SkipDAEformer: A High-Precision Representation Learning Method for Removing Random Mixed Noise in MCG Signals
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Automated analytical techniques for magnetocardiography (MCG) are essential for diagnosing and predicting cardiovascular diseases. Clinically acquired MCG signals are often contaminated by various types of noise, which negatively impact subsequent signal analysis. However, traditional methods have limitations in denoising long-term MCG signals with complex spatial structures. We propose a high-precision, robust representation learning method based on skip connection multi-scale feature fusion (SkipDAEformer) for effectively removing random mixed noise in MCG signals. SkipDAEformer integrates attention fusion mechanisms into a basic denoising autoencoder to extract and fuse critical temporal and spatial information from each feature map, thus enhancing the model's ability to capture long-range dependencies and spatial features in MCG signals. Meanwhile, we further supplement and refine the semantic information for the feature maps through a global feature fusion method. By fusing multi-scale features from different skip connections, SkipDAEformer can learn more comprehensive representations of MCG signals, enabling the effective separation of clean signals from noise. Experimental results demonstrate that SkipDAEformer outperforms existing methods in denoising performance, channel consistency, feature consistency, and generalization ability and can be extended to a self-supervised learning framework. In actual noise reduction and diagnostic classification tasks, SkipDAEformer shows superior clinical acceptability and diagnostic value, potentially advancing MCG data analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Vaswani, A., Shazeer, N., Parmar, N., Uszkoreit, J., Jones, L., Gomez, A. N., Kaiser, L., & Polosukhin, I. (2017) · arXiv · doi:10.48550/arxiv.1706.03762 · Cited by 120,404 · cited 2×
“Due to the advantage of multi-head attention (MHA) in representing global features, the Transformer has achieved significant success in sequence analysis, such as machine translation and semantic segmentation [21], thereby contributing to the analysis of time series for MCG and ECG.”
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Exploiting Generative AI to Scale up Intelligent Tutoring Systems
Jakubův, J., Chvalovský, K., Goertzel, Z., Kaliszyk, C., Olšák, M., Piotrowski, B., Schulz, S., Suda, M., & Urban, J. (2023) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/lipics.itp.2023.19 · Cited by 76,658
Extracting and composing robust features with denoising autoencoders
Vincent, P., Larochelle, H., Bengio, Y., & Manzagol, P.-A. (2008) · Proceedings of the 25th international conference on Machine learning - ICML '08 · doi:10.1145/1390156.1390294 · Cited by 7,436
CBAM: Convolutional Block Attention Module
Woo, S., Park, J., Lee, J.-Y., & Kweon, I. S. (2018) · arXiv · doi:10.48550/arxiv.1807.06521 · Cited by 6,261 · cited 1×
“With the development of deep learning techniques, researchers have gradually introduced attention mechanisms in computer vision and time series analysis [17], [18].”
Swin-Unet: Unet-like pure transformer for medical image segmentation
Cao, H., Wang, Y., Chen, J., Jiang, D., Zhang, X., Tian, Q., & Wang, M. (2023) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-25066-8_9 · Cited by 5,640
MultiResUNet : Rethinking the U-Net architecture for multimodal biomedical image segmentation
Ibtehaz, N., & Rahman, M. S. (2020) · Neural Networks · doi:10.1016/j.neunet.2019.08.025 · Cited by 2,311 · cited 1×
“Specifically, meaningful semantic information in symmetric positions cannot be fully transferred to other asymmetric layers,resultinginincompletematchingofsemanticinformation acrosslayers[24].”
Chen, J., Mei, J., Li, X., Lu, Y., Yu, Q., Wei, Q., Luo, X., Xie, Y., Adeli, E., Wang, Y., et al. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103280 · Cited by 1,365 · cited 2×
“Additionally, incorporating Transformers [22], [39] in the latent space enhanced the expression of global features, thus improving denoising performance.”
Wang, H., Cao, P., Wang, J., & Zaiane, O. R. (2022) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v36i3.20144 · Cited by 1,111
Self-supervised Learning: Generative or Contrastive
Liu, X., Zhang, F., Hou, Z., Mian, L., Wang, Z., Zhang, J., & Tang, J. (2021) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2021.3090866 · Cited by 1,087 · cited 3×
“With the development of deep learning techniques, researchers have gradually introduced attention mechanisms in computer vision and time series analysis [17], [18].”
