A Level-Crossing Based QRS-Detection Algorithm for Wearable ECG Sensors
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In this paper, an asynchronous analog-to-information conversion system is introduced for measuring the RR intervals of the electrocardiogram (ECG) signals. The system contains a modified level-crossing analog-to-digital converter and a novel algorithm for detecting the R-peaks from the level-crossing sampled data in a compressed volume of data. Simulated with MIT-BIH Arrhythmia Database, the proposed system delivers an average detection accuracy of 98.3%, a sensitivity of 98.89%, and a positive prediction of 99.4%. Synthesized in 0.13 μm CMOS technology with a 1.2 V supply voltage, the overall system consumes 622 nW with core area of 0.136 mm (2), which make it suitable for wearable wireless ECG sensors in body-sensor networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“Also the proposed system significantly improves detection accuracy compared to the previous works that use LC-ADC for QRS detection.”
ResultThe impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812 · cited 1×
“In this paper, a novel algorithm for extracting the RR intervals from the output data of the level-crossing-based ADC (LC-ADC) is proposed.”
MethodThe principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242 · cited 1×
“The basic techniques are based on the amplitude, i.e., first derivative or first and second derivatives of the signal [17], [18].”
BackgroundAnalysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413 · cited 1×
“The RR interval, which is the time interval between two consecutive R peaks, can be used to detect irregularities in the heart normal operation, called arrhythmia.”
MethodCompressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2193668 · Cited by 311 · cited 1×
“Under the scheme, the sampling rate is directly proportional to the activity of the input signal and no power is wasted for sampling, converting, and processing the useless data in the inactive parts of the signal.”
BackgroundA new class of asynchronous A/D converters based on time quantization
Allier, E., Sicard, G., Fesquet, L., & Renaudin, M. (2003) · IEEE International Symposium on Asynchronous Circuits and Systems (ASYNC) · doi:10.1109/async.2003.1199179 · Cited by 239 · cited 4×
“In order to transport and store these data by using a common synchronous system, the time intervals between the samples (Dti) can be quantized and represented with a limited number of bits [3].”
BackgroundInfluentialZhang, F., & Lian, Y. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2020093 · Cited by 231 · cited 2×
“Also the proposed system significantly improves detection accuracy compared to the previous works that use LC-ADC for QRS detection.”
BackgroundResultSelf-citationTrakimas, M., & Sonkusale, S. R. (2010) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2010.2092132 · Cited by 165 · cited 3×
“Color versions of one or more of the figures in this paper are available online at http://ieeexplore.ieee.org.”
BackgroundIeong, C.-I., Mak, P., Lam, C.-P., Dong, C., Vai, M. I., Mak, P. U., Pun, S. H., Wan, F., & Martins, R. P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2188798 · Cited by 137
Cited by
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
Serhani, M. A., T. El Kassabi, H., Ismail, H., & Nujum Navaz, A. (2020) · Sensors · doi:10.3390/s20061796 · Cited by 357
Metadata
- Authors
- Ravanshad, N., Rezaee-Dehsorkh, H., Lotfi, R., & Lian, Y.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-01
- Volume
- 18
- Issue
- 1
- Pages
- 183-192
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1971513336
- Cited by
- 172
- References
- 15
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.