Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This paper investigates the stability of offshore wind farms integration through a modular multilevel converter-based high-voltage dc (MMC-HVdc) transmission system. Resonances or instability phenomena have been reported in between wind farms and MMC-HVdc systems. They are arguably originated due to interactions between the MMC and the wind power inverters. However, the nature of these interactions is neither well understood nor reported in the literature. In this paper, the impedance-based analytical approach is applied to analyze the stability and to predict the phase margin of the interconnected system. For that, analytical impedance models of a three-phase MMC in a compensated modulation case and a direct modulation case are separately derived using the small-signal frequency domain method. Moreover, the impedance models of the MMC take the circulating current control into account. The derived impedance models are then verified by comparing the frequency responses of the analytical model with the impedance measured in a nonlinear time-domain simulation model developed in MATLAB. The results show that the potential resonances or instability of the interconnected system can be readily predicted through the Nyquist diagrams. In addition, the analysis indicates that the circulating current control of the MMC has a significant impact on the stability of the interconnected system. Finally, the time-domain simulations validate the theoretical analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346 · cited 1×
“AMODULAR multilevel converter-based high-voltage dc (MMC-HVdc) transmission technology has become a promising solution for the grid integration of large-scale offshore wind farms, due to its advantages, such as modular design, high efficiency, low distortion of output voltage, easily scalable in terms of voltage level…”
BackgroundAnalysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334 · cited 1×
“The d–q impedances of two-level grid-connected inverters with feedback control and PLL were derived and measured in [20]–[22], and an impedance-based stability analysis for three-phase gridconnected paralleled converters was performed in [22].”
MethodDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“AMODULAR multilevel converter-based high-voltage dc (MMC-HVdc) transmission technology has become a promising solution for the grid integration of large-scale offshore wind farms, due to its advantages, such as modular design, high efficiency, low distortion of output voltage, easily scalable in terms of voltage level…”
BackgroundImpedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167 · cited 3×
“VSCs have been well investigated in [19], so the results of the paper have been used for the impedance modeling of the wind power inverter in this paper.”
BackgroundMethodInput-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117 · cited 1×
“Most research has so far focused on the impedance modeling of two-level converters [18]–[26].”
BackgroundModeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785 · cited 2×
“Moreover, the Nyquist map is also able to demonstrate the impact of system parameters on stability, which has a great significance in designing a power electronics-based system [17].”
BackgroundMethodSmall-Signal Methods for AC Distributed Power Systems–A Review
Sun, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029859 · Cited by 712 · cited 1×
“of the d–q impedance-based stability analysis is that it can only detect whether the system is stable or not, but cannot determine the stability margin [27].”
BackgroundDynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 5×
“, v d = vdu −vdl, for a three-phase MMC, v d = 0 [4].”
BackgroundMethodInfluential
Cited by
Lyu, J., Zhang, X., Cai, X., & Molinas, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2842682 · Cited by 345
Self-citationModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“[40] and [41] are two of the first attempts to develop impedance models of three-phase MMCs valid for power system stability studies.”
BackgroundSequence Impedance Modeling of Modular Multilevel Converters
Sun, J., & Liu, H. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2762408 · Cited by 287
“Reference [14] reported MMC impedance models and HVDC system analysis using the methods described in [7], [10], and [12].”
BackgroundMethodLyu, J., Cai, X., & Molinas, M. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2759096 · Cited by 194
“Moreover, the internal dynamics of MMC such as capacitor voltage fluctuations and harmonic circulating currents may have harmful effects on the stable operation of MMC-based interconnected systems, especially for renewable energy integration applications [5], [6].”
BackgroundMethodSelf-citationSub‐synchronous oscillation mechanism and its suppression in MMC‐based HVDC connected wind farms
Lyu, J., Cai, X., Amin, M., & Molinas, M. (2017) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2017.1066 · Cited by 138
Self-citationXue, T., Lyu, J., Wang, H., & Cai, X. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3074798 · Cited by 123
Self-citationStability and control of mixed AC–DC systems with VSC‐HVDC: a review
Shah, R., Sánchez, J. C., Preece, R., & Barnes, M. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2017.1140 · Cited by 118
Coordinated Control of Parallel DR-HVDC and MMC-HVDC Systems for Offshore Wind Energy Transmission
Li, R., Yu, L., Xu, L., & Adam, G. P. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931197 · Cited by 112
“One common approach is to use the offshore MMC to form the offshore ac grid with fixed frequency control [1], [2].”
