Design and Implementation of a Modular Multilevel Converter With Hierarchical Redundancy Ability for Electric Ship MVDC System
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Modular multilevel converter (MMC) can be considered as a promising candidate for modern electric ship medium-voltage direct current (MVDC) power system due to its high-voltage quality, low switching loss, good expansibility, and good redundancy. As the voltage level in MVDC is much lower than that in high-voltage direct current case, the number of submodules (SMs) of MMC in MVDC system is also much less. Therefore, the SM failure will have more significant effect on the safety operation. Since uninterrupted operation is one of the most important requirements in electric ship application, the special redundancy design for MMC is required. This paper thus proposes an MMC system with hierarchical redundancy ability, aiming to guarantee the ride-through operation under SM failure. The “hot-reserved” and “cold-reserved” SMs are prepared in the MMC by compromising the faulty SM number, voltage and current stress of SMs, SM power loss, and so on, and the hierarchical redundancy strategy is divided into several progressive layers to ride through the SM failure in different cases. The pretreatment units are designed to realize the proposed hierarchical redundant strategy smoothly, and without changing the existent modulation and sort-and-selection strategies designed for normal condition. The proposed design is explained in this paper, and verified by a three-phase MMC simulation and a single-phase MMC prototype.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multicarrier PWM strategies for multilevel inverters
McGrath, B. P., & Holmes, D. G. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801073 · Cited by 1,232 · cited 1×
“on the method [35], aiming to generate the proper SM number signal nL that needs to be driven by “1”; however, its rule has been extended to adapt to the redundancy purpose.”
MethodFault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“battery [4], [16], [17], the MMC can obtain the energy storage ability; and if the active power filter is added to”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329 · cited 1×
“In [18] and [19], SM fault is detected by sliding mode observer.”
BackgroundSon, G. T., Lee, H.-J., Nam, T. S., Chung, Y.-H., Lee, U.-H., Baek, S.-T., Hur, K., & Park, J.-W. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2190530 · Cited by 290 · cited 3×
“In [23]–[26], the “hot-reserved” and “cold-reserved” SMs were prepared.”
BackgroundOperation of a Medium-Voltage Drive Under Faulty Conditions
Rodriguez, J., Hammond, P. W., Pontt, J., Musalem, R., Lezana, P., & Escobar, M. J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
Fault Detection and Localization Method for Modular Multilevel Converters
Deng, F., Chen, Z., Khan, M. R., & Zhu, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2348194 · Cited by 266 · cited 1×
“battery [4], [16], [17], the MMC can obtain the energy storage ability; and if the active power filter is added to”
BackgroundModular multilevel inverter: pulse width modulation and capacitor balancing technique
Adam, G. P., Anaya-Lara, O., Burt, G. M., Telford, D., Williams, B. W., & McDonald, J. R. (2010) · IET Power Electronics · doi:10.1049/iet-pel.2009.0184 · Cited by 248
Shao, S., Watson, A. J., Clare, J. C., & Wheeler, P. W. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2462717 · Cited by 182 · cited 1×
“Reference [20] employed a Kalman filter to detect the fault.”
MethodEnhancing the reliability of modular medium-voltage drives
Hammond, P. W. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803172 · Cited by 176 · cited 1×
“In [23]–[26], the “hot-reserved” and “cold-reserved” SMs were prepared.”
Energy-balancing Control Strategy for Modular Multilevel Converters Under Submodule Fault Conditions
Hu, P., Jiang, D., Zhou, Y., Liang, Y., Guo, J., & Lin, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284919 · Cited by 148 · cited 1×
“Besides, the output port of the SM is associated with a mechanical switch Q [23], [30], [31], and it can be turned ON or OFF for redundancy purpose.”
Background
Cited by
Modular Multilevel Converters for Transportation Electrification: Challenges and Opportunities
Ronanki, D., & Williamson, S. S. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2792330 · Cited by 345
“Recently, the MMC has gained attention in the field of transportation due to aforementioned features and become promising for electric railway traction [13], [14], railway power supplies [15], [16], battery energy storage systems (ESSs) [17], [18], emerging electric ship [19], [20], battery charging infrastructure [21…”
BackgroundInfluentialModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“Designing the on-board converter with redundant submodules, the converter reliability is improved [153].”
