Assessment of Fault Tolerance in Modular Multilevel Converters With Integrated Energy Storage
The DOI matches its Crossref record.
Abstract
Energy storage (ES) integration into the grid is typically achieved using a two- or three-level dc/ac converter with ES interfaced directly to the inverter's dc link or through a dc/dc converter. In both cases, long-series connected strings of batteries are required to efficiently maintain the necessary dc-link voltage. Such configurations are susceptible to reliability issues, as shutdown of a battery string due to individual battery failure, overheating, or overcharging/discharging results in loss of a large fraction of ES capacity. To increase the reliability of an ES system, shorter strings of batteries are preferable. In this study, the ES is subdivided into many banks of short-series strings, which are integrated into the submodules of a modular multilevel converter (MMC). To further enhance the reliability, the MMC should also be unaffected by an ES bank shutdown. This paper investigates the robustness of the MMC to ES bank failure by assessing the power balance between submodules when a subset of ES banks is not operational. The analysis concludes that as many as 33% of ES banks may be shutdown without affecting MMC power exchange with the grid, and is supported with both simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Power Electronics Technology for Large-Scale Renewable Energy Generation
Blaabjerg, F., Yang, Y., Kim, K. A., & Rodriguez, J. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3253165 · Cited by 330
Reliability and Cost based Redundancy Design for Modular Multilevel Converter
Tu, P., Yang, S., & Wang, P. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793263 · Cited by 199
Chen, Y., Li, Z., Zhao, S., Wei, X., & Kang, Y. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2632858 · Cited by 111
“pack IGBT is used, the bypassing can be automatically realized once it is faulty [14], [15].”
MethodChang, F., Ilina, O., Lienkamp, M., & Voss, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2854756 · Cited by 111
“verters, different algorithms to further utilize the advantages of such topologies, such as harmonic reduction [79], SOC balancing [48], [50], fault-tolerance operation [70], [80], etc.”
BackgroundXavier, L. S., Amorim, W. C. S., Cupertino, A. F., Mendes, V. F., do Boaventura, W. C., & Pereira, H. A. (2019) · BMC Energy · doi:10.1186/s42500-019-0006-5 · Cited by 61
Metadata
- Authors
- Soong, T., & Lehn, P. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-06
- Volume
- 31
- Issue
- 6
- Pages
- 4085-4095
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2240552685
- Cited by
- 83
- References
- 0
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Fault Tolerance in Modular Multilevel Converters With Integrated Energy Storage. https://app.cochat.ai/papers/10.1109/tpel.2015.2477834
- The paper
- Soong, T., & Lehn, P. W. (2016). Assessment of Fault Tolerance in Modular Multilevel Converters With Integrated Energy Storage. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2015.2477834
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.