MethodShao, B., Zhao, S., Yang, Y., Gao, B., & Blaabjerg, F. (2020) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2020.3035203 · Cited by 110
“As the impact of controller parameters on the SSO characteristics has been analyzed in [25]–[41], this paper”
BackgroundMethodInfluentialImpact of Power Flow Direction on the Stability of VSC-HVDC Seen From the Impedance Nyquist Plot
Amin, M., Molinas, M., Lyu, J., & Cai, X. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608278 · Cited by 115
Self-citationImpedance Analysis of Modular Multi-Level Converters Connected to Weak AC Grids
Khazaei, J., Beza, M., & Bongiorno, M. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2779403 · Cited by 101
“A frequency-domain stability analysis of MMC-based HVDC system for wind farm integration was studied recently in [11].”
BackgroundMethodSelf-Synchronization of Wind Farm in an MMC-Based HVDC System: A Stability Investigation
Amin, M., Rygg, A., & Molinas, M. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2661540 · Cited by 99
“Many researches have been focused on modeling [38]–[41] and controlling the MMC for example, Model predictive control [42], [43], energy based control [37], PR regulator in stationary frame [5], PI controller in synchronous rotating frame [44], [45].”
BackgroundMethodSelf-citationAmin, M., & Molinas, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2840516 · Cited by 88
Self-citationImpedance-Based Stability Analysis of Voltage-Controlled MMCs Feeding Linear AC Systems
Wu, H., Wang, X., & Kocewiak, Ł. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2911654 · Cited by 88
“In some early works [6], [7], the internal dynamics of MMCs, i.”
BackgroundWang, C., Xu, J., Pan, X., Gong, W., Zhu, Z., & Xu, S. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3125699 · Cited by 83
Cheah-Mañé, M., Sainz, L., Liang, J., Jenkins, N., & Ugalde‐Loo, C. E. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2663111 · Cited by 77
“If the VSC uses a MMC topology, high frequency filters are not required and only a voltage control loop is considered [18], [21].”
BackgroundFuzzy Logic Based Adaptive Droop Control in Multiterminal HVDC for Wind Power Integration
Chen, X., Wang, L., Sun, H., & Chen, Y. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2697967 · Cited by 66
“An impedance-based analytical approach is implemented to investigate the stability of a wind farm interconnection through a MMC-HVDC system [19], [20].”
MethodYu, L., Xu, L., Zhu, J., & Li, R. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3065572 · Cited by 65
Zhu, J., Hu, J., Wang, S., & Wan, M. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.2976776 · Cited by 63
“harmonic linearization [15]), linear time-periodic (LTP) method [16], dynamic phasor (DP) method [17]–[19], etc.”
MethodSequence Impedance Modeling and Analysis of MMC in Single-Star Configuration
Zhang, Y., Chen, X., & Sun, J. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2911998 · Cited by 60
Large-Signal Impedance-Based Modeling and Mitigation of Resonance of Converter-Grid Systems
Shah, S., Koralewicz, P., Gevorgian, V., Wallen, R., Jha, K., Mashtare, D., Burra, R. K., & Parsa, L. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2019.2903478 · Cited by 65
“To understand the underlying mechanism of resonance interactions, small-signal impedance models are developed for topologies ranging from two-level voltage source converters (VSCs) [12], [13] and modular multi-level converters [14], [15] to doublyfed induction generator (DFIG) based Type 3 wind turbines [16].”
BackgroundA Hybrid Modular Multilevel Converter Family With Higher Power Density and Efficiency
Liu, J., Dong, D., & Zhang, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3055690 · Cited by 60
“1 has emerged as one of the promising topologies in recent years for medium or high voltage industrial applications, such as high voltage dc transmission [1]–[3], static synchronous compensators [4], offshore renewable energy integration [5], solid state transformer [6], and medium voltage motor drives [7]–[9].”
BackgroundOn the Risk for Subsynchronous Control Interaction in Type 4 Based Wind Farms
Beza, M., & Bongiorno, M. (2018) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2889181 · Cited by 57
“2 can be employed for analysis purposes, where a variable current source is used to represent the machine side and the rectifier stage [23], [24].”