BackgroundReliability and Cost based Redundancy Design for Modular Multilevel Converter
Tu, P., Yang, S., & Wang, P. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793263 · Cited by 199
Recent Advancements in Submodule Topologies and Applications of MMC
Ali, S., Ling, Z., Tian, K., & Huang, Z. M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2990689 · Cited by 119
“The MV-dc shipboard systems are better than the ac system because they offer good power quality, high transmission ability, integration of RES, and high efficiency by removing energy conversion devices [233]–[235].”
BackgroundA New Single-Phase Five-Level Inverter Topology for Single and Multiple Switches Fault Tolerance
Aly, M., Ahmed, E. M., & Shoyama, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2792146 · Cited by 111
“Another solution is to add an extra module in each leg of the modular multilevel inverters [17], [18].”
BackgroundRonanki, D., & Williamson, S. S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2884610 · Cited by 106
“The CHB topology requires independent dc sources which will increase the overall cost of the system [6], [9].”
BackgroundActive Power Decoupling for Submodules of a Modular Multilevel Converter
Kong, Z., Huang, X., Wang, Z., Xiong, J., & Zhang, K. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2661539 · Cited by 95
Ronanki, D., & Williamson, S. S. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2912771 · Cited by 88
“2912771 construction and easy assembling, MMCs draw considerable attention to electric ship propulsion systems [3], [4], battery electric vehicles [5], electric railway traction systems [6], rail-”
BackgroundA Review of Power Converters for Ships Electrification
Mahdi, H., Hoff, B., & Østrem, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3227398 · Cited by 79
“MMC can be used in dc–ac [81] or ac–dc [87] power stage for electric ship, as illustrated in Fig.”
BackgroundMethodA review of power electronics equipment for all-electric ship MVDC power systems
Castellan, S., Menis, R., Tessarolo, A., Luise, F., & Mazzuca, T. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.09.040 · Cited by 86
“A fault-tolerant MMC DC/AC VSC for shipboard MVDC applications is proposed, simulated and experimentally tested in [99].”
MethodZheng, G., Chen, Y., & Kang, Y. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3013493 · Cited by 74
“Referring to [30]–[32], the grid filter inductor L1 is set as 10 mH.”
Self-citationAn Overview of Applications of the Modular Multilevel Matrix Converter
Díaz, M., Cárdenas, R., Ibaceta, E., Mora, A., Urrutia-Ortiz, M., Espinoza, M., Rojas, F., & Wheeler, P. W. (2020) · Energies · doi:10.3390/en13215546 · Cited by 71
“Additionally, some publications suggest to provide some level of redundancy in the converter [70].”
BackgroundBarros, L. A. M., Martins, A., & Pinto, J. G. O. (2022) · Energies · doi:10.3390/en15031078 · Cited by 80
Cui, S., Lee, H.-J., Jung, J.-J., Lee, Y., & Sul, S. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797934 · Cited by 69
A Hybrid Modular Multilevel Converter Family With Higher Power Density and Efficiency
Liu, J., Dong, D., & Zhang, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3055690 · Cited by 60
“Therefore, MEMC shows great potential in some applications which are sensitive to the converter size and power density, such as offshore windfarm and emerging electric ship tractions [31].”
BackgroundLi, B., Xu, Z., Ding, J., & Xu, D. (2018) · IEEE Access · doi:10.1109/access.2018.2811904 · Cited by 57
“In references [21]– [23], the redundant SMs are configured in cold reserve mode, in which these SMs are normally bypassed by a contactor and only activated when fault happens.”
BackgroundKou, L., Liu, C., Cai, G. W., & Zhang, Z. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106370 · Cited by 64
“Among them, the model-based method is difficult to realize because the fault mathematical model is difficult to establish [11,12].”
MethodKurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2763 · Cited by 57
Wang, J., & Tang, Y. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890536 · Cited by 54
“Therefore, the cold reserve mode is more suitable for MMCs in high voltage applications with hundreds of SMs, in which the conduction losses are usually more important than the SM utilization ratio [12]–[14].”
BackgroundChappa, A., Gupta, S., Sahu, L. K., & Gupta, K. K. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2994880 · Cited by 51
Wang, Z., & Li, P. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011131 · Cited by 54
“The diode fault is ignored here due to its low probability of occurrence, such as most research works and applications [27]–[29].”