Network Representation Learning: A Survey
Zhang, D., Yin, J., Zhu, X., & Zhang, C. (2020) · IEEE Transactions on Big Data · doi:10.1109/tbdata.2018.2850013 · Cited by 714 · cited 1×
“Typically, the latent space provides a meaningful and high-quality feature representation [31], capturing specific attributes of the input data that allow for the distinction between clean and noisy signals.”
Laguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.648140 · Cited by 606 · cited 1×
“Following previous ECG studies [22], we used the QT Database (QTDB) [41] and the MIT-BIH Noise Stress Test Database (NSTDB) [42].”
Autoencoders and their applications in machine learning: a survey
Berahmand, K., Daneshfar, F., Salehi, E. S., Li, Y., & Xu, Y. (2024) · Artificial Intelligence Review · doi:10.1007/s10462-023-10662-6 · Cited by 593
Noise Reduction in ECG Signals Using Fully Convolutional Denoising Autoencoders
Chiang, H.-T., Hsieh, Y.-Y., Fu, S.-W., Hung, K.-H., Tsao, Y., & Chien, S.-Y. (2019) · IEEE Access · doi:10.1109/access.2019.2912036 · Cited by 363 · cited 2×
“Chiang et al. proposed a fully convolutional DAE model (FCN-DAE), which outperformed DAE models based on fully connected networks [16].”
Wang, H., Cao, P., Yang, J., & Zai͏̈ane, O. R. (2024) · Neural Networks · doi:10.1016/j.neunet.2024.106546 · Cited by 192
Self-supervised representation learning from 12-lead ECG data
Mehari, T., & Strodthoff, N. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105114 · Cited by 188
Lenis, G., Pilia, N., Loewe, A., Schulze, W. H. W., & Dössel, O. (2017) · Computational and Mathematical Methods in Medicine · doi:10.1155/2017/9295029 · Cited by 154 · cited 2×
“Referring to existing studies [27], [28], [29], we conducted quantitative analysis on electromyographic noise n EN , baseline drift n BW , industrial frequency interference n IN , and specific frequency noise n SN .”
Tao, R., Zhang, S., Huang, X., Tao, M., Ma, J., Ma, S., Zhang, C., Zhang, T., Tang, F., Lu, J., et al. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2877649 · Cited by 147 · cited 2×
“Furthermore, high-resolution MCG signals exhibit complex spatial structures, and spatial features (such as isomagnetic map and current density map features) are critical indicators for subsequent diagnostic classification [25], [26].”
Preprocessing and Denoising Techniques for Electrocardiography and Magnetocardiography: A Review
Jia, Y., Pei, H., Liang, J., Zhou, Y., Yang, Y., Cui, Y., & Xiang, M. (2024) · Bioengineering · doi:10.3390/bioengineering11111109 · Cited by 93
Self-citationSingh, P., & Sharma, A. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3197757 · Cited by 84
Pena, M. E., Pearson, C. L., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. B. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 70
Chen, M., Li, Y., Zhang, L., Liu, L., Han, B., Shi, W., & Wei, S. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3355960 · Cited by 66 · cited 7×
“For instance, Chen et al. [22] introduced the Transformer in the latent space for ECG denoising (TCDAE) and replaced the traditional convolution layer with a gated convolution layer.”
InfluentialA lightweight U-Net model for denoising and noise localization of ECG signals
Hu, L., Cai, W., Chen, Z., & Wang, M.-J. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105504 · Cited by 65 · cited 2×
“…used the mean absolute error (MAE) as the evaluation metric to assess featureconsistency[35],[36] ( MAE = | F − ˆ F | ) ,andaccuracy (Acc) and F1-score (F1) for diagnostic classification [19], [37], where F and ˆ F denote the features extracted from the clean and denoised MCG signals, respectively.”
Wacker‐Gussmann, A., Strasburger, J. F., & Wakai, R. T. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.025224 · Cited by 58 · cited 2×
“MCG is currently used in clinical research on coronary artery disease (CAD) [2], myocardial infarction [3], heart failure [4], and fetal arrhythmia [5].”
