A Medium-Voltage Medium-Frequency Isolated DC–DC Converter Based on 15-kV SiC MOSFETs
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this paper, a novel isolated dc-dc converter topology for medium-voltage (MV) applications is proposed by combining the advantages of resonant converters and dual active bridge (DAB) converters. In normal load scenario, this converter operates in an open loop resonant mode with a fixed switching frequency equals to the resonant frequency of the series resonant tank. Thus, zero voltage turn on at primary side and zero current turn off at secondary side are secured from zero to full load. When overload happens, the resonant capacitors will be clamped to the output voltage by the additional paralleled diodes. The proposed converter automatically switches to resonant and DAB mixed operation mode; therefore, the resonant current is naturedly limited. With zero to full load range soft switching and fast overload protection, the proposed topology is especially suitable for MV medium frequency applications utilizing high-voltage SiC MOSFETs. The converter operation modes are analyzed using time-domain waveforms and graphical state trajectory to derive the quantitative relationship between duty cycle, output voltage, and the overload current. Based on these relationships, a predictive duty cycle control is proposed to further limit the overload current of the resonant tank by sensing the output voltage. Combing the proposed topology and the predictive control, cycle-by-cycle overload and short-circuit protections are achieved. To fully utilize the capability of the 15-kV SiC MOSFET, magnetizing inductance, dead time, MV transformer, and resonant components are optimized with the operating range of 6-12 kV and 20-100 kHz. An experimental prototype running at 6 kV and 40 kHz is successfully tested with peak efficiency exceeding 98%. Test waveforms at no load and 10-kW full load validate the zero to full load range soft switching capability. Short circuit protection test demonstrates a 25-us overload protection speed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463
Self-citationReview of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Self-citationGuan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Design and Experimental Testing of a Resonant DC–DC Converter for Solid-State Transformers
Ortiz, G., Leibl, M. G., Huber, J. E., & Kolar, J. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2637827 · Cited by 143
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“rectangular modulation [75], [99], [111], [113].”
Background99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886139 · Cited by 315
Power Semiconductor Devices for Smart Grid and Renewable Energy Systems
Huang, A. Q. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2687701 · Cited by 295
Self-citationIsolated and Nonisolated DC-to-DC Converters for Medium-Voltage DC Networks: A Review
Alhurayyis, I., Elkhateb, A., & Morrow, J. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3028057 · Cited by 224
15 kV SiC MOSFET: An Enabling Technology for Medium Voltage Solid State Transformers
FREEDM Systems Center, N. C. S. U., & Huang, A. Q. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00012 · Cited by 182
Self-citation
Metadata
- Authors
- Wang, L., Zhu, Q., Yu, W., & Huang, A. Q.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-03
- Volume
- 5
- Issue
- 1
- Pages
- 100-109
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2565534008
- Cited by
- 116
- References
- 5
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Medium-Voltage Medium-Frequency Isolated DC–DC Converter Based on 15-kV SiC MOSFETs. https://app.cochat.ai/papers/10.1109/jestpe.2016.2639381
- The paper
- Wang, L., Zhu, Q., Yu, W., & Huang, A. Q. (2017). A Medium-Voltage Medium-Frequency Isolated DC–DC Converter Based on 15-kV SiC MOSFETs. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2016.2639381
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.