BackgroundModular Multilevel Converter With Three-Port Power Channels for Medium-Voltage Drives
Huang, X., Wang, Z., Kong, Z., Xiong, J., & Zhang, K. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2770162 · Cited by 43
“, in the electric ship where the MVDC system is adopted [6].”
BackgroundLiu, S., Guo, X., & Zhang, L. (2019) · Energies · doi:10.3390/en12163162 · Cited by 45
“By integrating propulsion power with the consumption of other electricity, this compact structure is characterized by its reduced volumes of power units and enhanced operation reliability, together with unified energy utilization and management [1,2].”
BackgroundA New Voltage Measure Method for MMC Based on Sample Delay Compensation
Rong, F., Gong, X., Li, X., & Huang, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2748969 · Cited by 39
Ronanki, D., & Williamson, S. S. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3009078 · Cited by 39
“MMCs are also gaining notable attention in medium-voltage system applications, such as static synchronous compensators [5], energy storage systems [6], motor drives [7], ship propulsion systems [8], shipboard power conversion units [9], railway power conditioners [10], and green energy technologies [11], [12].”
BackgroundChakraborty, R., & Dey, A. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3021641 · Cited by 39
“8 kV operating voltage and use 3–15 SMs per arm [33], [35].”
BackgroundHong, L., Xu, Q., He, Z., Ma, F., Luo, A., & Guerrero, J. M. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2879981 · Cited by 37
“The MMC applied for medium voltage applications usually require 4 to 10 basic SMs in each arm [18].”
BackgroundXiao, Q., Wang, J., Jin, Y., Chen, L., Jia, H., Dragičević, T., & Teodorescu, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2967576 · Cited by 38
“The cold reserve-based fault-tolerant methods, where reserve SMs are usually bypassed and inserted only when SM faults occur, are adopted in high-voltage high-power applications [12].”
BackgroundHassani, M. J., Azimi, E., Khodaparast, A., Adabi, J., & Pouresmaeil, E. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3135623 · Cited by 33
Hu, J., He, Z., Lin, L., Xu, K., & Qiu, Y. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2820076 · Cited by 32
“2820076 excellent quality of waveform [4]–[8].”
A Survey on the State-of-the-Art and Future Trends of Multilevel Inverters in BEVs
Hren, A., Truntič, M., & MIHALIC, F. (2023) · Electronics · doi:10.3390/electronics12132993 · Cited by 32
Ronanki, D., & Williamson, S. S. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.6362 · Cited by 29
Farzamkia, S., Rizi, H. S., Huang, A. Q., & Iman‐Eini, H. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3181416 · Cited by 28
Fahad, M., Tariq, M., Sarwar, A., Modabbir, M., Zaid, M. A., Satpathi, K., Hussan, M. R., Tayyab, M., Alamri, B. R., & Alahmadi, A. A. (2021) · Energies · doi:10.3390/en14144302 · Cited by 28
“Adding extra legs to individual modules for modular multilevel converter (MMC) topologies is investigated in [15], with similar consequences of increased switch count and complexity.”
BackgroundLast Developments and New Technologies in Solid-State Transformer
Liserre, M., Costa, L. F., Guo, Z., D’Amato, D., Queiroz, S. S., & Huang, A. Q. (2024) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg61800.2024.10667423 · Cited by 29
Investigation on Fault Tolerant Capability of a Single Source Switched Capacitor Multilevel Inverter
Bikdeli, E., Adabi, J., Rezanejad, M., & Gholamian, S. A. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3016270 · Cited by 28
“mance of modular multilevel converters during fault occurrence [17], [18].”
BackgroundChappa, A., Gupta, S., Sahu, L. K., Gupta, K. K., & Vahedi, H. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3102480 · Cited by 27
DC/DC Modular Multilevel Converters for HVDC Interconnection: A Comprehensive Review
Erat, A., & Vural, A. M. (2022) · International Transactions on Electrical Energy Systems · doi:10.1155/2022/2687243 · Cited by 27
“Due to significant characteristics, the MMC has recently attracted attention in the field of transportation and emerged as a promising candidate for HVDC transmission systems [13, 16, 17], electric railway traction [18, 19], railway power supplies [20, 21], static synchronous compensator (STATCOM) [22, 23], battery en…”
BackgroundOn Inherent Redundancy of MMC-Based STATCOMs in the Overmodulation Region
Cupertino, A. F., Pereira, H. A., Seleme, S. I., & Teodorescu, R. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2936784 · Cited by 25
“Under such conditions, if one failure occurs, the faulty cell can be replaced by a redundant cell and the converter remains operating [5], [6].”
