Design and Implementation of a Modular Multilevel Converter With Hierarchical Redundancy Ability for Electric Ship MVDC System
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Modular multilevel converter (MMC) can be considered as a promising candidate for modern electric ship medium-voltage direct current (MVDC) power system due to its high-voltage quality, low switching loss, good expansibility, and good redundancy. As the voltage level in MVDC is much lower than that in high-voltage direct current case, the number of submodules (SMs) of MMC in MVDC system is also much less. Therefore, the SM failure will have more significant effect on the safety operation. Since uninterrupted operation is one of the most important requirements in electric ship application, the special redundancy design for MMC is required. This paper thus proposes an MMC system with hierarchical redundancy ability, aiming to guarantee the ride-through operation under SM failure. The “hot-reserved” and “cold-reserved” SMs are prepared in the MMC by compromising the faulty SM number, voltage and current stress of SMs, SM power loss, and so on, and the hierarchical redundancy strategy is divided into several progressive layers to ride through the SM failure in different cases. The pretreatment units are designed to realize the proposed hierarchical redundant strategy smoothly, and without changing the existent modulation and sort-and-selection strategies designed for normal condition. The proposed design is explained in this paper, and verified by a three-phase MMC simulation and a single-phase MMC prototype.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multicarrier PWM strategies for multilevel inverters
McGrath, B. P., & Holmes, D. G. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801073 · Cited by 1,232 · cited 1×
“on the method [35], aiming to generate the proper SM number signal nL that needs to be driven by “1”; however, its rule has been extended to adapt to the redundancy purpose.”
MethodFault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“battery [4], [16], [17], the MMC can obtain the energy storage ability; and if the active power filter is added to”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329 · cited 1×
“In [18] and [19], SM fault is detected by sliding mode observer.”
BackgroundSon, G. T., Lee, H.-J., Nam, T. S., Chung, Y.-H., Lee, U.-H., Baek, S.-T., Hur, K., & Park, J.-W. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2190530 · Cited by 290 · cited 3×
“In [23]–[26], the “hot-reserved” and “cold-reserved” SMs were prepared.”
BackgroundOperation of a Medium-Voltage Drive Under Faulty Conditions
Rodriguez, J., Hammond, P. W., Pontt, J., Musalem, R., Lezana, P., & Escobar, M. J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
Fault Detection and Localization Method for Modular Multilevel Converters
Deng, F., Chen, Z., Khan, M. R., & Zhu, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2348194 · Cited by 266 · cited 1×
“battery [4], [16], [17], the MMC can obtain the energy storage ability; and if the active power filter is added to”
BackgroundModular multilevel inverter: pulse width modulation and capacitor balancing technique
Adam, G. P., Anaya-Lara, O., Burt, G. M., Telford, D., Williams, B. W., & McDonald, J. R. (2010) · IET Power Electronics · doi:10.1049/iet-pel.2009.0184 · Cited by 248
Shao, S., Watson, A. J., Clare, J. C., & Wheeler, P. W. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2462717 · Cited by 182 · cited 1×
“Reference [20] employed a Kalman filter to detect the fault.”
MethodEnhancing the reliability of modular medium-voltage drives
Hammond, P. W. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803172 · Cited by 176 · cited 1×
“In [23]–[26], the “hot-reserved” and “cold-reserved” SMs were prepared.”
Energy-balancing Control Strategy for Modular Multilevel Converters Under Submodule Fault Conditions
Hu, P., Jiang, D., Zhou, Y., Liang, Y., Guo, J., & Lin, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284919 · Cited by 148 · cited 1×
“Besides, the output port of the SM is associated with a mechanical switch Q [23], [30], [31], and it can be turned ON or OFF for redundancy purpose.”
BackgroundYang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2477476 · Cited by 140 · cited 2×
“In [18] and [19], SM fault is detected by sliding mode observer.”
BackgroundMethodChoudhury, A., Pillay, P., & Williamson, S. S. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2310140 · Cited by 135 · cited 1×
“Conventional two-level dc–ac converter [8] is not easy to handle high power and voltage, and also needs bulky filters to obtain the satisfactory output voltage.”
BackgroundA Resilient Framework for Fault-Tolerant Operation of Modular Multilevel Converters
Ghazanfari, A., & Mohamed, Y. A. I. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2516968 · Cited by 128 · cited 1×
“A clustering algorithm-based method and a calculated capacitance-based method were proposed to diagnose fault for the MMC in [21].”