Chen, M., Cheng, Q., Feng, X., Zhao, K., Zhou, Y., Xing, B., Tang, S., Wang, R. L., Duan, J., Wang, J., et al. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105681 · Cited by 51 · cited 2×
“However, clinically acquired MCG signals are often contaminated by various types of noise, including electromyographic noise, baseline drift, industrial frequency interference, and specific frequency noise [8], which severely hinder subsequent signal analysis.”
Self-citationTwo-stage ECG signal denoising based on deep convolutional network
Qiu, L., Cai, W., Yu, J., Zhong, J., Wang, L., Li, W., Chen, Y., & Wang, L. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac34ea · Cited by 50 · cited 1×
“TheDAE-basedmodelswereCBAM-DAE[20],TCDAE[22],ACDAE[19],andFCN-DAE[16],and the U-Net-based models were LUnet [37], Ude-Net [40], Tran-sUNet [39], and Swin-UNet [38], all methods were adapted and evaluated for multi-channel MCG signals.”
Yen, C.-T., Chang, S., & Liao, C.-H. (2022) · IEEE Access · doi:10.1109/access.2022.3195857 · Cited by 45 · cited 1×
“Additionally, in the qualitative assessment, we used the mean absolute error (MAE) as the evaluation metric to assess featureconsistency[35],[36] ( MAE = | F − ˆ F | ) ,andaccuracy (Acc) and F1-score (F1) for diagnostic classification [19], [37], where F and ˆ F denote the features extracted from…”
Magnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42 · cited 2×
“…MCG sample: where t n , σ n , and b n control the center position, width and amplitude scaling of each random perturbation respectively, and σ n and b n are uniform random numbers with ranges of [1,10] and [1,5] respectively, and M denotes the number of random perturbations (randomly select 1-3).”
Mariyappa, N., Sengottuvel, S., Parasakthi, C., Gireesan, K., Janawadkar, M. P., Radhakrishnan, T. S., & Sundar, C. S. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.06.023 · Cited by 38 · cited 1×
“Referring to existing studies [27], [28], [29], we conducted quantitative analysis on electromyographic noise n EN , baseline drift n BW , industrial frequency interference n IN , and specific frequency noise n SN .”
Convolutional block attention autoencoder for denoising electrocardiograms
Chorney, W., Wang, H., He, L., Lee, S., & Fan, L. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105242 · Cited by 37
Tao, R., Zhang, S., Wang, Y., Mi, X., Ma, J., Shen, C., & Zheng, G. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3128169 · Cited by 32
BRAVEHEART: Open-source software for automated electrocardiographic and vectorcardiographic analysis
Stabenau, H. F., & Waks, J. W. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107798 · Cited by 32
Application of Wavelet Transform in MCG-signal Denoising
Dong, Y., Shi, H., Luo, J., Fan, G., & Zhang, C. (2010) · Modern Applied Science · doi:10.5539/mas.v4n6p20 · Cited by 29 · cited 1×
“Over time, methods like discrete wavelet transform (DWT) [11], empirical mode decomposition (EMD) [12], and variational mode decomposition (VMD) [8] have been introduced to improve MCG denoising.”
Han, X., Pang, J., Xu, D., Wang, R., Xie, F., Yang, Y., Sun, J., Li, Y., Li, R., Yin, X., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad0f70 · Cited by 25 · cited 2×
“Traditional techniques, such as infinite impulse response (IIR) and finite impulse response (FIR) filters, are commonly used for automatic MCG denoising [9], [10].”
Self-citationAn Integrated Maximum Current Density Approach for Noninvasive Detection of Myocardial Infarction
Zhao, C., Jiang, S., Wu, Y., Zhu, J., Zhou, D., Hailer, B., Grönemeyer, D. H. W., & Leeuwen, P. V. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2649570 · Cited by 22
Her, A., & Park, J. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1305 · Cited by 18
Liao, Y., He, C., & Guo, Q. (2018) · Symmetry · doi:10.3390/sym10070269 · Cited by 15 · cited 1×
“…Hz), with the amplitude and phase of each wave randomly selected, as follows [27]: n IN is caused by electromagnetic fields from powerlines or measurement equipment, which mainly include 50 Hz noise and its higher harmonics [30], as follows [28]: where and added them to the temporal modulation (Fig.”