BackgroundModeling and Control Method for a Three-Level Hybrid Modular Multilevel Converter
Liu, J., Zhang, D., & Dong, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3118425 · Cited by 24
“Therefore, it shows great potential in applications which are sensitive to the converter size and power density, such as offshore wind farm, emerging electric ship tractions and city in-feed [25].”
BackgroundSingle-Phase Five-Level Multiswitch Fault-Tolerant Inverter
K, V. S. P., & Peddapati, S. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3259722 · Cited by 22
“The other type of MLI topologies, such as modular MLIs [28], [29], incorporates the FT features by using redundant submodules.”
BackgroundSharifi, S., Ferencz, I., Kamel, T., Petreuș, D. M., & Tricoli, P. (2022) · IET Electrical Systems in Transportation · doi:10.1049/els2.12054 · Cited by 24
Power Losses of Advanced MMC Submodule Topologies Using Si- and SiC-Semiconductors
Dahmen, C., & Marquardt, R. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915430 · Cited by 20
Ning, G., & Chen, W. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2801783 · Cited by 19
“advantages such as high efficiency, light system weight, high controllability, and no reactive power [4], [5].”
Background11kW, 70kHz LLC Converter Design with Adaptive Input Voltage for 98% Efficiency in an MMC
Unruh, R., Schafmeister, F., & Böcker, J. (2020) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel49091.2020.9265771 · Cited by 17
“This reserve is selected to cover grid overvoltages of 10 % and one possible damaged module in each arm [18].”
BackgroundNew Submodule Topology Based Fault Tolerance for Modular Multilevel Converters
Geng, Z., Han, M., Bao, W., & Xie, W. (2023) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2023.3237891 · Cited by 16
“In [20], [21], the charging strategies are designed for the CRSMs.”
BackgroundKurtoğlu, M., & Vural, A. M. (2022) · International Transactions on Electrical Energy Systems · doi:10.1155/2022/2169357 · Cited by 19
Weighted Bandwidth Method for Stability Assessment of Complex DC Power Systems on Ships
Bosich, D., Giadrossi, G., Pastore, S., & Sulligoi, G. (2021) · Energies · doi:10.3390/en15010258 · Cited by 14
A ZVZCS Full-Bridge Converter Suitable for Renewable Energy-Based MVDC Collection System
Azeem, S. W., Ehab, M., Guerrero, J. M., Wang, B., Mehmood, K., Milyani, A. H., & Azhari, A. A. (2024) · IEEE Access · doi:10.1109/access.2024.3367239 · Cited by 13
Li, M., Jiang, X., Chen, C., Zhang, K., & Xiong, J. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3390421 · Cited by 14
Zhao, S., Li, Z., Chen, Y., Li, P., Zou, X., & Kang, Y. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8558062 · Cited by 13
“Such a hierarchical redundancy strategy is studied in [16].”
BackgroundMethodSelf-citationFault Diagnosis Method of Power Electronic Converter Based on Broad Learning
Han, R., Wang, R., & Zeng, G. (2020) · Complexity · doi:10.1155/2020/7463291 · Cited by 12
“However, this method is sensitive to parameters and is highly susceptible to external interference, so the fault mathematical model is difficult to establish [16, 17].”
MethodPark, C.-H., Seo, I.-K., Negesse, B. B., Yoon, J.-S., & Kim, J.-M. (2021) · Energies · doi:10.3390/en14061607 · Cited by 12
Wang, Z., Yin, X., & Chen, Y. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108048 · Cited by 11
Self-citationKonstantinou, G. S., Ceballos, S., Gabiola, I., Pou, J., Karanayil, B., & Agelidis, V. G. (2017) · Asian Conference on Energy, Power and Transportation Electrification (ACEPT) · doi:10.1109/acept.2017.8168595 · Cited by 11
“A low-power, small-scale system for ship propulsion and ship MVDC grid testing was developed in [17].”
