Automatic Screening of Sleep Apnea Patients Based on the SpO2 Signal
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objective: This paper presents a methodology to automatically screen for sleep apnea based on the detection of apnea and hypopnea events in the blood oxygen saturation (SpO2) signal. Methods: It starts by detecting all desaturations in the SpO2signal. From these desaturations, a total of 143 time-domain features are extracted. After feature selection, the six most discriminative features are used to construct classifiers to predict if desaturations are caused by respiratory events. From these, a random forest classifier yielded the best classification performance. The number of desaturations, classified as caused by respiratory events per hour of recording, can then be used as an estimate of the apnea-hypopnea index (AHI), and to predict whether or not a patient suffers from sleep apneahypopnea syndrome (SAHS). All classifiers were developed based on a subset of 500 subjects of the Sleep Heart Health Study (SHHS) and tested on three different datasets, containing 8052 subjects in total. Results: An averaged desaturation classification accuracy of 82.8% was achieved over the different test sets. Subjects having SAHS with an AHI greater than 15 can be detected with an average accuracy of 87.6%. Conclusion: The achieved SAHS screening outperforms SpO2methods from the literature on the SHHS test dataset. Moreover, the robustness of the method was shown when tested on different independent test sets. Significance: These results show that an algorithm based on simple features of SpO2desaturations can outperform more elaborate methods in the detection of apneic events and the screening of SAHS patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Increased Prevalence of Sleep-Disordered Breathing in Adults
Peppard, P. E., Young, T., Barnet, J. H., Palta, M., Hagen, E. W., & Hla, K. M. (2013) · American Journal of Epidemiology · doi:10.1093/aje/kws342 · Cited by 4,618
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244 · cited 1×
“On top of the sleepiness, patients with SAHS have an increased risk of developing cardiovascular comorbidities [2]–[4].”
BackgroundRobust regression using iteratively reweighted least-squares.
Holland, P. W., & Welsch, R. E. (1977) · Communications in Statistics - Theory and Methods · doi:10.1080/03610927708827533 · Cited by 2,115 · cited 1×
“order to counteract these limitations, a robust linear regression is performed [41], using the robustfitMatlab function, between the annotated and computed AHI of the training set.”
MethodObstructive sleep apnoea and its cardiovascular consequences
Bradley, T. D., & Floras, J. S. (2009) · The Lancet · doi:10.1016/s0140-6736(08)61622-0 · Cited by 1,385
The Sleep Heart Health Study: Design, Rationale, and Methods
(1997) · Sleep · doi:10.1093/sleep/20.12.1077 · Cited by 1,331
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327 · cited 1×
“manual scoring of respiratory events suffers from intra and inter scorer variability, which has a negative impact on the degree of agreement [42].”
BackgroundWatanabe, E., Kiyono, K., Matsui, S., Somers, V. K., Sano, K., Hayano, J., Ichikawa, T., Kawai, M., Harada, M., & Ozaki, Y. (2017) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2016.09.004 · Cited by 34
Cited by
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00373-5 · Cited by 125
“7 Mx Percentage of the signal at least x% below median oxygen saturation, by default x= 2, used by Deviaene et al.(22) %”
MethodInfluentialO’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“Time series variables such as mean SpO2, variance of SpO2, minimum SpO2 and cumulative time with a saturation below a predetermined level can be measured and plotted graphically (43).”
BackgroundBehar, J. A., Palmius, N., Zacharie, S., Chocron, A., Penzel, T., Bittencourt, L., & Tufik, S. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab8856 · Cited by 20
Getting More from the Sleep Recording
McNicholas, W. T. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.001 · Cited by 3
Metadata
- Authors
- Deviaene, M., Testelmans, D., Buyse, B., Borzee, P., Van Huffel, S., & Varon, C.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2019-03
- Volume
- 23
- Issue
- 2
- Pages
- 607-617
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2793659206
- Cited by
- 75
- References
- 10
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.