Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This paper investigates the stability of offshore wind farms integration through a modular multilevel converter-based high-voltage dc (MMC-HVdc) transmission system. Resonances or instability phenomena have been reported in between wind farms and MMC-HVdc systems. They are arguably originated due to interactions between the MMC and the wind power inverters. However, the nature of these interactions is neither well understood nor reported in the literature. In this paper, the impedance-based analytical approach is applied to analyze the stability and to predict the phase margin of the interconnected system. For that, analytical impedance models of a three-phase MMC in a compensated modulation case and a direct modulation case are separately derived using the small-signal frequency domain method. Moreover, the impedance models of the MMC take the circulating current control into account. The derived impedance models are then verified by comparing the frequency responses of the analytical model with the impedance measured in a nonlinear time-domain simulation model developed in MATLAB. The results show that the potential resonances or instability of the interconnected system can be readily predicted through the Nyquist diagrams. In addition, the analysis indicates that the circulating current control of the MMC has a significant impact on the stability of the interconnected system. Finally, the time-domain simulations validate the theoretical analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346 · cited 1×
“AMODULAR multilevel converter-based high-voltage dc (MMC-HVdc) transmission technology has become a promising solution for the grid integration of large-scale offshore wind farms, due to its advantages, such as modular design, high efficiency, low distortion of output voltage, easily scalable in terms of voltage level…”
BackgroundAnalysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334 · cited 1×
“The d–q impedances of two-level grid-connected inverters with feedback control and PLL were derived and measured in [20]–[22], and an impedance-based stability analysis for three-phase gridconnected paralleled converters was performed in [22].”
MethodDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“AMODULAR multilevel converter-based high-voltage dc (MMC-HVdc) transmission technology has become a promising solution for the grid integration of large-scale offshore wind farms, due to its advantages, such as modular design, high efficiency, low distortion of output voltage, easily scalable in terms of voltage level…”
BackgroundImpedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167 · cited 3×
“VSCs have been well investigated in [19], so the results of the paper have been used for the impedance modeling of the wind power inverter in this paper.”
BackgroundMethodInput-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117 · cited 1×
“Most research has so far focused on the impedance modeling of two-level converters [18]–[26].”
BackgroundModeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785 · cited 2×
“Moreover, the Nyquist map is also able to demonstrate the impact of system parameters on stability, which has a great significance in designing a power electronics-based system [17].”
BackgroundMethodSmall-Signal Methods for AC Distributed Power Systems–A Review
Sun, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029859 · Cited by 712 · cited 1×
“of the d–q impedance-based stability analysis is that it can only detect whether the system is stable or not, but cannot determine the stability margin [27].”
BackgroundDynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 5×
“, v d = vdu −vdl, for a three-phase MMC, v d = 0 [4].”
BackgroundMethodInfluentialImpedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586 · cited 1×
“The d–q impedances of two-level grid-connected inverters with feedback control and PLL were derived and measured in [20]–[22], and an impedance-based stability analysis for three-phase gridconnected paralleled converters was performed in [22].”
MethodIlves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2378731 · Cited by 453
Hybrid Design of Modular Multilevel Converters for HVDC Systems Based on Various Submodule Circuits
Qin, J., Saeedifard, M., Rockhill, A., & Zhou, R. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2351794 · Cited by 358
Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network
Miao, Z. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2012.2211019 · Cited by 329 · cited 1×
“In [10], subsynchronous resonance (SSR) in DFIG-based wind farms, resulting from the interaction between the converter control and the series-compensated line, was studied and the impacts of wind speed, compensation level, and current controller gain on SSR were then examined.”
BackgroundBergna, G., Berne, E., Egrot, P., Lefranc, P., Arzande, A., Vannier, J.-C., & Molinas, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2225397 · Cited by 267 · cited 1×
“, internal circulating current [5], submodule (SM) capacitor voltage balancing [6], and so on, which have a large influence on the operation stability of the interconnected system.”
BackgroundSelf-citationHuang, J., Corzine, K. A., & Belkhayat, M. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2007212 · Cited by 253 · cited 1×
“Furthermore, some methods for measuring the d–q impedances through impedance measurement circuits were proposed in [25] and [26].”
MethodVoltage Stability and Control of Offshore Wind Farms With AC Collection and HVDC Transmission
Liu, H., & Sun, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2361290 · Cited by 245 · cited 3×
“in [12], in which, however, the VSC-HVdc system is based on two-level converters that lack of internal dynamics, so the instability mechanism would not be able to correctly interpret the SSO phenomenon in the MMC-HVdc system with wind”
BackgroundMethodResonance Issues and Damping Techniques for Grid-Connected Inverters With Long Transmission Cable
Zhang, S., Jiang, S., Lu, X., Ge, B., & Peng, F. Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2253127 · Cited by 218 · cited 1×
“In [9], the high-frequency resonance issues in offshore wind farms caused by the distributed inductance and capacitance of the long-distance high-voltage ac transmission cable were investigated, and a cascaded notch-filter-based active damping method was also proposed to eliminate the resonant peaks.”