Cui, S., Soltau, N., & Doncker, R. W. D. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095986 · Cited by 10
Xu, Y., Shi, Y., Xiong, Z., & Yang, H. (2023) · Quality and Reliability Engineering International · doi:10.1002/qre.3276 · Cited by 10
“The results show that (1) redundant design effectively improves system availability to meet power supply requirements; (2) in the case of system aging and imperfect repair, redundant configuration and power distribution can significantly improve the availability of power supply to be almost unaffected by aging, and ef…”
BackgroundAN OVERVIEW OF DESIGN, CONTROL, POWER MANAGEMENT, SYSTEM STABILITY AND RELIABILITY IN ELECTRIC SHIPS
Ni, K., Hu, Y., & Xinhua, L. (2017) · Prace Naukowe Uniwersytetu Ekonomicznego we Wrocławiu · doi:10.5277/ped170211 · Cited by 12
“A MMC with hierarchical redundancy ability was designed and implemented for electric ship mediumvoltage DC system in [34].”
MethodInfluentialTian, L., Hongwei, Z., Bin, H., & Yu, Q. (2023) · Journal of the Chinese Institute of Engineers · doi:10.1080/02533839.2023.2262722 · Cited by 9
“It is difficult to establish an accurate fault mathematical model (Gao, Cecati, and Ding 2015; Chen et al. 2016).”
BackgroundTransient skin effect in power electronic applications
Donaghy‐Spargo, C., & Horsfall, A. B. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8132 · Cited by 9
Moghassemi, A., Timilsina, L., Rahman, S. M. I., Arsalan, A., Chamarthi, P. K., Özkan, G., Papari, B., Edrington, C. S., & Zhang, Z. (2024) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec60657.2024.10598932 · Cited by 8
“This shift reduces cable weight, simplifies generator paralleling, and minimizes voltage dips [2].”
BackgroundZhang, Y., Wang, H., Wang, Z., Yang, Y., & Blaabjerg, F. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507408 · Cited by 8
Yang, W., Yao, F., & Zhou, Y. (2022) · Electronics · doi:10.3390/electronics11142193 · Cited by 8
Shah, F. M., Maqsood, S., Damaševičius, R., & Blažauskas, T. (2020) · Electronics · doi:10.3390/electronics9111878 · Cited by 7
Geng, Z., Yang, Y. B., Xiao, Y., Xie, W., & Zhou, G. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3486359 · Cited by 7
Xiao, Q., Jin, Y., Wang, J., Wang, S., Chen, L., Jia, H., Mu, Y., Dragičević, T., & Teodorescu, R. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927316 · Cited by 8
“Cold reserve methods, where reserve SMs are usually bypassed and inserted only when SM fault occurs, are widely adopted in high voltage high power applications [12].”
BackgroundModular multilevel converters: A study on topology, control and applications
Kurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · doi:10.1109/iceee2.2018.8391305 · Cited by 8
“Other applications have been presented in the last three years in the literature such as motor drives [63]–[65], STATCOM [66], [67], PET [68], [69], renewable energy integration containing PV system and wind energy [70]– [74], BES systems [75], [76], active power filter [77] and electric ship implementation [78].”
Wang, L., Bosworth, M., Hauer, J., Soto, D. M., Schoder, K., & Steurer, M. (2019) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2019.8847822 · Cited by 7
“For future naval ship applications the MMC is accelerating the adoption of MVDC with better reliability and high energy conversion performance [3], [4].”
MethodWang, L., Shi, Y., Bosworth, M., Soto, D. M., & Steurer, M. M. (2020) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2020.2997211 · Cited by 7
“Correspondingly, the MMC is also established in medium-voltage (MV) system applications, such as, motor drives [5], Static Synchronous Compensators (STATCOMs) [6], energy storage systems [7], and shipboard power conversion units [8], [9].”
