metadata
- Authors
- Yang, Z., Shi, X., & Krishnamurthy, M.
- Venue
- 2014 IEEE Transportation Electrification Conference and Expo (ITEC)
- Publisher
- IEEE
- Published
- 2014-06
- Pages
- 1-6
- OpenAlex
- W2055416435
- Cited by
- 72
- References
- 2
- FWCI
- 6.94
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibration monitoring of PM synchronous machine with partial demagnetization and inter-turn short circuit faults. https://app.cochat.ai/papers/10.1109/itec.2014.6861774
- The paper
- Yang, Z., Shi, X., & Krishnamurthy, M. (2014). Vibration monitoring of PM synchronous machine with partial demagnetization and inter-turn short circuit faults. 2014 IEEE Transportation Electrification Conference and Expo (ITEC). https://doi.org/10.1109/itec.2014.6861774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.