CoChat

BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability

Thomas, Simi Susan, Nathan, Viswam, Zong, Chengzhi, Soundarapandian, Karthikeyan, Shi, Xiangrong, Jafari, Roozbeh · 2016 · IEEE Journal of Biomedical and Health Informatics
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Noninvasive continuous blood pressure (BP) monitoring is not yet practically available for daily use. Challenges include making the system easily wearable, reducing noise level and improving accuracy. Variations in each person's physical characteristics, as well as the possibility of different postures, increase the complexity of continuous BP monitoring, especially outside the hospital. This study attempts to provide an easily wearable solution and proposes training to specific posture and individual for further improving accuracy. The wrist watch-based system we developed can measure electrocardiogram and photoplethysmogram. From these two signals, we measure pulse transit time through which we can obtain systolic and diastolic blood pressure through regression techniques. In this study, we investigate various functions to perform the training to obtain blood pressure. We validate measurements on different postures and subjects, and show the value of training the device to each posture and each subject. We observed that the average RMSE between the measured actual systolic BP and calculated systolic BP is between 7.83 to 9.37 mmHg across 11 subjects. The corresponding range of error for diastolic BP is 5.77 to 6.90 mmHg. The system can also automatically detect the arm position of the user using an accelerometer with an average accuracy of 98%, to make sure that the sensor is kept at the proper height. This system, called BioWatch, can potentially be a unified solution for heart rate, SPO2 and continuous BP monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2015.2458779

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Thomas, S. S., Nathan, V., Zong, C., Soundarapandian, K., Shi, X., & Jafari, R.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2016-09
Volume
20
Issue
5
Pages
1291-1300
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2341394157
Cited by
140
References
1
FWCI
5.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability. https://app.cochat.ai/papers/10.1109/jbhi.2015.2458779
The paper
Thomas, S. S., Nathan, V., Zong, C., Soundarapandian, K., Shi, X., & Jafari, R. (2016). BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2015.2458779

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.