MethodBeza, M., & Bongiorno, M. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.04.004 · Cited by 56
Wu, S., & Liu, Z. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3049145 · Cited by 56
“In order to reveal the mechanism of APF on LFO suppression and assess the influence of APF on the stability of vehicle-grid system, the impedancebased stability analysis method with generalized Nyquist stability criterion (GNSC) and the system power consumption criterion are adopted [11]–[12].”
MethodKurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2763 · Cited by 57
Effect of Reactive Power Characteristic of Offshore Wind Power Plant on Low-Frequency Stability
Zhou, W., Wang, Y., Torres‐Olguin, R. E., & Chen, Z. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.2965017 · Cited by 55
“Furthermore, instability phenomena in a two-terminal VSC-HVDC system can be caused by high active power reference [13], [20].”
BackgroundZhang, Y., Yang, Y., Chen, X., & Gong, C. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3020434 · Cited by 55
“In the relevant analysis in the literature, the effects of operational conditions, the geographical distribution of WTGs, and transmission networks on the stability of wind farms were ignored by simplifying a wind farm into a single-converter connected to an infinite grid [8]–[14], [16], [17].”
BackgroundCapacitor Voltage Estimation Scheme With Reduced Number of Sensors for Modular Multilevel Converters
Abushafa, O. S. M., Gadoue, S. M., Dahidah, M. S. A., Atkinson, D. J., & Missailidis, P. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797245 · Cited by 53
“2797245 ing losses [2]–[8].”
Accurate and Efficient Estimation of Short-Circuit Current for MTDC Grids Considering MMC Control
Gao, S., Ye, H., & Liu, Y. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2946603 · Cited by 55
“The salient advantages of VSC-HVDC are the capability to manage power flow direction, immunity against commutation failure and easy extension to multi-terminal direct current (MTDC) grid [5], [6].”
BackgroundZong, H., Zhang, C., Lyu, J., Cai, X., Molinas, M., & Rao, F. (2020) · IEEE Access · doi:10.1109/access.2020.2981177 · Cited by 53
“[2] F. Deng, Q. Wang, D. Liu, Y. Wang, M. Cheng, and Z. Chen, ‘‘Reference submodule based capacitor monitoring strategy for modular multilevel converters,’’ IEEE Trans.”
BackgroundMethodSelf-citationBi, T., Li, J., Zhang, P., Mitchell-Colgan, E., & Xiao, S. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0994 · Cited by 50
Du, W., Ren, B., Wang, H. F., & Wang, Y. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2920416 · Cited by 46
Beza, M., & Bongiorno, M. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.105978 · Cited by 48
Shao, B., Zhao, S., Gao, B., Yang, Y., & Blaabjerg, F. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3028546 · Cited by 46
“At present, to analyze the small-signal stability of the DDWFV, the SEM is commonly used [15]–[19], but the ade-”
MethodStability and Sensitivity Analysis of Multi-Vendor, Multi-Terminal HVDC Systems
Liao, Y., Wu, H., Wang, X., Ndreko, M., Dimitrovski, R., & Winter, W. (2023) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2023.3234803 · Cited by 45
“As a consequence, a lot of research works have been carried out in recent years on the dynamical modeling and analysis of HVDC systems [7], [8], [9], [10].”
BackgroundTransfer Learning Based Online Impedance Identification for Modular Multilevel Converters
Zhang, M., Zhang, Y., & Xu, Q. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3299194 · Cited by 50
“MODULAR multilevel converters (MMC) have been widely adopted in high voltage DC (hvDC) transmission systems, electrical railway traction systems, and other medium voltage systems due to the advantages of the scalability, high efficiency, and low distortion [1], [2], [3].”
BackgroundBeza, M., Bongiorno, M., & Stamatiou, G. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2701415 · Cited by 44
“The authors in [16], [17], and [18] tried to derive the ac-side input admittances considering ac-side closed-loop voltage control.”
BackgroundZhang, Y., Wang, Y., Zhang, D., Chen, X., & Gong, C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3066631 · Cited by 46
“These sub and super-synchronous resonance problems can be analyzed by applying the impedance-based stability criterion to the developed output impedance model of the WTGs and the grid [5], [6].”
