CoChat

Miniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments

Zhu, Keren, Shah, Adhvait M., Berkow, Jan, Kiourti, Asimina · 2021 · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Existing practices for monitoring heart activity rely heavily on electrocardiography (ECG) approaches, which suffer from low accuracy (as electric fields get impacted by biological tissues); extensive diagnostic times; and lack of comfort (as electrodes are in direct contact with the human body). Though magnetocardiography (MCG) provides more accurate and localized signals while also being non-contact, state-of-the-art equipment for capturing such weak magnetic fields (i.e., SQUIDs) requires extensive shielding and is very expensive. MCG sensing devices that do not require shielding have been reported, but they are sbulky, heavy, and cumbersome to use. In this work, we take a major step forward and propose a novel, miniature, and low-cost MCG sensor for operation in non-shielded environments that breaks the state-of-the-art boundaries in terms of size and weight. Our sensor relies on novel coil design principles and Digital Signal Processing (DSP) algorithms to achieve: (a) 4.67 times smaller diameter, (b) 4.5 times smaller height, and (c) at least 216 times lighter weight than previous passive implementations. In vitro measurements demonstrate that a 4-coil sensor array with 15 minutes of recoding time is sufficient to capture human MCG signals. Discussions indicate that higher number of coils and longer recording times can be employed to improve the signal clarity and fit diverse clinical needs. The proposed coil sensor array provides a convenient method to diagnose several cardiac conditions, such as myocardial ischemia, arrhythmia, right atrial hypertrophy, right ventricular hypertrophy, and the Brugada syndrome.

Overview

Integrity signals

Registry

Crossref · 10.1109/jerm.2020.3019891

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. 0, Elekta technology virtually eliminates MEG helium refills, Elekta AB

Cited by

See all 22

Metadata

Authors
Zhu, K., Shah, A. M., Berkow, J., & Kiourti, A.
Affiliations
  • The Ohio State University (US)
  • Triton Systems (United States) (US)
Venue
IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Published
2021-06
Volume
5
Issue
2
Pages
124-131
ISSN
  • 2469-7249 (ISSN-L)
  • 2469-7257
OpenAlex
W3081900447
Cited by
22
References
37
Citations by year
2026: 1 · 2025: 1 · 2024: 4 · 2023: 11 · 2022: 4 · 2021: 1
FWCI
1.37
Type
journal article
Language
en
Open access
closed
Locations
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology (publishedVersion)
Funders
Defense Health Agency
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
Keywords
coil array, digital signal processing, arrhythmia detection, myocardial ischemia, Brugada syndrome, right ventricular hypertrophy, right atrial hypertrophy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.