A Machine Learning Approach to Improve Contactless Heart Rate Monitoring Using a Webcam
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Unobtrusive, contactless recordings of physiological signals are very important for many health and human-computer interaction applications. Most current systems require sensors which intrusively touch the user's skin. Recent advances in contact-free physiological signals open the door to many new types of applications. This technology promises to measure heart rate (HR) and respiration using video only. The effectiveness of this technology, its limitations, and ways of overcoming them deserves particular attention. In this paper, we evaluate this technique for measuring HR in a controlled situation, in a naturalistic computer interaction session, and in an exercise situation. For comparison, HR was measured simultaneously using an electrocardiography device during all sessions. The results replicated the published results in controlled situations, but show that they cannot yet be considered as a valid measure of HR in naturalistic human-computer interaction. We propose a machine learning approach to improve the accuracy of HR detection in naturalistic measurements. The results demonstrate that the root mean squared error is reduced from 43.76 to 3.64 beats/min using the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Data Mining: Practical Machine Learning Tools and Techniques
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-19715-5 · Cited by 25,437
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300 · cited 1×
“First, for each video, we detected the face area using OpenCV and an extended boosted cascade classifier (Haar classifier [14]).”
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The participant was cycling for 2 min in the “Easy” levels and for 3 min in “Normal” and “Hard” cycling levels.”
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · cited 1×
“Personal use is permitted, but republication/redistribution requires IEEE permission.”
BackgroundLearning openCV: computer vision with the openCV library
Bradski, G. R., & Kaehler, A. (2008) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,468
Instance-based learning algorithms
Aha, D. W., Kibler, D., & Albert, M. K. (1991) · Machine Learning · doi:10.1007/bf00153759 · Cited by 2,163 · cited 1×
“A false positive rate indicates the number of frames in which the algorithm detected more than one face divided by the total number of analyzed frames.”
BackgroundRemote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719 · cited 3×
“Recent advances in contactfree physiological signals open the door to many new types of applications.”
BackgroundNon-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Cited by
DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Remote patient monitoring: a comprehensive study
Malasinghe, L. P., Ramzan, N., & Dahal, K. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-017-0598-x · Cited by 534
“Heart rate measured using a web-camera has been proven accurate by conventional ECG readings (Monkaresi et al. 2014).”
MethodAutomated Detection of Engagement Using Video-Based Estimation of Facial Expressions and Heart Rate
Monkaresi, H., Bosch, N., Calvo, R. A., & D'Mello, S. K. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2515084 · Cited by 329
Self-citationPrivacy-Preserving Patient-Centric Clinical Decision Support System on Naïve Bayesian Classification
Liu, X., Lu, R., Ma, J., Chen, L., & Qin, B. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2407157 · Cited by 240
“Clinical decision support system (CDSS), with various data mining techniques being applied to assist physicians in diagnosing patient diseases with similar symptoms, has received a great attention recently [2]–[4].”
Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 227
“for HR estimation during both controlled lablike tasks and naturalistic situations [86].”
BackgroundMethodHeart rate estimation using facial video: A review
Hassan, M. A., Malik, A. S., Fofi, D., Saad, N., Karasfi, B., Ali, Y. S., & Meriaudeau, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.07.004 · Cited by 182
The aspects of running artificial intelligence in emergency care; a scoping review
(2023) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v11i1.1974 · Cited by 45
Beyond Mobile Apps: A Survey of Technologies for Mental Well-Being
Woodward, K., Kanjo, E., Brown, D. J., McGinnity, T. M., Inkster, B., Macintyre, D. J., & Tsanas, A. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2020.3015018 · Cited by 18
Metadata
- Authors
- Monkaresi, H., Calvo, R. A., & Yan, H.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-07
- Volume
- 18
- Issue
- 4
- Pages
- 1153-1160
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2082046021
- Cited by
- 179
- References
- 21
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.