BackgroundHan, Y., Sun, H., Huang, B., Qin, S., Mu, Q., & Yu, Y. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3115248 · Cited by 43
Zeng, Y., Núñez, A. A., & Li, Z. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2022.109196 · Cited by 43
Investigation of Subsynchronous Oscillation in a DFIG-based Wind Power Plant Connected to MTDC Grid
Li, H., Shair, J., Zhang, J., & Xie, X. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3197185 · Cited by 54
Lyu, J., Rao, Y., Wang, Z., Dai, J., & Cai, X. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3333760 · Cited by 42
“The impedance-based analysis method has become one of mainstream methods to investigate the oscillatory stability of power systems with high-penetration renewables and HVDC systems [6], [7], thanks to its modular modeling, high scalability, measurableandsoon.”
MethodSelf-citationZhu, S., Liu, K., Liao, X., Qin, L., Huai, Q., Xu, Y., Li, Y., & Wang, F. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3010873 · Cited by 43
“MMC impedance modeling through the use of harmonic linearization is reported in [11], but some significant second harmonic dynamics are ignored in [11].”
BackgroundDeng, J., Cheng, F., Yao, L., Xu, J. B., Mao, B., Li, X., & Chen, R. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12894 · Cited by 41
Impedance modeling and analysis of modular multilevel converters
Sun, J., & Liu, H. (2016) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2016.7556781 · Cited by 43
“Due to the circulating current, each arm current in an MMC also contains significant harmonics, which are ignored in the models developed in [13].”
BackgroundMethodModeling and Analysis of Modular Multilevel Converter in DC Voltage Control Timescale
Hu, J., Zhu, J., & Wan, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2875640 · Cited by 44
“Another method is the impedance modeling in the frequency domain based on multiharmonic linearization as reported in [14] and [15], which considers the internal dynamics and compares the characteristics of two different modulation strategies.”
BackgroundMethodSegundo‐Ramírez, J., Bayo-Salas, A., Esparza, M., Beerten, J., & Gómez, P. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2927171 · Cited by 42
“harmonic stability for distribution networks [59], [60], offshore wind farms [53], [61], [62], HVDC converters embedded in an AC system [63]–[65], and HVDC links [66]–[69].”
BackgroundGeneralized Impedance Analysis and New Sight at Damping Controls for Wind Farm Connected MMC–HVdc
Ji, K., Liu, S., Pang, H., Yang, J., Xu, Z., He, Z., & Tang, G. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3017896 · Cited by 40
Kolluri, S., Gorla, N. B. Y., Sapkota, R., & Panda, S. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2897150 · Cited by 41
Chen, G., Hao, P., Zeng, R., Hu, Y., & Ni, K. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2764684 · Cited by 40
“For example, for a MMC system with 20 SMs in each arm, if Y = 8, then the charging ability of driving pulses 1–20 in ascending order is [8, 7, 9, 6, 10, 5, 11, 4, 12, 3, 13, 2, 14, 1, 15, 20, 16, 19, 17, 18].”
Lu, X., Xiang, W., Lin, W., & Wen, J. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.01.046 · Cited by 38
Kolluri, S., Gorla, N. B. Y., & Panda, S. K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2971737 · Cited by 39
“2971737 applications such as high-voltage direct current (HVdc) transmission systems [1]–[3], flexible alternating current transmission system (FACTS) controllers, offshore renewable energy integration [4], [5], and medium-voltage motor drives [6]–[8].”
BackgroundGrey box aggregation modeling of wind farm for wideband oscillations analysis
Zong, H., Lyu, J., Wang, X., Zhang, C., Zhang, R., & Cai, X. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.116035 · Cited by 37
Self-citationMMC Impedance Modeling and Interaction of Converters in Close Proximity
Chen, Y., Xu, L., Egea‐Àlvarez, A., Marshall, B., Rahman, H., & Adeuyi, O. D. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3031489 · Cited by 36
“In [9], an analytical sequence impedance model of a three-phase MMC is derived with the internal MMC dynamics, following the same approach used for 2-level VSCs.”
MethodRevisit Impedance-Based Stability Analysis of VSC-HVDC System
Tan, Y. R., Sun, Y., Lin, J., Yuan, L., & Su, M. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3234145 · Cited by 35
“In a VSC-HVDC system, abundant dynamic interactions exist between VSCs and AC networks, or VSCs and DC networks, which might result in instability [4], [5].”