Hu, Z., Lin, Y., Ye, K., & Lin, Q. (2022) · IEEE Access · doi:10.1109/access.2022.3193769 · Cited by 13
Lu, L., Yang, K. Y., Kong, X., Yang, R., & Wang, Y. (2018) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2018.2836931 · Cited by 11 · cited 2×
“Traditional techniques, such as infinite impulse response (IIR) and finite impulse response (FIR) filters, are commonly used for automatic MCG denoising [9], [10].”
Co-registration method of wearable magnetocardiography system and CT
Yang, Y., Liu, Z., Wang, R., Wang, Y., Han, X., Jia, Y., Jin, Z., Pang, J., Xie, F., Yu, D., et al. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106914 · Cited by 10 · cited 1×
“The rich spatial information in MCG signals can be applied to isomagnetic map reconstruction, current density estimation [6], and inverse solving in dipole models [7].”
Self-citationPatel, R., Kesavaraja, C., & Sengottuvel, S. (2023) · International Journal of Information Technology · doi:10.1007/s41870-023-01504-3 · Cited by 4 · cited 1×
“Over time, methods like discrete wavelet transform (DWT) [11], empirical mode decomposition (EMD) [12], and variational mode decomposition (VMD) [8] have been introduced to improve MCG denoising.”
Research works printed but not linked: 2
- Mao, 2016, Image restoration using very deep convolutional encoder-decoder networks with symmetric skip connections, 29, 2802
- Moody, 1984, A noise stress test for arrhythmia detectors, Comput. Cardiol., 11, 381
Cited by
Wang, R., Pang, J., Xu, D., Han, X., Yang, Y., Liu, Z., Wang, Y., Xiang, M., & Ning, X. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.129500 · Cited by 5
Self-citationJia, Y., Pei, H., Xu, D., Pang, J., Chen, Y., Shen, C., & Xiang, M. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108875 · Cited by 5
Self-citationEffects of Magnetocardiography Array Errors on Cardiac Source Imaging
Zhang, M., Wang, Y., Li, P., Zhang, Y., Cui, Y., & Xiang, M. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3676206 · Cited by 2
“These specifications are consistent with the structural parameters of the OPM-MCG system used in our laboratory [4], [33], [34].”
Self-citationPalantzas, A., & Anagnostouli, M. (2026) · Sensors · doi:10.3390/s26051738 · Cited by 1
“Complementarily, SkipDAEformer [78] advances the preprocessing stage by providing robust AI-driven noise suppression, improving signal quality prior to classification and thereby increasing the reliability of downstream MCG diagnostic models.”
Edge-aware multi-head transformer for noise-robust full-field magnetocardiography signal modeling
Wang, J., Shen, H., Guo, J., Xu, X., Liu, L., Ma, J., & Shen, C. (2026) · The Visual Computer · doi:10.1007/s00371-025-04260-6 · Cited by 1
“Early MCG studies relied on single-channel magnetome-ters whose time-domain averaging sacrificed all spatial detail for modest noise reduction [5, 7, 8].”
Metadata
- Authors
- Wang, R., Liu, Z., Pang, J., Sun, J., Xiang, M., & Ning, X.
- Affiliations
- Beihang University (CN)
- Shandong University (CN)
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2025-11
- Volume
- 29
- Issue
- 11
- Pages
- 8086-8099
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W4411203397
- Cited by
- 9
- References
- 40
- Citations by year
- 2026: 7 · 2025: 2
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Biomedical and Health Informatics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (U23A20485, 62101017)
- Innovation Program for Quantum Science and Technology (2021ZD0300503)
- Development and Application of UltraWeak Magnetic Measurement Technology based on Atomic Magnetometer (2022-189-181)
- Key R&D Program of Shandong Province (2022ZLGX03)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Keywords
- magnetocardiography, mixed noise removal, representation learning, denoising autoencoder, attention mechanism, skip connections, multi-scale feature fusion, global feature fusion, long-range dependencies, self-supervised learning, cardiovascular disease diagnosis
- MeSH terms
- Machine Learning, Algorithms, Cardiovascular Diseases, Electromyography, Humans, Signal Processing, Computer-Assisted, Magnetocardiography, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.