Miniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Existing practices for monitoring heart activity rely heavily on electrocardiography (ECG) approaches, which suffer from low accuracy (as electric fields get impacted by biological tissues); extensive diagnostic times; and lack of comfort (as electrodes are in direct contact with the human body). Though magnetocardiography (MCG) provides more accurate and localized signals while also being non-contact, state-of-the-art equipment for capturing such weak magnetic fields (i.e., SQUIDs) requires extensive shielding and is very expensive. MCG sensing devices that do not require shielding have been reported, but they are sbulky, heavy, and cumbersome to use. In this work, we take a major step forward and propose a novel, miniature, and low-cost MCG sensor for operation in non-shielded environments that breaks the state-of-the-art boundaries in terms of size and weight. Our sensor relies on novel coil design principles and Digital Signal Processing (DSP) algorithms to achieve: (a) 4.67 times smaller diameter, (b) 4.5 times smaller height, and (c) at least 216 times lighter weight than previous passive implementations. In vitro measurements demonstrate that a 4-coil sensor array with 15 minutes of recoding time is sufficient to capture human MCG signals. Discussions indicate that higher number of coils and longer recording times can be employed to improve the signal clarity and fit diverse clinical needs. The proposed coil sensor array provides a convenient method to diagnose several cardiac conditions, such as myocardial ischemia, arrhythmia, right atrial hypertrophy, right ventricular hypertrophy, and the Brugada syndrome.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Further preliminary research using a novel miniature induction coil array and digital signal processing algorithms to record unshielded MCG from a “simulated heart” (267) and to calculate heart rate variability under cognitive workload in healthy volunteers (268) has been recently reported.”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [267]
Citations
Cites
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Linzer, M., Yang, E. H., Estes III, N. A. M., Wang, P., Vorperian, V. R., & Kapoor, W. N. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-12-199706150-00012 · Cited by 437
A Review of Fetal ECG Signal Processing Issues and Promising Directions
Sameni (2010) · The Open Pacing, Electrophysiology & Therapy Journal · doi:10.2174/1876536x01003010004 · Cited by 410
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Measuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Experimental methods in magnetism
Zijlstra, H. (1967) · CERN Document Server (European Organization for Nuclear Research) · Cited by 209
Frequency content and characteristics of ventricular conduction
Tereshchenko, L. G., & Josephson, M. E. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2015.08.034 · Cited by 177
Lin, C.-H. (2008) · Computers & Mathematics with Applications · doi:10.1016/j.camwa.2007.04.035 · Cited by 177
Research works printed but not linked: 1
- 0, Elekta technology virtually eliminates MEG helium refills, Elekta AB
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Many efforts have been made to develop such kinds of mag-netometers, such as the induction coil magnetometer ( 28 ), fluxgate magnetometers ( 29 ), and magnetoresistive magnetometers ( 30 , 31 ).”