BackgroundZou, X., Du, X., & Tai, H. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2918279 · Cited by 34
“The overall wind turbine grid-connected system can be simplified to an inverter-grid system when the dynamics of the MSC and the dc-bus dynamics for the D-PMSG-based wind turbine are ignored [28], [29].”
BackgroundImpedance Profile Prediction for Grid-Connected VSCs With Data-Driven Feature Extraction
Wu, Y., Wu, H., Li, C., Zhou, J., Zhou, Z., Chen, M., & Wang, X. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3495214 · Cited by 33
“Nowadays,theimpedance-basedstabilityanalysisiswidely appliedintheindustry[7],[8],[9],[10],whichreliesonthe converterimpedanceprofiles.”
Magnetic Integration of LTL Filter With Two LC-Traps for Grid-Connected Power Converters
Li, X., Lin, P., & Tang, Y. K. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2764060 · Cited by 33
Impedance-based analysis of harmonic instabilities in HVDC-connected Offshore Wind Power Plants
Cheah-Mañé, M., Sainz, L., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.10.031 · Cited by 40
“circulating current control or energy control, also have a slow dynamic response with interactions below the synchronous frequency [10, 20]”
BackgroundMethodResultInfluentialStudy of resonance issues between DFIG-based offshore wind farm and HVDC transmission
Zhang, Y. G., Klabunde, C., & Wolter, M. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106767 · Cited by 33
“Generally, Nyquist and Bode-plot methods are applied to study resonances at the point of common coupling (PCC), which requires equalizing a system into load and source subsystems [14], [15].”
BackgroundMethodEnhanced AC voltage and frequency control of offshore MMC station for wind farm connection
Jing, Y., Li, R., Xu, L., & Wang, Y. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.5391 · Cited by 32
“In [15], offshore grid three-phase voltages are added to the output of the PR controllers as feed-forwards to improve the dynamics of the offshore voltage controller.”
BackgroundImpedance-Based Prediction of Distortions Generated by Resonance in Grid-Connected Converters
Shah, S., & Parsa, L. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2904674 · Cited by 32
“The small-signal impedance-based analysis is used for evaluating stability of wind farms and HVDC transmission networks [9], [16].”
MethodShao, B., Zhao, S., Gao, B., Yang, Y., & Blaabjerg, F. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106498 · Cited by 30
Energy dissipation of MMC‐HVDC based onshore wind power integration system with FB‐DBS and DCCB
Cao, S., Xiang, W., Lu, X., Lin, W., Zhang, K., Wen, J., & Zhang, X. (2019) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2019.0491 · Cited by 29
A Method for the Calculation of the AC-Side Admittance of a Modular Multilevel Converter
Bessegato, L., Harnefors, L., Ilves, K., & Norrga, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2862254 · Cited by 30
“Reference [22] presents a model of the MMC impedance; however, the submodule capacitor-voltages are treated as constant, effectively modeling the MMC as a two-level VSC.”
MethodKumar, D., Shireen, W., & Ram, N. (2024) · Energies · doi:10.3390/en17215308 · Cited by 28
Impedance-based and eigenvalue based stability assessment compared in VSC-HVDC system
Amin, M., Rygg, A., & Molinas, M. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855185 · Cited by 28
Self-citationImpedance Modeling of Modular Multilevel Converter in D-Q and Modified Sequence Domains
Zhu, S., Qin, L., Liu, K., Ji, K., Li, Y., Huai, Q., Liao, X., & Yang, S. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3028079 · Cited by 34
Study on the Method for Analyzing Electric Network Resonance Stability
Xu, Z. G., Wang, S., Xing, F., & Xiao, H. (2018) · Energies · doi:10.3390/en11030646 · Cited by 27
“Oscillations in the scenario of wind farm integration through a modular multilevel converter-based HVDC (MMC-HVDC) have also been reported [6,7].”
BackgroundHu, Y., Bu, S., Zhou, B., Liu, Y., & Fei, C. (2019) · IEEE Access · doi:10.1109/access.2019.2937395 · Cited by 26
“As reported in [80] and [81], the MMC contains many sub-modules (SMs) with complex internal dynamics and”
BackgroundYang, J., Guenter, S., Buticchi, G., Gu, C., Liserre, M., & Wheeler, P. W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3270531 · Cited by 28
“The impedance-based stability analyses of MMC-based systems have been given in [27], [28], [29].”
