Multiscaled Fusion of Deep Convolutional Neural Networks for Screening Atrial Fibrillation From Single Lead Short ECG Recordings
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Atrial fibrillation (AF) is one of the most common sustained chronic cardiac arrhythmia in elderly population, associated with a high mortality and morbidity in stroke, heart failure, coronary artery disease, systemic thromboembolism, etc. The early detection of AF is necessary for averting the possibility of disability or mortality. However, AF detection remains problematic due to its episodic pattern. In this paper, a multiscaled fusion of deep convolutional neural network (MS-CNN) is proposed to screen out AF recordings from single lead short electrocardiogram (ECG) recordings. The MS-CNN employs the architecture of two-stream convolutional networks with different filter sizes to capture features of different scales. The experimental results show that the proposed MS-CNN achieves 96.99% of classification accuracy on ECG recordings cropped/padded to 5 s. Especially, the best classification accuracy, 98.13%, is obtained on ECG recordings of 20 s. Compared with artificial neural network, shallow single-stream CNN, and VisualGeometry group network, the MS-CNN can achieve the better classification performance. Meanwhile, visualization of the learned features from the MS-CNN demonstrates its superiority in extracting linear separable ECG features without hand-craft feature engineering. The excellent AF screening performance of the MS-CNN can satisfy the most elders for daily monitoring with wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Very Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Deep learning in neural networks: an overview
Schmidhuber, J. (2015) · Neural Networks · doi:10.1016/j.neunet.2014.09.003 · Cited by 18,570
(2010) · Cited by 8,261
Two-Stream Convolutional Networks for Action Recognition in Videos
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1406.2199 · Cited by 6,756
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
An overview of gradient descent optimization algorithms
Ruder, S. (2016) · arXiv · doi:10.48550/arxiv.1609.04747 · Cited by 4,962
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
Convolutional Two-Stream Network Fusion for Video Action Recognition
Feichtenhofer, C., Pinz, A., & Zisserman, A. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.213 · Cited by 2,684
On the momentum term in gradient descent learning algorithms
Qian, N. (1999) · Neural Networks · doi:10.1016/s0893-6080(98)00116-6 · Cited by 2,312
Guidelines for the management of atrial fibrillation
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · EP Europace · doi:10.1093/europace/euq350 · Cited by 1,747
On optimization methods for deep learning
Ngiam, J., Coates, A., Lahiri, A., Prochnow, B., Le, Q. V., & Ng, A. Y. (2011) · International Conference on Machine Learning · Cited by 1,076
Gated Feedback Recurrent Neural Networks
Chung, J., Gulcehre, C., Cho, K., & Bengio, Y. (2015) · arXiv · doi:10.48550/arxiv.1502.02367 · Cited by 583 · cited 1×
“However, the gradient saturation problem exists in common used activation function, such as sigmoid [24] and tanh [25].”
Pourbabaee, B., Roshtkhari, M. J., & Khorasani, K. (2018) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2017.2705582 · Cited by 411
Automatic Real Time Detection of Atrial Fibrillation
Dash, S., Chon, K. H., Lu, S., & Raeder, E. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9740-z · Cited by 313
Zhong, Z., Jin, L., & Xie, Z. (2015) · 2015 13th International Conference on Document Analysis and Recognition (ICDAR) · doi:10.1109/icdar.2015.7333881 · Cited by 309
On the Performance of GoogLeNet and AlexNet Applied to Sketches
Ballester, P., & Araujo, R. (2016) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v30i1.10171 · Cited by 308
The signal-averaged P wave duration: A rapid and noninvasive marker of risk of atrial fibrillation
Guidera, S. A., & Steinberg, J. S. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90381-a · Cited by 233
A Novel Method for Detection of the Transition Between Atrial Fibrillation and Sinus Rhythm
Huang, C., Ye, S., Chen, H., Li, D., He, F., & Tu, Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2096506 · Cited by 185
A Simple Method to Detect Atrial Fibrillation Using RR Intervals
Lian, J., Wang, L. Y., & Muessig, D. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.01.028 · Cited by 175
Prevention of Cardiovascular Events in Elderly People
Andrawes, W. F., Bussy, C., & Belmin, J. (2005) · Drugs & Aging · doi:10.2165/00002512-200522100-00005 · Cited by 104
AF Detection and ECG Classification�based on Convolutional Recurrent Neural Network
Limam, M., & Precioso, F. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.171-325 · Cited by 80
Impact of the presence of noise on RR interval-based atrial fibrillation detection
Oster, J., & Clifford, G. D. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2015.08.013 · Cited by 64
Atrial fibrillation detection by multi-scale convolutional neural networks
Yao, Z., Zhu, Z., & Chen, Y. (2017) · International Conference on Information Fusion (FUSION) · doi:10.23919/icif.2017.8009782 · Cited by 50
Detection and delineation of P and T waves in 12‐lead electrocardiograms
Mehta, S. S., Lingayat, N. S., & Sanghvi, S. (2009) · Expert Systems · doi:10.1111/j.1468-0394.2008.00486.x · Cited by 31
Cited by
Yao, Q., Wang, R., Fan, X., Liu, J., & Li, Y. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.06.024 · Cited by 469
Self-citationA review on deep learning methods for ECG arrhythmia classification
Ebrahimi, Z., Loni, M., Daneshtalab, M., & Gharehbaghi, A. (2020) · Expert Systems with Applications: X · doi:10.1016/j.eswax.2020.100033 · Cited by 447
LSTM-Based ECG Classification for Continuous Monitoring on Personal Wearable Devices
Saadatnejad, S., Oveisi, M., & Hashemi, M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2911367 · Cited by 406
Feature-level fusion approaches based on multimodal EEG data for depression recognition
Cai, H., Qu, Z., Li, Z., Zhang, Y., Hu, X., & Hu, B. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.01.008 · Cited by 347
Murat, F., Yildirim, O., Talo, M., Baloglu, U. B., Demir, Y., & Acharya, U. R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103726 · Cited by 326
Metadata
- Authors
- Fan, X., Yao, Q., Cai, Y., Miao, F., Sun, F., & Li, Y.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-11
- Volume
- 22
- Issue
- 6
- Pages
- 1744-1753
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2887119478
- Cited by
- 323
- References
- 29
- FWCI
- 19.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.