Analog-to-Information and the Nyquist Folding Receiver
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Recovering even a small amount of information from a broadband radio frequency (RF) environment using conventional analog-to-digital converter (ADC) technology is computationally complex and presents significant challenges. For sparse or compressible RF environments, an alternate approach to conventional sampling is analog-to-information (A2I) to enable sub-Nyquist rate sampling based on compressive sensing (CS) principles. This paper presents the Nyquist Folding Receiver (NYFR), an efficient A2I architecture that folds the broadband RF input prior to digitization by a narrowband ADC. The folding is achieved by undersampling the RF spectrum with a stream of short pulses that have a phase modulated sampling period. The undersampled signals then fold down into a low pass interpolation filter. The pulse sample time modulation induces a corresponding phase modulation on the received signals that is scaled by an integer modulation index that varies with the Nyquist zone (i.e., fold number), allowing the signals to be separated based on the measured modulation index. Unlike many schemes motivated by CS that randomize the RF prior to digitization, the NYFR substantially preserves signal structure. This enables information recovery with very low computational complexity algorithms in addition to traditional CS reconstruction techniques. The paper includes a comparison of seven other A2I architectures with the NYFR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analog-to-digital converter survey and analysis
Walden, R. H. (1999) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.761034 · Cited by 2,186
Beyond Nyquist: Efficient Sampling of Sparse Bandlimited Signals
Tropp, J. A., Laska, J. N., Duarte, M. F., Romberg, J. K., & Baraniuk, R. G. (2010) · IEEE Transactions on Information Theory · doi:10.1109/tit.2009.2034811 · Cited by 1,089
Photonic analog-to-digital converters
Valley, G. C. (2007) · Optics Express · doi:10.1364/oe.15.001955 · Cited by 784
A Nyquist folding analog-to-information receiver
Fudge, G. L., Bland, R. E., Chivers, M. A., Ravindran, S., Haupt, J., & Pace, P. E. (2008) · 2008 42nd Asilomar Conference on Signals, Systems and Computers · doi:10.1109/acssc.2008.5074464 · Cited by 76 · cited 2×
“1 (see [10] for a more detailed derivation).”
BackgroundSelf-citationPace, P. E., Kusmanoff, A., & Fudge, G. L. (2009) · 2009 Conference Record of the Forty-Third Asilomar Conference on Signals, Systems and Computers · doi:10.1109/acssc.2009.5470156 · Cited by 11
Self-citation
Cited by
Parameter estimation of LFM signals intercepted by a composite local oscillation SNYFR
Li, T., Fan, X., Zhu, Q., & Chen, Z. (2017) · 2017 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS) · doi:10.1109/ispacs.2017.8266510 · Cited by 9
Liu, X., Li, T., Fan, X., & Chen, Z. (2019) · Sensors · doi:10.3390/s19061477 · Cited by 8
Parameter Estimation of SAR Signal Based on SVD for the Nyquist Folding Receiver
Li, T., Zhu, Q., & Chen, Z. (2018) · Sensors · doi:10.3390/s18061768 · Cited by 8
Metadata
- Authors
- Maleh, R., Fudge, G. L., Boyle, F. A., & Pace, P. E.
- Venue
- IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Published
- 2012-09
- Volume
- 2
- Issue
- 3
- Pages
- 564-578
- ISSN
- 2156-3357 (ISSN-L)
- 2156-3365
- OpenAlex
- W2001992125
- Cited by
- 91
- References
- 5
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.