Bleeding Frame and Region Detection in the Wireless Capsule Endoscopy Video
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Wireless capsule endoscopy (WCE) enables noninvasive and painless direct visual inspection of a patient's whole digestive tract, but at the price of long time reviewing large amount of images by clinicians. Thus, an automatic computer-aided technique to reduce the burden of physicians is highly demanded. In this paper, we propose a novel color feature extraction method to discriminate the bleeding frames from the normal ones, with further localization of the bleeding regions. Our proposal is based on a twofold system. First, we make full use of the color information of WCE images and utilize K-means clustering method on the pixel represented images to obtain the cluster centers, with which we characterize WCE images as words-based color histograms. Then, we judge the status of a WCE frame by applying the support vector machine (SVM) and K-nearest neighbor methods. Comprehensive experimental results reveal that the best classification performance is obtained with YCbCr color space, cluster number 80 and the SVM. The achieved classification performance reaches 95.75% in accuracy, 0.9771 for AUC, validating that the proposed scheme provides an exciting performance for bleeding classification. Second, we propose a two-stage saliency map extraction method to highlight bleeding regions, where the first-stage saliency map is created by means of different color channels mixer and the second-stage saliency map is obtained from the visual contrast. Followed by an appropriate fusion strategy and threshold, we localize the bleeding areas. Quantitative as well as qualitative results show that our methods could differentiate the bleeding areas from neighborhoods correctly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Video Google: a text retrieval approach to object matching in videos
Sivic, & Zisserman (2003) · Proceedings Ninth IEEE International Conference on Computer Vision · doi:10.1109/iccv.2003.1238663 · Cited by 6,367
An efficient k-means clustering algorithm: analysis and implementation
Kanungo, T., Mount, D. M., Netanyahu, N. S., Piatko, C. D., Silverman, R., & Wu, A. Y. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2002.1017616 · Cited by 5,660
Visual categorization with bags of keypoints
Csurka, G. (2004) · European Conference on Computer Vision · Cited by 5,030
Locality-constrained Linear Coding for image classification
Wang, J., Yang, J., Yu, K., Lv, F., Huang, T., & Gong, Y. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5540018 · Cited by 3,100
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Linear spatial pyramid matching using sparse coding for image classification
Yang, J., Yu, K., Gong, Y., & Huang, T. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206757 · Cited by 2,828 · cited 3×
“HSV YCbCr [10] [11] [28] [29] Our”
BackgroundMethodInfluentialContext-Aware Saliency Detection
Goferman, S., Zelnik-Manor, L., & Tal, A. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.272 · Cited by 1,567
The Distance-Weighted k-Nearest-Neighbor Rule
Dudani, S. A. (1976) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1976.5408784 · Cited by 1,471
Salient Region Detection and Segmentation
Achanta, R., Estrada, F., Wils, P., & Süsstrunk, S. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-79547-6_7 · Cited by 844 · cited 1×
“In addition, natural saliency lies in the visual contrast [17], [18].”
BackgroundColorimetry: Understanding the CIE System
(2007) · Wiley eBooks · doi:10.1002/9780470175637 · Cited by 708
Colorimetry: understanding the CIE system
(2008) · Choice Reviews Online · doi:10.5860/choice.45-3204 · Cited by 575 · cited 2×
“where A(x, y) represents the “A” channel of the CIELAB color space [23], while M(x, y) is the “M” channel of the CMYK color space [24].”
BackgroundSharma, G., & Trussell, H. J. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.597268 · Cited by 440
Visual categorization with bags of keypoints
Duygulu, P. (2002) · European Conference on Computer Vision · Cited by 258
Computer-Aided Detection of Bleeding Regions for Capsule Endoscopy Images
Li, B., & Meng, M. Q.-H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010526 · Cited by 223
Self-citationComputer-Aided Bleeding Detection in WCE Video
Fu, Y., Zhang, W., Mandal, M., & Meng, M. Q.-H. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2257819 · Cited by 183
Self-citationM2A™ Capsule Endoscopy: A Breakthrough Diagnostic Tool for Small Intestine Imaging
Yu, M. (2002) · Gastroenterology Nursing · doi:10.1097/00001610-200201000-00007 · Cited by 121
Capsule endoscopy: Where are we after 6 years of clinical use?
Pennazio, M. (2006) · Digestive and Liver Disease · doi:10.1016/j.dld.2006.09.007 · Cited by 108 · cited 1×
“One problem is that the WCE produces about 55 000 images for each patient’s examination, which makes it hard for physicians to go through all these images frame by frame to locate the bleedings [6] in the GI tract.”
BackgroundHepatic Vessel Segmentation for 3D Planning of Liver Surgery
Conversano, F., Franchini, R., Demitri, C., Massoptier, L., Montagna, F., Maffezzoli, A., Malvası, A., & Casciaro, S. (2011) · Academic Radiology · doi:10.1016/j.acra.2010.11.015 · Cited by 67 · cited 1×
“The three metrics used in this experiment are precision, the false positive ratio (FPR), and the false negative ratio (FNR) [25], [26], which are calculated according to the following formulas:”
MethodReduction of bias and variance for evaluation of computer‐aided diagnostic schemes
Li, Q., & Doi, K. (2006) · Medical Physics · doi:10.1118/1.2179750 · Cited by 66 · cited 1×
“To be mentioned here, we apply a tenfold cross validation method to validate our proposed method [27].”
MethodLv, G., Yan, G., & Wang, Z. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091638 · Cited by 65
Categorization and Segmentation of Intestinal Content Frames for Wireless Capsule Endoscopy
Seguí, S., Drozdzal, M., Vilariño, F., Malagelada, C., Azpiroz, F., Radeva, P. I., & Vitria, J. M. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2221472 · Cited by 54
Frequency domain infrared watermarking for printed CMYK image
Zhao, Y., Fan, Z., & Hoover, M. E. (2011) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2011.6116232 · Cited by 8 · cited 2×
“where A(x, y) represents the “A” channel of the CIELAB color space [23], while M(x, y) is the “M” channel of the CMYK color space [24].”
Background
Cited by
Dynamics of information diffusion and its applications on complex networks
Zhang, Z.-K., Liu, C., Zhan, X.-X., Lu, X., Zhang, C.-X., & Zhang, Y.-C. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.07.002 · Cited by 484
Tahir, M., Naeem, A., Malik, H., Tanveer, J., Naqvi, R. A., & Lee, S.-W. (2023) · Cancers · doi:10.3390/cancers15072179 · Cited by 240
“We used 579 images of the melanoma class, and histopathology verified the diagnoses for all these images.”
MethodA deep convolutional neural network for bleeding detection in Wireless Capsule Endoscopy images
Jia, X., & Meng, M. Q.-H. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590783 · Cited by 201
“(a)-(c): The comparison of recall, precision and F1 score amongst [3], [21] and our method.”
BackgroundMethodResultSelf-citationArtificial intelligence in gastroenterology: A state-of-the-art review
Kröner, P. T., Engels, M. M., Glicksberg, B. S., Johnson, K. W., Mzaik, O., van Hooft, J. E., Wallace, M. B., El-Serag, H. B., & Krittanawong, C. (2021) · World Journal of Gastroenterology · doi:10.3748/wjg.v27.i40.6794 · Cited by 165
Metadata
- Authors
- Yuan, Y., Li, B., & Meng, M. Q.-H.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2016-03
- Volume
- 20
- Issue
- 2
- Pages
- 624-630
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1996498812
- Cited by
- 167
- References
- 25
- FWCI
- 14.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.