Differentiating essential tremor and Parkinson’s disease using a wearable sensor—a pilot study
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Essential tremor is the most common form of tremors presenting an outpatient neurology practice and yet it may be often difficult to differentiate with tremors in Parkinson's disease - one of the commonest neurodegenerative disease. Since using appropriate medication is fundamental for efficacy and avoiding serious side effects, precise diagnoses are recommended. Single photon emission computerized tomography (SPECT) of the dopamine transporter (DAT) is a sensitive and specific imaging tool, but expensive and not advisable as screening means. Wearable devices are developing such effective and affordable supports for clinicians. This work aims to be a pilot study of future tremor classification. A low-cost miniaturized wearable device was exploited to collect movements of subject's hand during resting, postural and kinetic tasks. Data were analyzed to extract parameters describing tremors frequency distribution. Results confirm that PD and ET are well separated in the frequency domain, laying the basis for accurate classification.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Already, some studies have shown that wearable sensors and smartphones can be utilized to distinguish individuals with ET from healthy individuals and people with PD (85–91).”
From Could Wearable and Mobile Technology Improve the Management of Essential Tremor? (2018) · cites this paper as [87]
Citations
Cites
Benamer, H. T. S., Patterson, J., Grosset, D. G., Booij, J., de Bruin, K., van Royen, E., Speelman, J. D., Horstink, M. H. I. M., Sips, H. J. W. A., Dierckx, R. A., et al. (2000) · Movement Disorders · doi:10.1002/1531-8257(200005)15:3<503::aid-mds1013>3.0.co;2-v · Cited by 707
The current and projected economic burden of Parkinson's disease in the United States
Kowal, S. L., Dall, T. M., Chakrabarti, R., Storm, M. V., & Jain, A. (2013) · Movement Disorders · doi:10.1002/mds.25292 · Cited by 667 · cited 1×
“It is therefore appropriate to investigate efficient and inexpensive methods for their management [11].”
MethodAgeing, neurodegeneration and Parkinson's disease
Hindle, J. V. (2010) · Age and Ageing · doi:10.1093/ageing/afp223 · Cited by 430
The role of DAT-SPECT in movement disorders
Kagi, G., Bhatia, K. P., & Tolosa, E. (2010) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2008.157370 · Cited by 311
Diagnosis and Treatment of Common Forms of Tremor
Puschmann, A., & Wszolek, Z. (2011) · Seminars in Neurology · doi:10.1055/s-0031-1271312 · Cited by 138
Louis, E. D., & Ottman, R. (2014) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.198 · Cited by 123
Louis, E. D., & Ottman, R. (2014) · PubMed · doi:10.7916/d8tt4p4b · Cited by 109
Environmental Epidemiology of Essential Tremor
Louis, E. D. (2008) · Neuroepidemiology · doi:10.1159/000151523 · Cited by 78
Surangsrirat, D., Thanawattano, C., Pongthornseri, R., Dumnin, S., Anan, C., & Bhidayasiri, R. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592190 · Cited by 42
A Novel Body Sensor Network for Parkinson's Disease Patients Rehabilitation Assessment
Caldara, M., Comotti, D., Galizzi, M., Locatelli, P., Re, V., Alimonti, D., Poloni, M., & Rizzetti, M. C. (2014) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2014.28 · Cited by 34
Self-citation
Research works printed but not linked: 3
- 2012, Ageing and Life Course WHO
- foundation, 0, Statistics on Parkinson's - Parkinson's disease foundation (PDF)
- census, 2011, Projections of the population by selected age groups and sex for the United States 2010 to 2050 national population projections (released 2008)
Cited by
Talitckii, A., Kovalenko, E., Anikina, A., Zimniakova, O., Semenov, M., Витальевна, Б. Е., Shcherbak, A., Dylov, D. V., & Somov, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3027564 · Cited by 57
Kuosmanen, E., Wolling, F., Vega, J., Kan, V., Nishiyama, Y., Harper, S., Laerhoven, K. V., Hosio, S. J., & Ferreira, D. (2020) · JMIR mhealth and uhealth · doi:10.2196/21543 · Cited by 45
Duque, J. D. L., Egea, A. J. S., Reeb, T., Rojas, H. A. G., & González‐Vargas, A. M. (2020) · IEEE Access · doi:10.1109/access.2020.2993647 · Cited by 44
Classification of Essential Tremor and Parkinson’s Tremor Based on a Low-Power Wearable Device
Locatelli, P., Alimonti, D., Traversi, G., & Re, V. (2020) · Electronics · doi:10.3390/electronics9101695 · Cited by 41
Self-citationTalitckii, A., Anikina, A., Kovalenko, E., Shcherbak, A., Mayora, O., Zimniakova, O., Витальевна, Б. Е., Semenov, M., Dylov, D. V., & Somov, A. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3097857 · Cited by 35
Upper limb intention tremor assessment: opportunities and challenges in wearable technology
Paredes-Acuña, N., Utpadel-Fischler, D., Ding, K., Thakor, N. V., & Cheng, G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01302-9 · Cited by 27
Duque, J. D. L., González‐Vargas, A. M., Egea, A. J. S., & Rojas, H. A. G. (2019) · Communications in computer and information science · doi:10.1007/978-3-030-31019-6_32 · Cited by 24
Could Wearable and Mobile Technology Improve the Management of Essential Tremor?