MethodReconfiguration of Carrier-Based Modulation Strategy for Fault Tolerant Multilevel Inverters
Ma, M., Hu, L., Chen, A., & He, X. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904249 · Cited by 123
Li, B., Zhang, Y., Yang, R., Xu, R., Xu, D., & Wang, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2392778 · Cited by 116 · cited 1×
“In [24], no extra SMs are prepared but once some SMs were faulty and bypassed, the new capacitor voltage references for SMs were calculated to adapt to the new situation, and the impacts of the faulty modules were thus alleviated.”
BackgroundOptimized Control Strategy Based on Dynamic Redundancy for the Modular Multilevel Converter
Liu, G., Xu, Z. G., Xue, Y., & Tang, G. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2305663 · Cited by 115 · cited 2×
“Reference [22] proposed a fault detection method by establishing state observers.”
MethodControl method for cascaded H-bridge multilevel inverter with faulty power cells
Wei, S., Wu, B., Fahai, L., & Sun, X. (2003) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2003.1179224 · Cited by 102
Najjar, M., Moeini, A., Bakhshizadeh, M. K., Blaabjerg, F., & Farhangi, S. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2555995 · Cited by 97 · cited 1×
“Neutral point clamping (NPC) [9], flying capacitor (FC) [10], cascaded topologies [11], and modular multilevel converter (MMC) [4], [12], [13] are the possible choices for the MVDC power system.”
BackgroundEvaluation of Semiconductor Based Methods for Fault Isolation on High Voltage DC Grids
Hajian, M., Jovcic, D., & Wu, B. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2238260 · Cited by 96 · cited 1×
“reliability of the overall system are enhanced [1], [2], [4], [5].”
BackgroundAssessment of Fault Tolerance in Modular Multilevel Converters With Integrated Energy Storage
Soong, T., & Lehn, P. W. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2477834 · Cited by 83 · cited 1×
“pack IGBT is used, the bypassing can be automatically realized once it is faulty [14], [15].”
MethodAll-electric ships—A review of the present state of the art
Thongam, J. S., Tarbouchi, M., Okou, A. F., Bouchard, D., & Beguenane, R. (2013) · 2013 Eighth International Conference and Exhibition on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2013.6521626 · Cited by 72 · cited 1×
“5) And finally, if SM4 is faulty and bypassed, b = 3, I [1] = 6, I [2] = 5, and I [3] = 4 are rewritten by PU1.”
BackgroundSadigh, A. K., Dargahi, V., Abarzadeh, M., & Dargahi, S. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2013.0071 · Cited by 68 · cited 1×
“Neutral point clamping (NPC) [9], flying capacitor (FC) [10], cascaded topologies [11], and modular multilevel converter (MMC) [4], [12], [13] are the possible choices for the MVDC power system.”
BackgroundExperiment and Simulation of a Modular Push–Pull PWM Converter for a Battery Energy Storage System
Hagiwara, M., & Akagi, H. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2274471 · Cited by 65 · cited 1×
“pack IGBT is used, the bypassing can be automatically realized once it is faulty [14], [15].”
MethodA modulation reconfiguration based fault-tolerant control scheme for modular multilevel converters
Shen, K., Xiao, B., Mei, J., Tolbert, L. M., Wang, J., Cai, X., & Ji, Y. (2013) · 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2013.6520766 · Cited by 58 · cited 1×
“Besides, the output port of the SM is associated with a mechanical switch Q [23], [30], [31], and it can be turned ON or OFF for redundancy purpose.”
BackgroundPower Flow and Generator-Converter Schemes Studies in Ship MVDC Distribution Systems
Su, C., Lin, K.-L., & Chen, C.-J. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2463795 · Cited by 50 · cited 7×
“4) If SM5 is further faulty and bypassed, b = 2, I [1] = 1, and I [2] = 5 are rewritten by PU1.”
BackgroundInfluentialGerber, D., Guillod, T., Leutwyler, R., & Biela, J. (2013) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2013.2280379 · Cited by 45 · cited 1×
“Neutral point clamping (NPC) [9], flying capacitor (FC) [10], cascaded topologies [11], and modular multilevel converter (MMC) [4], [12], [13] are the possible choices for the MVDC power system.”
BackgroundChen, Y., Cui, Y., Wang, X., Wei, X., & Kang, Y. (2016) · IET Power Electronics · doi:10.1049/iet-pel.2015.0522 · Cited by 39
Self-citationSteurer, M., Bogdan, F., Bosworth, M., Faruque, O., Hauer, J., Schoder, K., Sloderbeck, M., Soto, D. M., Sun, K., Winkelnkemper, M., et al. (2015) · IEEE International Conference on Electrical Systems for Aircraft, Railway, Ship Propulsion and Road Vehicles & International Transportation Electrification Conference (ESARS-ITEC) · doi:10.1109/esars.2015.7101535 · Cited by 32 · cited 1×
“MVDC case is relatively small (usually four to ten SMs) [4], [32], [33].”
