Abstract

Several methods to estimate energy expenditure (EE) using body-worn sensors exist; however, quantifications of the differences in estimation error are missing. In this paper, we compare three prevalent EE estimation methods and five body locations to provide a basis for selecting among methods, sensors number, and positioning. We considered 1) counts-based estimation methods, 2) activity-specific estimation methods using METs lookup, and 3) activity-specific estimation methods using accelerometer features. The latter two estimation methods utilize subsequent activity classification and EE estimation steps. Furthermore, we analyzed accelerometer sensors number and on-body positioning to derive optimal EE estimation results during various daily activities. To evaluate our approach, we implemented a study with 15 participants that wore five accelerometer sensors while performing a wide range of sedentary, household, lifestyle, and gym activities at different intensities. Indirect calorimetry was used in parallel to obtain EE reference data. Results show that activity-specific estimation methods using accelerometer features can outperform counts-based methods by 88% and activity-specific methods using METs lookup for active clusters by 23%. No differences were found between activity-specific methods using METs lookup and using accelerometer features for sedentary clusters. For activity-specific estimation methods using accelerometer features, differences in EE estimation error between the best combinations of each number of sensors (1 to 5), analyzed with repeated measures ANOVA, were not significant. Thus, we conclude that choosing the best performing single sensor does not reduce EE estimation accuracy compared to a five sensors system and can reliably be used. However, EE estimation errors can increase up to 80% if a nonoptimal sensor location is chosen.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2014.2313039

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 117

Metadata

Authors
Altini, M., Penders, J., Vullers, R., & Amft, O.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2015-01
Volume
19
Issue
1
Pages
219-226
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W1990776473
Cited by
117
References
4
FWCI
12.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating Energy Expenditure Using Body-Worn Accelerometers: A Comparison of Methods, Sensors Number and Positioning. https://app.cochat.ai/papers/10.1109/jbhi.2014.2313039
The paper
Altini, M., Penders, J., Vullers, R., & Amft, O. (2015). Estimating Energy Expenditure Using Body-Worn Accelerometers: A Comparison of Methods, Sensors Number and Positioning. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2014.2313039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.