BackgroundA capacitor overvoltage elimination strategy for reduced-voltage-sensor-based MMC
He, R., Jin, Y., Hou, W., Luo, D., & Huang, S. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107181 · Cited by 7
Chen, M., Wang, M., Zhang, D., Chen, Y., & Lu, W. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3131051 · Cited by 7
Self-citationYang, L., Jia, L., Zou, Y., Zhang, M., & Yang, H. (2023) · IET Power Electronics · doi:10.1049/pel2.12475 · Cited by 6
Zhang, F., Zhang, Z., Zhang, Z., Wang, T., Han, J., & Amirat, Y. (2024) · Journal of Marine Science and Engineering · doi:10.3390/jmse12030500 · Cited by 6
Camurça, L., Langwasser, M., & Liserre, M. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124349 · Cited by 6
“, in ships [3] and the new EV charging infrastructure, since it enables compact design and installations [4].”
BackgroundUnruh, R., Lange, J. H., Schafmeister, F., & Böcker, J. (2021) · European Conference on Power Electronics and Applications · doi:10.23919/epe21ecceeurope50061.2021.9570542 · Cited by 8
Analysis and Design of a Modular Self-Balance High-Voltage Input DC–DC Topology
Xiao, Z., He, Z., Guan, R., Li, Z., Xu, Q., Chen, Y., & Luo, A. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3140898 · Cited by 6
Self-citationKumar, V., Singh, S., & Jain, S. (2022) · IETE Journal of Research · doi:10.1080/03772063.2022.2034535 · Cited by 6
“It is reported for a classical flying capacitor (FC) MLI topology by connecting SCR in parallel to the main switch [21], and by adding an external module to each leg of the Modular Multilevel Converters (MMC) [22,23].”
BackgroundFault Tolerant Control for Medium Voltage Hybrid MMC With Cold Reserve Submodules
Hassanifar, M., Ventura, S., Langwasser, M., Amato, D. D., Monopoli, V. G., & Liserre, M. (2024) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg61800.2024.10667457 · Cited by 5
“In [17], both hot and cold reserve SM are added as a redundant SM.”
BackgroundSmall‐signal modelling considering internal perturbations for modular multilevel converters
Song, S., Liu, J., Chen, X., Sheng, J., & Liu, H. (2022) · IET Power Electronics · doi:10.1049/pel2.12402 · Cited by 5
System Control Strategy of an MMC-Based PMSG Rectifier for Ship MVDC Integrated Power System
Li, S., Chen, L., Yang, P., Wang, K., Zheng, Z., & Li, Y. (2019) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2019.8847880 · Cited by 5
“Instead, multilevel converters receive increasing attentions in recent years due to the ever growing demands for high power and high voltage converters [5]–[7].”
BackgroundDirect Multivariable Control of MMC Under Transient Conditions
Dinkel, D., Hillermeier, C., & Marquardt, R. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915449 · Cited by 6
“High power voltage source converters, especially MMC, have become key components for many important future applications [1], [2], [3]: Efficient use of solar and wind power resources, improved grid infrastructure, multiterminal MVDC and HVDC [4], electric ships [5], [6] and others [7].”
BackgroundMutyala, S. N. V., Cvetkovic, I., DiMarino, C., & Boroyevich, D. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948089 · Cited by 5
“Some research [2][3][4] has discussed cold storage redundancy, in which redundant unactive SMs are connected in series to replace faulty SMs.”
BackgroundJiang, D., & Wang, Y. (2023) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2023.039244 · Cited by 5
Geng, Z., Han, M., Xie, W., & Yang, Y. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109970 · Cited by 4
A New Configurable SC-Based Dual Source Inverter Topology With Improved Reliability
Anees, M. A., Mekhilef, S., Siddique, M. D., Mubin, M. B., Seyedmahmoudian, M., & Stojcevski, A. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3584035 · Cited by 4
Hassanifar, M., D’Amato, D., Langwasser, M., & Liserre, M. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3647886 · Cited by 3
“In the work presented in [22], the charging method for the cold reserve SM and the inrush current associated with its uncontrolled charging are not addressed.”
Short Endurance Drive Cycle Analysis of MMC Based Absolute Battery Operated Harbor Vessel
Tummakuri, V., Chelliah, T. R., & Ronanki, D. (2021) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon48115.2021.9589295 · Cited by 3
“In medium voltage DC (MVDC) applications, MMC has precedence over other topologies by its multilevel characteristics, hierarchical redundancy, and fault ride-through operation under submodule (SM) failure [4], [5].”