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Quantum magnetic gradiometer with entangled twin light beams
Wu, S., Bao, G., Guo, J., Chen, J., Du, W., Shi, M., Yang, P., Chen, L. Q., & Zhang, W. (2023) · Science Advances · doi:10.1126/sciadv.adg1760 · Cited by 60
A Review of Magnetic Field Emissions From the Human Body: Sources, Sensors, and Uses
Zhu, K., & Kiourti, A. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3186643 · Cited by 44
Self-citationWang, Y., Zhao, Z., Chai, Z., Fang, J., & Chen, M. (2023) · The FASEB Journal · doi:10.1096/fj.202300201rr · Cited by 27
Dong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 15
Suppression of spin-exchange relaxation in Bell-Bloom magnetometer
Fang, C., Jiang, L., Liu, J., Chen, Y., Zhu, J., Shao, Q., Zou, Y., Xiang, M., & Quan, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.115695 · Cited by 14
Quantifying Cognitive Workload Using a Non-Contact Magnetocardiography (MCG) Wearable Sensor
Wang, Z., Zhu, K., Kaur, A., Recker, R. S., Yang, J. G., & Kiourti, A. (2022) · Sensors · doi:10.3390/s22239115 · Cited by 13
Self-citationZhu, K., & Kiourti, A. (2022) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2022.3187315 · Cited by 9
Self-citationReal-Time Magnetocardiography with Passive Miniaturized Coil Array in Earth Ambient Field
Zhu, K., & Kiourti, A. (2023) · Sensors · doi:10.3390/s23125567 · Cited by 8
Self-citationMeasurement of T wave in magnetocardiography using tunnel magnetoresistance sensor
Lu, Z., Ji, S., & Yang, J. (2022) · Chinese Physics B · doi:10.1088/1674-1056/aca5fe · Cited by 7
Kaiss, A., Islam, M. A., & Kiourti, A. (2024) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2024.3426270 · Cited by 6
Self-citationSERF-like magnetometry in room-temperature environment
Bao, G., Chen, J., Wang, R., Chen, L. Q., & Zhang, W. (2023) · Optics Express · doi:10.1364/oe.500875 · Cited by 6
Cheng, H., Liu, R., Fang, S., Li, Z., Zhang, D., Zhang, X., Chen, W., Chen, H., Kang, L., Wang, J., et al. (2024) · Chemical Communications · doi:10.1039/d3cc06321f · Cited by 4
Air-core Coil Gradiometer for Biomagnetic Sensing in Non-shielded Environments
Zhu, K., & Kiourti, A. (2021) · United States National Committee of URSI National Radio Science Meeting · doi:10.23919/usnc-ursinrsm51531.2021.9336443 · Cited by 3
Self-citationKaiss, A., Yang, J. G., & Kiourti, A. (2025) · Sensors · doi:10.3390/s25154806 · Cited by 2
Self-citationPartial Shielding to Improve Sensitivity of a Fully Passive Bio-Magnetic Signal Detection System
Zhu, K., & Kiourti, A. (2023) · doi:10.23919/aces57841.2023.10114779 · Cited by 2
Self-citationNoise Coil For Improving Sensitivity in a Fully Passive Bio-Magnetic Signal Detection System
Zhu, K., & Kiourti, A. (2023) · doi:10.23919/aces57841.2023.10114693 · Cited by 1
Self-citationZhu, K., & Kiourti, A. (2023) · doi:10.23919/aces57841.2023.10114791
Self-citationNoise Coil For Improving Sensitivity in a Fully Passive Bio-Magnetic Signal Detection System
Zhu, K., & Kiourti, A. (2023) · doi:10.23919/aces57841.2023.10114790
Self-citationMathematical Modelling of Magnetocardiography Signals from Cardiac Sources
Reshma, H., Anu, K. V., Bhat, V. R., & Anitha, H. (2024) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt61001.2024.10725098
Reconstructing Magnetocardiography (MCG) Waveforms From Wearable Sensors Using Phase Retrieval
Kaiss, A., Lee, K., & Kiourti, A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3692631
Self-citationSong, X., Chen, D., Li, G., Du, Q., Pan, M., Ding, Q., Shi, S., Hu, Y., Hu, J., & Li, P. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3747119
Metadata
- Authors
- Zhu, K., Shah, A. M., Berkow, J., & Kiourti, A.
- Affiliations
- The Ohio State University (US)
- Triton Systems (United States) (US)
- Venue
- IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Published
- 2021-06
- Volume
- 5
- Issue
- 2
- Pages
- 124-131
- ISSN
- 2469-7249 (ISSN-L)
- 2469-7257
- OpenAlex
- W3081900447
- Cited by
- 22
- References
- 38
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2023: 11 · 2022: 4 · 2021: 1
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology (publishedVersion)
- Funders
- Defense Health Agency
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- coil array, digital signal processing, arrhythmia detection, myocardial ischemia, Brugada syndrome, right ventricular hypertrophy, right atrial hypertrophy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.