MethodWang, H., Yang, S., Chen, H., Feng, X., & Blaabjerg, F. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2993284 · Cited by 27
“Various schemes have been proposed for MMC system stability analysis [29, 30], the frequency domain analysis utilizing control loop transfer function is adopted in the paper.”
MethodYin, T., Wang, Y., Yue, B., Xu, P., Li, P., Mei, N., & Xu, D. (2020) · IEEE Access · doi:10.1109/access.2020.3014248 · Cited by 26
Distributed stabilizing modular control for stand-alone microgrids
Makrygiorgou, D. I., & Alexandridis, A. T. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.07.085 · Cited by 25
Impedance Modeling and Stability Analysis of DFIG Wind Farm With LCC-HVDC Transmission
Wang, M., Chen, Y., Dong, X., Hu, S., Liu, B., Yu, S. S., Ma, H., Zhang, X., & Liu, X. (2022) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2022.3144999 · Cited by 25
Power system wideband oscillation estimation, localization, and mitigation
An, S., Qiu, W., Pu, Q., Chen, S., Zheng, Y., Duan, J., Huang, Q., & Yao, W. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12845 · Cited by 25
Zheng, W., Hu, J., & Yuan, X. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2923282 · Cited by 24
“Interactions between HVDC and wind farms are analyzed in [10], [11], so the dynamics of DC voltage are neglected.”
BackgroundStability and control of VSC-based HVDC systems: A systematic review
Mohammadi, F., Azizi, N., Moradi, H., & Rouzbehi, K. (2024) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2024.100503 · Cited by 26
Impedance Modeling and Stability Analysis of Energy Controlled Modular Multilevel Converter
Lyu, J., Yin, J., Zhu, H., & Cai, X. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3225640 · Cited by 23
“3225640 used in analyzing the small-signal stability of the MMC connected systems [4], [5], [6], due to its advantages such as clear physical meaning, simple modeling, easy measurement, and so on.”
BackgroundSelf-citationLin, H., Xue, T., Lyu, J., & Cai, X. (2023) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000363 · Cited by 23
“Modular multilevel converter based high-voltage direct current (MMC-HVDC) has become the prevailed scheme for remote offshore wind farms [4], [5].”
BackgroundSelf-citationZhu, S., Liu, K., Le, J., Ji, K., Huai, Q., Wang, F., & Liao, X. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3142751 · Cited by 22
“3142751 wind farms and MMC-based DC transmission systems [1], [2].”
BackgroundModeling and Harmonic Stability of MMC-HVDC With Passive Circulating Current Filters
Zhang, B., & Nademi, H. (2020) · IEEE Access · doi:10.1109/access.2020.3009331 · Cited by 22
“The harmonic stability discussed here focuses on static stability, which is also called ‘‘small-signal’’ stability [20], [25], ‘‘impedance-based’’ stability with passive R-L load [21], ‘‘frequency-domain’’ stability [26] and harmonic stability [24], [27].”
He, Z., Hu, J., Lin, L., & Zeng, P. (2021) · High Voltage · doi:10.1049/hve2.12144 · Cited by 23
Sun, Y., Zhang, Z., Zhang, Y., Li, Y., & Li, Z. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3137411 · Cited by 21
Harmonic State Space Modeling and Analysis of Modular Multilevel Converter
Lyu, J., Cai, X., Zhang, X., & Molinas, M. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590305 · Cited by 21
Self-citationA Novel Electrolytic Capacitor-Less MMC With Magnetic Power Decoupling Method
Irfan, M. S., Tawfik, M. A., Ahmed, A., & Park, J. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2997983 · Cited by 21
Impedance modeling of modular multilevel converters by harmonic linearization
Lyu, J., Chen, Q., & Cai, X. (2016) · 2016 IEEE 17th Workshop on Control and Modeling for Power Electronics (COMPEL) · doi:10.1109/compel.2016.7556719 · Cited by 20
“The analytical ac-side impedance models of an MMC were derived for the impedance-based stability analysis of MMC-HVDC systems with wind farms in [8], but the capacitor voltage ripples were ignored in the procedure of small-signal linearization.”