Daneault, J.-F. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00257 · Cited by 21
The Best Digital Biomarkers Papers of 2017
Snyder, C. W., Dorsey, E. R., & Atreja, A. (2018) · Digital Biomarkers · doi:10.1159/000489224 · Cited by 19
Development of a New Wearable Device for the Characterization of Hand Tremor
Vescio, B., Maria, M. D., Crasà, M., Nisticò, R., Calomino, C., Aracri, F., Quattrone, A., & Quattrone, A. (2023) · Bioengineering · doi:10.3390/bioengineering10091025 · Cited by 19
Intelligent devices for assessing essential tremor: a comprehensive review
Peng, Y., Ma, C., Li, M., Liu, Y., Yu, J., Pan, L., & Zhang, Z. (2024) · Journal of Neurology · doi:10.1007/s00415-024-12354-9 · Cited by 17
A Wearable Prototype for Neurological Symptoms Recognition
Sciarrone, A., Bisio, I., Garibotto, C., Lavagetto, F., Staude, G., & Knopp, A. (2020) · International Conference on Communications · doi:10.1109/icc40277.2020.9149017 · Cited by 7
Wearable Sensors and Machine Learning Fusion for Parkinson's Disease Assessment
Hammoud, M., Shcherbak, A., Getahun, M. N., Istrakova, O., Shindryaeva, N., Zimniakova, O., Витальевна, Б. Е., Semenov, M., Baldycheva, A. V., & Somov, A. (2024) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc60896.2024.10561139 · Cited by 6
NeuroGlasses: A Wearable Prototype for Early Detection of Neurological Symptoms
Sciarrone, A., Bisio, I., Garibotto, C., Lavagetto, F., Hamedani, M., Prada, V., Stara, S., Schenone, A. E., Boero, F., & Gambari, G. (2020) · International Conference on Smart and Sustainable Technologies (SpliTech) · doi:10.23919/splitech49282.2020.9243713 · Cited by 5
Advances in wearable sensor-based automatic tremor classification
Locatelli, P., & Alimonti, D. (2018) · International Conference on Modern Circuits and Systems Technologies · doi:10.1109/mocast.2018.8376602 · Cited by 4
Self-citationEarly Detection of External Neurological Symptoms through a Wearable Smart-Glasses Prototype
Sciarrone, A., Bisio, I., Garibotto, C., Lavagetto, F., Hamedani, M., Prada, V., Schenone, A. E., Boero, F., Gambari, G., Cereia, M., et al. (2021) · Journal of Communications Software and Systems · doi:10.24138/jcomss-2021-0071 · Cited by 4
RT-ring: a small wearable device for tremulous Parkinson’s disease diagnosis in primary care
Buonocore, J., Vescio, B., Maria, M. D., Crasà, M., Nisticò, R., Arcuri, P. P., Cascini, G. L., Latorre, A., Quattrone, A., & Quattrone, A. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1534205 · Cited by 3
Locatelli, P. (2021) · Aisberg (University of Bergamo) · doi:10.6092/978-88-97413-37-0 · Cited by 1
Self-citationWinter: A Novel Low Power Modular Platform for Wearable and IoT Applications
Locatelli, P., Hussain, A., Pedrana, A., Pezzoli, M., Traversi, G., & Re, V. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-3-030-66729-0_8 · Cited by 1
Self-citationMachine-learning to promote better practices of low-cost wearable devices in tremor diseases
Duque, J. D. L. (2023) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-404064
Hammoud, M., & Somov, A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3701543
An Intelligent Machine Learning Framework for Early Parkinsonian Symptom Identification
Sankar, S. R., Diya sawant, M., Harini, M., & Abinaya, R. (2026) · International Journal of Engineering & Extended Technologies Research · doi:10.15662/ijeetr.2026.0802091
Desarrollo de una app para el diagnóstico diferencial de pacientes con Parkinson y temblor esencial
Sánchez Egea, A. J. (2019) · RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Locatelli, P. (2019) · Aisberg (University of Bergamo) · doi:10.6092/tdunibg_128627
Self-citationWearable Devices in the Diagnosis and Treatment of Essential Tremor
Hyvärinen, H. (2026) · UEF eRepo (University of Eastern Finland) · doi:10.13140/rg.2.2.24253.12007
Metadata
- Authors
- Locatelli, P., & Alimonti, D.
- Affiliations
- University of Bergamo (IT)
- Ospedale Papa Giovanni XXIII (IT)
- Venue
- 2017 7th IEEE International Workshop on Advances in Sensors and Interfaces (IWASI)
- Publisher
- IEEE
- Published
- 2017-06
- Pages
- 213-218
- OpenAlex
- W2734856619
- Cited by
- 19
- References
- 15
- Citations by year
- 2026: 1 · 2024: 3 · 2023: 2 · 2021: 3 · 2020: 6 · 2019: 1 · 2018: 3
- FWCI
- 19.40
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Workshop on Advances in Sensors and Interfaces (IWASI) (publishedVersion)
- Aisberg (University of Bergamo) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- essential tremor, Parkinson's disease, tremor classification, wearable sensors, hand movement analysis, frequency domain analysis, low-cost wearable device, postural tremor, kinetic tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.