BackgroundWang, D., Guan, Z., Tian, J., Mao, C., Yang, Y., & Wang, Z. (2022) · IET Power Electronics · doi:10.1049/pel2.12272 · Cited by 4
Yang, X., Zhang, Y., Liu, Y., & Jiang, S. L. (2024) · Electronics · doi:10.3390/electronics13193789 · Cited by 3
Shamshuddin, M. A., Kennel, R. M., & Verdugo, D. (2025) · IEEE Access · doi:10.1109/access.2025.3546880 · Cited by 3
Discontinuous Modulation Strategy for Voltage and Temperature Balancing of MMCs
D’Amato, D., Barros, S. N., Jung, J.-H., & Liserre, M. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977434 · Cited by 3
Lee, S. J., Park, J.-Y., Kim, D., & Cui, S. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11259672 · Cited by 2
“The modular multilevel converter (MMC) is widely adopted in high-voltage direct current (HVDC) and medium-voltage direct current (MVDC) power systems due to its modularity, scalability, and superior waveform quality [1]–[3].”
Device Loading of a Modular Multilevel Converter with Flying Capacitor Submodules
Ronanki, D., & Williamson, S. S. (2018) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2018.8707700 · Cited by 2
“Recently, the application of MMCs in electric transportation systems is continuously growing including electric railway systems, heavy-duty electrified vehicles, electric ship on-board medium-voltage dc power systems, energy storage systems and medium-voltage fast charging infrastructure [3]–[6].”
BackgroundSwitching transient induced skin effect in Packet Energy Transfer systems
Sarkar, T., & Casey, J. (2024) · IEEE SoutheastCon · doi:10.1109/southeastcon52093.2024.10500149 · Cited by 2
“The ever-increasing range of power electronic applications have added new areas like Electric vehicle (EV) charging [1]–[3], renewable energy conversion, industrial processes and High Voltage DC (HVDC) power transmission [4]–[7] over the last couple of decades.”
BackgroundMoghassemi, A., Timilsina, L., Rahman, S. M. I., Arsalan, A., Muriithi, G., Buraimoh, E., Özkan, G., Papari, B., Edrington, C. S., Zhang, Z., et al. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3559049 · Cited by 2
Multi-layer fault-tolerant control of MMC for shipboard MVDC power system
Hong, L., Xu, Q., Luo, A., He, Z., Chen, Y., & Yue, Y. (2018) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2018.8398050 · Cited by 2
“However, most of the tolerant strategies mentioned above require complex modulation reconfiguration and do not make full use of the redundant SMs in the normal operation of the MMC.”
BackgroundInfluentialSelf-citationFault-Tolerance Capabilities in a Switched Capacitor Multilevel Inverter Topology
Debela, T., & Singh, J. (2022) · IEEE Silchar Subsection Conference (SILCON) · doi:10.1109/silcon55242.2022.10028947 · Cited by 1
An Overview of Power Electronics Techniques in Electric Systems for Transport Applications
(2017) · International Journal of Research Studies in Electrical and Electronics Engineering · doi:10.20431/2454-9436.0303003 · Cited by 2
“In addition, the fundamental frequency modulation technique in [61] was applied to minimize the switching times of each SM for further alleviation of the leakage current.”
MethodArslan, A. O., Kurtoğlu, M., Eroğlu, F., & Vural, A. M. (2019) · Journal of Power Electronics · doi:10.6113/jpe.2019.19.4.922 · Cited by 1
A Novel Single-Clamped Hybrid-Arm MMC with DC-FRT and STATCOM Capability
Inwumoh, J., Baguley, C., & Gunawardane, K. (2022) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec55080.2022.10058211 · Cited by 1
“The MMC-HVDC system exhibits high scalability, improved efficiency, and reduced harmonic distortion [1]−[2].”
Background
Metadata
- Authors
- Chen, Y., Li, Z., Zhao, S., Wei, X., & Kang, Y.
- Affiliations
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology (CN)
- State Grid Corporation of China (China) (CN)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-03
- Volume
- 5
- Issue
- 1
- Pages
- 189-202
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2550943922
- Cited by
- 111
- References
- 35
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 12 · 2023: 9 · 2022: 16 · 2021: 12 · 2020: 15 · 2019: 13 · 2018: 15 · 2017: 8
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- Funders
- Science and Technology Funds of State Grid Preliminary Research for High Voltage DC/DC Converters Suitable for DC Grids
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, electric ships, MVDC
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.