MethodSelf-citationGrid-Forming Droop Control of a Modular Multilevel Converter in Laboratory
Henninger, S., Schroeder, M., & Jaeger, J. (2018) · 2018 IEEE Power & Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2018.8586205 · Cited by 20
“The focus is instantaneous active power support and parallel operation of the grid-forming MMC with other voltage sources, whereas in [7] the MMC is operating as the only voltage source.”
BackgroundFPGA-Based Implementation of MMC Control Based on Sorting Networks
Ricco, M., Máthé, L., Monmasson, É., & Teodorescu, R. (2018) · Energies · doi:10.3390/en11092394 · Cited by 20
“Energies 2018, 11, x FOR PEER REVIEW 3 of 18 phase HVDC grid connected MMC application with half-bridge SM is consi ered (Figure 1).”
BackgroundInfluentialChai, N., Tian, W., Gao, X., Rodríguez, J., Heldwein, M. L., & Kennel, R. M. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3170503 · Cited by 19
“It has been widely used in high-voltage direct current (HVDC) transmission systems [4], medium-voltage motor drive applications [5], static synchronous compensator (STACOM) [6], and so on.”
MethodMitigating SSO in an Actual DFIG-MTDC System: Field Implementation and Tests
Li, H., Xie, X., Shair, J., Liu, R., & Xu, J. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3285272 · Cited by 19
“Subsynchronous oscillation(SSO)indoublyfedinductiongenerator(DFIG)-basedwind farmsconnectedtoMMC-HVDChasarousedwidespreadcon-cerninbothacademiaandindustry[5],[6],[7],[8].”
Gao, B., Liu, Y., Shao, B., & Ran, H. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108328 · Cited by 18
Impedance modeling of modular multilevel converter based on harmonic state space
Chen, Q., Lyu, J., Li, R., & Cai, X. (2016) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2016.7556721 · Cited by 21
“Ac terminal impedance of MMC, under different modulation methods and circulating current control schemes, has been given in [4], [5].”
MethodSelf-citationControl Strategy Optimization of Voltage Source Converter Connected to Various Types of AC Systems
Liu, Z., & Guo, X. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2020.000352 · Cited by 18
A Capacitor Voltage Balancing Approach Based on Mapping Strategy for MMC Applications
Ricco, M., Máthé, L., Hammami, M., Franco, F. L., Rossi, C., & Teodorescu, R. (2019) · Electronics · doi:10.3390/electronics8040449 · Cited by 18
“For these reasons, this topology is widely adopted in applications such as: High Voltage Direct Current (HVDC) [1], Static Compensators (STATCOM) [2] and in high-power motor drivers [3].”
MethodValikhany, M., Astero, P., Lehtonen, M., & Peltoniemi, P. (2025) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2025.101131 · Cited by 17
Stability Analysis of Wind Farm Connected to Hybrid HVDC Converter
Li, J., Wang, X., Lyu, J., Zong, H., Xue, T., Fang, Z., & Cai, X. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367833 · Cited by 17
“The stability analysis and control of wind farm connected with full-power MMC-based HVDC converter has been discussed a lot [3], [8]-[11].”
BackgroundSelf-citationSun, Y., Zhang, Z., Wang, Y., Li, Z., & Rodríguez, J. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3125036 · Cited by 16
Impedance Modeling and Stability Analysis in Co-Phase Traction Power Supply System
Liu, F., Ma, L., Zhou, F., Cheng, S., & Xiong, J. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3355141 · Cited by 16
Metadata
- Authors
- Lyu, J., Cai, X., & Molinas, M.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Norwegian University of Science and Technology (NO)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2016-03
- Volume
- 4
- Issue
- 1
- Pages
- 141-151
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2260664280
- Cited by
- 267
- References
- 29
- Citations by year
- 2026: 14 · 2025: 23 · 2024: 24 · 2023: 30 · 2022: 20 · 2021: 25 · 2020: 38 · 2019: 23 · 2018: 33 · 2017: 31 · 2016: 6
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- BIBSYS Brage (BIBSYS (Norway)) (acceptedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- National High Technology Research and Development Program of China (863 Program) (2013AA050601)
- Shanghai Science and Technology Committee Fund (13dz1200202)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- modular multilevel converter, HVDC transmission, offshore wind farm integration, frequency-domain stability analysis, impedance-based stability, phase margin, resonance, circulating current control, direct modulation, Nyquist plot
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.