CoChat

A Residual Based Attention Model for EEG Based Sleep Staging

Qu, Wei, Wang, Zhiyong, Hong, Hong, Chi, Zheru, Feng, David Dagan, Grunstein, Ron, Gordon, Christopher · 2020 · IEEE Journal of Biomedical and Health Informatics
Cited by 174

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Sleep staging is to score the sleep state of a subject into different sleep stages such as Wake and Rapid Eye Movement (REM). It plays an indispensable role in the diagnosis and treatment of sleep disorders. As manual sleep staging through well-trained sleep experts is time consuming, tedious, and subjective, many automatic methods have been developed for accurate, efficient, and objective sleep staging. Recently, deep learning based methods have been successfully proposed for electroencephalogram (EEG) based sleep staging with promising results. However, most of these methods directly take EEG raw signals as input of convolutional neural networks (CNNs) without considering the domain knowledge of EEG staging. Apart from that, to capture temporal information, most of the existing methods utilize recurrent neural networks such as LSTM (Long Short Term Memory) which are not effective for modelling global temporal context and difficult to train. Therefore, inspired by the clinical guidelines of sleep staging such as AASM (American Academy of Sleep Medicine) rules where different stages are generally characterized by EEG waveforms of various frequencies, we propose a multi-scale deep architecture by decomposing an EEG signal into different frequency bands as input to CNNs. To model global temporal context, we utilize the multi-head self-attention module of the transformer model to not only improve performance, but also shorten the training time. In addition, we choose residual based architecture which makes training end-to-end. Experimental results on two widely used sleep staging datasets, Montreal Archive of Sleep Studies (MASS) and sleep-EDF datasets, demonstrate the effectiveness and significant efficiency (up to 12 times less training time) of our proposed method over the state-of-the-art.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2020.2978004

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 174

Metadata

Authors
Qu, W., Wang, Z., Hong, H., Chi, Z., Feng, D. D., Grunstein, R., & Gordon, C.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2020-10
Volume
24
Issue
10
Pages
2833-2843
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W3009259306
Cited by
174
References
11
FWCI
12.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Residual Based Attention Model for EEG Based Sleep Staging. https://app.cochat.ai/papers/10.1109/jbhi.2020.2978004
The paper
Qu, W., Wang, Z., Hong, H., Chi, Z., Feng, D. D., Grunstein, R., & Gordon, C. (2020). A Residual Based Attention Model for EEG Based Sleep Staging. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2020.2978004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.