The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
Abstract
Heart rate (HR) estimation and monitoring is of great importance to determine a person's physiological and mental status. Recently, it has been demonstrated that HR can be remotely retrieved from facial video-based photoplethysmographic signals captured using professional or consumer-level cameras. Many efforts have been made to improve the detection accuracy of this noncontact technique. This paper presents a timely, systematic survey on such video-based remote HR measurement approaches, with a focus on recent advancements that overcome dominating technical challenges arising from illumination variations and motion artifacts. Representative methods up to date are comparatively summarized with respect to their principles, pros, and cons under different conditions. Future prospects of this promising technique are discussed and potential research directions are described. We believe that such a remote HR measurement technique, taking advantages of unobtrusiveness while providing comfort and convenience, will be beneficial for many healthcare applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Improved motion robustness of remote-PPG by using the blood volume pulse signature
de Haan, G., & van Leest, A. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1913 · Cited by 491
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417 · cited 5×
“illumination variations [31], [32], [42]–[44].”
BackgroundMethodInfluential
Cited by
PhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformer
Yu, Z., Shen, Y., Shi, J., Zhao, H., Torr, P., & Zhao, G. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00415 · Cited by 300
Metadata
- Authors
- Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2019-10
- Volume
- 68
- Issue
- 10
- Pages
- 3600-3615
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2902449706
- Cited by
- 227
- References
- 4
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Video-Based Heart Rate Measurement: Recent Advances and Future Prospects. https://app.cochat.ai/papers/10.1109/tim.2018.2879706
- The paper
- Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019). Video-Based Heart Rate Measurement: Recent Advances and Future Prospects. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2018.2879706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.