BackgroundSun, K., Soto, D. M., Steurer, M. M., & Faruque, O. (2015) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2015.7157857 · Cited by 29 · cited 2×
“MVDC case is relatively small (usually four to ten SMs) [4], [32], [33].”
BackgroundComparison of control schemes for multilevel inverter with faulty cells
Wei, S., Wu, B., Rizzo, S. C., & Zargari, N. R. (2005) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2004.1431859 · Cited by 22 · cited 1×
“phases’ modulation references were increased in proper way, so that the line voltages were still unchanged [27]–[33].”
BackgroundMo, R., Li, R., & Li, H. (2015) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2015.7157871 · Cited by 19 · cited 5×
“battery [4], [16], [17], the MMC can obtain the energy storage ability; and if the active power filter is added to”
BackgroundInfluentialModular multilevel converter based medium voltage DC amplifier for ship board power system
Vechalapu, K., & Bhattacharya, S. (2015) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2015.7223098 · Cited by 7 · cited 4×
“4) If SM5 is further faulty and bypassed, b = 2, I [1] = 1, and I [2] = 5 are rewritten by PU1.”
BackgroundInfluentialIEEE Electric Ship Technologies initiative
Khersonsky, Y., Hingorani, N. G., & Peterson, K. L. (2009) · Record of conference papers/Record of conference papers - Petroleum and Chemical Industry Conference · doi:10.1109/pcicon.2009.5297177 · Cited by 7
Lenz, K., Jerinic, V., & Hinken, R. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7467888 · Cited by 3 · cited 1×
“Neutral point clamping (NPC) [9], flying capacitor (FC) [10], cascaded topologies [11], and modular multilevel converter (MMC) [4], [12], [13] are the possible choices for the MVDC power system.”
BackgroundZero voltage switching Dual Neutral Point Clamped dc-dc converter
Jacoboski, M. J., & Heldwein, M. L. (2015) · IEEE Brazilian Power Electronics Conference and Southern Power Electronics Conference · doi:10.1109/cobep.2015.7420152 · Cited by 2 · cited 2×
“Among them, the circuit configurations of NPC and FC will become complicated with the voltage level increasing, since more capacitors and diodes are required, and these capacitors will be suffered from the voltage balancing problem; the cascaded topology requires a lot of independent dc sources, which will complicate…”
Background
Cited by
Modular Multilevel Converters for Transportation Electrification: Challenges and Opportunities
Ronanki, D., & Williamson, S. S. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2792330 · Cited by 345
“Recently, the MMC has gained attention in the field of transportation due to aforementioned features and become promising for electric railway traction [13], [14], railway power supplies [15], [16], battery energy storage systems (ESSs) [17], [18], emerging electric ship [19], [20], battery charging infrastructure [21…”
BackgroundInfluentialModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“Designing the on-board converter with redundant submodules, the converter reliability is improved [153].”
BackgroundReliability and Cost based Redundancy Design for Modular Multilevel Converter
Tu, P., Yang, S., & Wang, P. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793263 · Cited by 199
Recent Advancements in Submodule Topologies and Applications of MMC
Ali, S., Ling, Z., Tian, K., & Huang, Z. M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2990689 · Cited by 119
“The MV-dc shipboard systems are better than the ac system because they offer good power quality, high transmission ability, integration of RES, and high efficiency by removing energy conversion devices [233]–[235].”
BackgroundA New Single-Phase Five-Level Inverter Topology for Single and Multiple Switches Fault Tolerance
Aly, M., Ahmed, E. M., & Shoyama, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2792146 · Cited by 111
“Another solution is to add an extra module in each leg of the modular multilevel inverters [17], [18].”
Background
Metadata
- Authors
- Chen, Y., Li, Z., Zhao, S., Wei, X., & Kang, Y.
- Affiliations
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology (CN)
- State Grid Corporation of China (China) (CN)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-03
- Volume
- 5
- Issue
- 1
- Pages
- 189-202
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2550943922
- Cited by
- 111
- References
- 35
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 12 · 2023: 9 · 2022: 16 · 2021: 12 · 2020: 15 · 2019: 13 · 2018: 15 · 2017: 8
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- Funders
- Science and Technology Funds of State Grid Preliminary Research for High Voltage DC/DC Converters Suitable for DC Grids
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, electric ships, MVDC
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.