Smart Bandage With Wireless Strain and Temperature Sensors and Batteryless NFC Tag
Open accessAbstract
This article presents a smart bandage with wireless strain and temperature sensors and a batteryless near-field communication (NFC) tag. Both sensors are based on conductive poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) polymer. The highly sensitive strain sensor consists of a microfluidic channel filled with PEDOT:PSS in Polydimethylsiloxane (PDMS) substrate. The strain sensor shows 3 order (~1250) increase in the resistance for 10% strain and considerably high gauge factor (GF) of~12 500. The sensor was tested for~30% strain, which is more than typical stretching of human skin or body parts such as chest expansion during respiration. The strain sensor was also tested for different bending and the electrical resolution was~150% per degree of free bending and~12k% per percentage of stretching. The resistive temperature sensor, fabricated on a Polyvinyl Chloride (PVC) substrate, showed a~60% decrease in resistance when the temperature changed from 25 °C to 85 °C and a sensitivity of~1% per °C. As a proof of concept, the sensors and NFC tag were integrated on wound dressing to obtain wearable systems with smart bandage form factor. The sensors can be operated and read from distance of 25 mm with a user-friendly smartphone application developed for powering the system as well as real-time acquisition of sensors data. Finally, we demonstrate the potential use of smart bandage in healthcare applications such as assessment of wound status or respiratory diseases, such as asthma and COVID-19, where monitoring via wearable strain (e.g., respiratory volume) and temperature sensors is critical.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · cited 1× · see citing works
“As a result, several types of wearable sensors tethered to the patients via cables have been explored as an alternative to the traditional lab-based measurement systems [7]–[9].”
BackgroundLab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725 · see citing works
Sim, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1806949 · Cited by 491 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A Wearable Skin Temperature Monitoring System for Early Detection of Infections
Huan, J., Bernstein, J. S., Difuntorum, P., Masna, N. V. R., Gravenstein, N., Bhunia, S., & Mandal, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3131500 · Cited by 27 · see citing works
- Authors
- Escobedo, P., Bhattacharjee, M., Nikbakhtnasrabadi, F., & Dahiya, R.
- Affiliations
- University of Glasgow (GB)
- Indian Institute of Science Education and Research, Bhopal (IN)
- Venue
- IEEE Internet of Things Journal
- Published
- 2021-03-15
- Volume
- 8
- Issue
- 6
- Pages
- 5093-5100
- ISSN
- 2327-4662 (ISSN-L)
- 2372-2541
- OpenAlex
- W3114264663
- Cited by
- 209
- References
- 3
- Citations by year
- 2026: 16 · 2025: 35 · 2024: 31 · 2023: 36 · 2022: 58 · 2021: 33
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Internet of Things Journal (publishedVersion, cc-by)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion, cc-by-sa)
- Institutional Repository of the University of Granada (University of Granada) (submittedVersion, cc-by-nc-nd)
- Funders
- Engineering and Physical Sciences Research Council (EPSRC) through Engineering Fellowship for Growth (EP/R029644/1)
- North West Centre for Advanced Manufacturing (NW CAM) Project through the European Union’s INTERREG VA Programme
- Special EU Programmes Body (H2020-Intereg-IVA5055)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- smart bandages, strain sensors, temperature sensors, near field communication, PEDOT:PSS, conducting polymers, microfluidic channels, wearable sensors, wound monitoring, respiratory monitoring, asthma, COVID-19 pandemic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review