BackgroundImpedance-Based Stability and Transient-Performance Assessment Applying Maximum Peak Criteria
Vesti, S., Suntio, T., Oliver, J. A., Prieto, R., & Cobos, J. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2220157 · Cited by 180
An algorithm and implementation system for measuring impedance in the D-Q domain
Francis, G., Burgos, R., Boroyevich, D., Wang, F., & Karimi, K. (2011) · 2011 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2011.6064203 · Cited by 158 · cited 2×
“Furthermore, some methods for measuring the d–q impedances through impedance measurement circuits were proposed in [25] and [26].”
BackgroundMethodLiu, Z., Liu, J., Bao, W., & Zhao, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331419 · Cited by 149
DC Impedance-Model-Based Resonance Analysis of a VSC–HVDC System
Xu, L., Fan, L., & Miao, Z. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2367123 · Cited by 123 · cited 1×
“The ac- and dc-side d–q impedances of a two-level VSC-HVdc transmission system with the outer and inner control loops were derived, respectively, and then the ac- and dc-side resonances of the VSC-HVdc system were examined using the impedance-based Nyquist stability criterion in [23] and [24].”
MethodImpedance-Based Resonance Analysis in a VSC-HVDC System
Xu, L., & Fan, L. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2272382 · Cited by 111 · cited 1×
“The ac- and dc-side d–q impedances of a two-level VSC-HVdc transmission system with the outer and inner control loops were derived, respectively, and then the ac- and dc-side resonances of the VSC-HVdc system were examined using the impedance-based Nyquist stability criterion in [23] and [24].”
MethodWind turbine converter control interaction with complex wind farm systems
Kocewiak, Ł., Hjerrild, J., & Bak, C. L. (2013) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2012.0209 · Cited by 79 · cited 1×
“In addition, the interaction between the wind turbine control system and the wind farm structure was also investigated in [11].”
BackgroundHarmonics and resonance issues in wind power plants
Bradt, M., Badrzadeh, B., Camm, E. H., Mueller, D., Schoene, J., Siebert, T., Smith, T., Starke, M. R., & Walling, R. A. (2011) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2011.6039398 · Cited by 74
An impedance-based stability analysis method for paralleled voltage source converters
Wang, X., Blaabjerg, F., & Loh, P. C. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6869788 · Cited by 60
Subsynchronous oscillation of large DFIG-based wind farms integration through MMC-based HVDC
Lv, J., Dong, P., Shi, G., Cai, X., Rao, H., & Chen, J. (2014) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2014.6993945 · Cited by 51 · cited 1×
“A subsynchronous oscillation (SSO) phenomenon in an MMC-HVdc system with doubly-fed induction generator (DFIG)-based wind farms has been reported in [7], in which the distribution and propagation mechanisms of the output SSO current from wind farms in an MMC-HVdc system were revealed and an SSO current suppression sch…”
MethodSelf-citationShi, X., Wang, Z., Liu, B., Li, Y., Tolbert, L. M., & Wang, F. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954133 · Cited by 33 · cited 2×
“According to the continuous model of the MMC [4], [28], one can obtain { vk cu = nuv ∑ k cu”
Method
Cited by
Lyu, J., Zhang, X., Cai, X., & Molinas, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2842682 · Cited by 345
Self-citationModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“[40] and [41] are two of the first attempts to develop impedance models of three-phase MMCs valid for power system stability studies.”
BackgroundSequence Impedance Modeling of Modular Multilevel Converters
Sun, J., & Liu, H. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2762408 · Cited by 287
“Reference [14] reported MMC impedance models and HVDC system analysis using the methods described in [7], [10], and [12].”
BackgroundMethodLyu, J., Cai, X., & Molinas, M. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2759096 · Cited by 194
“Moreover, the internal dynamics of MMC such as capacitor voltage fluctuations and harmonic circulating currents may have harmful effects on the stable operation of MMC-based interconnected systems, especially for renewable energy integration applications [5], [6].”
BackgroundMethodSelf-citationSub‐synchronous oscillation mechanism and its suppression in MMC‐based HVDC connected wind farms
Lyu, J., Cai, X., Amin, M., & Molinas, M. (2017) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2017.1066 · Cited by 138
Self-citation
Metadata
- Authors
- Lyu, J., Cai, X., & Molinas, M.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Norwegian University of Science and Technology (NO)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2016-03
- Volume
- 4
- Issue
- 1
- Pages
- 141-151
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2260664280
- Cited by
- 267
- References
- 29
- Citations by year
- 2026: 14 · 2025: 23 · 2024: 24 · 2023: 30 · 2022: 20 · 2021: 25 · 2020: 38 · 2019: 23 · 2018: 33 · 2017: 31 · 2016: 6
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- BIBSYS Brage (BIBSYS (Norway)) (acceptedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- National High Technology Research and Development Program of China (863 Program) (2013AA050601)
- Shanghai Science and Technology Committee Fund (13dz1200202)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- modular multilevel converter, HVDC transmission, offshore wind farm integration, frequency-domain stability analysis, impedance-based stability, phase margin, resonance, circulating current control, direct modulation, Nyquist plot
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.